GENERAL INFORMATION
The RTY Series uses a magnetically biased, Hall-effect
integrated circuit (IC) to sense rotary movement of the actuator
shaft over a set operating range. Rotation of the actuator shaft
changes a magnet's position relative to the IC. The resulting
flux density change is converted to a linear output.
Table 1. Specifications
Characteristic
Supply voltage
Supply current
Supply current (during output to ground short)
Output
Output signal delay
Overvoltage protection
Reverse polarity protection
Output to ground short circuit protection
Output load resistance (pull down to ground)
EMI:
radiated immunity
conducted immunity
EMC
Operating temperature range
Storage temperature range
Ingress protection
Expected life
Media compatibility
Housing material
Shock
Vibration
Resolution
Termination
Mechanical end stop
Approvals
Figure 1. Mounting Dimensions (For Reference Only: mm/[in].)
32,0 DIA.
[1.25]
22,0
[0.87]
5,35 DIA.
[0.21]
9,5
[0.37]
26,0
[1.02]
Sensing and Control
0.5 V to 4.5 V ratiometric
100 mA BCI per ISO11452-4
5,9
[0.23]
8,3
[0.33]
37
15,50 DIA.
[1.46]
[0.61]
4,60
[0.18]
55
[2.17]
13,8
[0.54]
15,6
[0.61]
Pin 1
2,0 DIA.
[0.078]
Pin 2
Pin 3
6 DIA.
[0.24]
4,12
[0.16]
25
[0.98]
MOUNTING INFORMATION
Mount the sensor using the two easily accessible mounting
holes and non-magnetic stainless steel M5 screws with flat
washers. Mounting screw tightening torque is 2,5 N m
±0,5 N m [22.1 in lb ±4.4 in lb]. In harsh applications, treat the
screw threads with a suitable thread locking compound.
Parameter
LV (Low Voltage)
5 ±0.5 Vdc
20 mA max.
25 mA max.
4 ms typ.
10 Vdc
-10 Vdc
continuous
10 kOhm
100 V/m from 200 MHz to 1000 MHz per ISO11452-2
from 1 MHz to 200 MHz
exceeds CE requirements
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
IP67 according to DIN 40050
35 M cycles
heavy transportation fluids
PBT plastic
50 G peak
20 G peak tested from 10 Hz to 2000 Hz
12 bit
AMP super seal connector
B
0
A
C
0 /2
0 /2
36,4
[1.43]
HV (High Voltage)
10 Vdc to 30 Vdc
32 mA max.
47 mA max.
0.5 V to 4.5 V non-ratiometric
-30 Vdc
100 mA BCI per ISO11452-4
from 1 MHz to 400 MHz
no
CE
A = Left output: 0.5 Vdc
B = Zero reference
C = Right output: 4.5 Vdc
Pinout
N
(North
(European)
American)
Pin 1 = VCC
Pin 1 = GND
Pin 2 = GND
Pin 2 = VCC
Pin 3 = Output
Pin 3 = Output
NOTICE
Ferrous or magnetic material
within a 75 mm [2.95 in] radius
from sensor center may affect
sensor performance.
E
loading

Summary of Contents for Honeywell RTY Series

  • Page 1 GENERAL INFORMATION MOUNTING INFORMATION The RTY Series uses a magnetically biased, Hall-effect Mount the sensor using the two easily accessible mounting integrated circuit (IC) to sense rotary movement of the actuator holes and non-magnetic stainless steel M5 screws with flat shaft over a set operating range.
  • Page 2: Personal Injury

    Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
  • Page 3 The output of the IC is converted to a linear output Sensing and Control (S&C) for your Hall-effect rotary position up to 360 degrees of travel. Honeywell S&C seals the IC together sensor needs. These sensors vary output voltage or current in with conditioning and protection circuitry and two permanent response to changes in a magnetic field —...
  • Page 4 Hall-Effect Rotary Position Sensors Line Guide More are turning to Honeywell, for more value. Honeywell S&C RTY and RPN Series Hall-effect rotary position sensors respond Hall-Effect Rotary to the presence or to the Position Sensors RTy Series interruption of a magnetic...
  • Page 5 Hall-Effect Rotary Position Sensors RPn Series HRS100 Series 50° (±25°), 60° (±30°), 70° (±35°), 90° (±45°), 120° (±60°), Sensing range 90° ±2°, 180° ±2° 180° (±90°), 270° (±135°), 360° (±180°) Redundant version Input voltage 5 Vdc, 8 to 30 Vdc, 10 Vdc to 30 Vdc 5 Vdc ±10% 0.25 V to 4.75 V, 0.5 V to 4.5 V, 1 V to 9 V, 3 V to 5 V, 4.5 V to 5% to 95% of applied Vdd, approx.
  • Page 6 Honeywell web site, it is up to the Honeywell’s standard product warranty customer to determine the suitability of the applies unless agreed to otherwise by product in the application.
  • Page 7: Potential Applications

    Hall-Effect Rotary Position Sensors DESCRIPTION The RTY Series Hall-Effect Rotary Position Sensors provide Eight operating ranges (50°, 60°, 70°, 90°, 120°, 180°, 270° angle monitoring in harsh transportation and industrial and 360°) are tolerant to over-travel and allow use in most applications at a competitive cost.
  • Page 8 RTY Series Table 1. Specifications Characteristic Parameter LV (Low Voltage) HV (High Voltage) Supply voltage 5 ±0.5 Vdc 10 Vdc to 30 Vdc Supply current 20 mA max. 32 mA max. Supply current (during output to ground short) 25 mA max.
  • Page 9 0º position for its ideal value at 25 °C ±5 °C. Accuracy is valid only when the sensor output is correct at 0º position for its ideal value in the application. 360° (±180°) -180 +180 Actuator Position ( °) Honeywell Sensing and Control...
  • Page 10 Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6355-2828 our literature and the Honeywell web site, it is up to the +65 6445-3033 Fax customer to determine the suitability of the product in the Europe +44 (0) 1698 481481 application.