Leak test and function test
If gas escapes
Checking the gas
connection
Checking the
burner nozzles
22
Make sure that no sparks are generated. Do not
use fire or naked flames.
There is a risk of explosion.
Check the tightness with suitable foam.
Close the locking device.
Ventilate the room sufficiently.
Check the gas and nozzle connections once more.
Repeat the leak test.
The leak test should be carried out by two persons as
follows.
1.
Open the locking device for the gas connection.
2.
Moisten the area around the gas connection with
foam.
If the foam dissolves or gas escapes, see "If gas
escapes".
Also check the side closed with a blind plug for leaks.
1.
Open the locking device for the gas connection.
Check each nozzle individually for leaks.
2.
To do this, hold the opening of the burner nozzle
shut with a finger or carefully lock it using a special
device.