P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — Document information File name 04-3598_ABB_OPM_PVA11 1-3kVA-T_G2_EN_REV-D UPS model PowerValue 11 RT G2 1-3 kVA B/S Date of issue 30.07.2018 Issued by Product Marketing Checked by...
1 S A F E T Y — 1 Safety READ THIS IMPORTANT SAFETY INSTRUCTION CHAPTER BEFORE READING THE OPERATING MANUAL. — 1 1 Safety instructions 1 1 1 Safety symbols and warnings The following symbols are used in this manual. The list below explains each symbol.
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S 1 1 2 Installation 1 1 3 Operation — 01 The air flow diagram Always follow the precautions and instructions FOR SAFETY REASONS, DO NOT described in this manual.
1 S A F E T Y 1 1 4 Maintenance, servicing, and faults 1 1 5 Transport TRANSPORT THE UPS ONLY IN THE THE UPS OPERATES WITH HAZARDOUS ORIGINAL PACKAGING (TO PROTECT VOLTAGES. AGAINST SHOCK AND IMPACT). WARNING DANGER CAUTION—RISK OF ELECTRIC SHOCK.
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — 1 2 UPS disposal and recycling 1 2 1 For professional users in the European Union 1 2 2 For disposal in countries outside of the European Union THE CROSSED –OUT WHEELED BIN SYMBOL ON THE PRODUCT(S) AND / OR...
2 D E S C R I P T I O N S — 2 Descriptions — 2 1 Panel descriptions 2 1 1 Display panel — 02 The display panel The PowerValue 11T G2 1-3 kVA display panel is shown below.
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S 2 1 3 LCD description — 03 The LCD display — LCD idle function: If you enable LCD background idle function when UPS standby mode is turned off, the LCD background will be turned off within 5 seconds.
3 G E T T I N G S TA R T E D — 3 Getting started — 3 1 Unpacking the UPS 3 1 1 Inspection — 04 Unpacking DISCARD OR RECYCLE THE PACKAGING IN Inspect the packaging and its contents for the system A RESPONSIBLE MANNER OR STORE IT damage.
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — 3 2 Connection — 3 2 1 UPS input connection — Table 6: Connecting output and ground 05 Output If the UPS is connected via the power cord, use a connection wires to terminal block...
3 G E T T I N G S TA R T E D — When using standard ABB EBMs, connect them 06 UPS Connect to EBM according to Figure 6. WARNING—THE OUTPUT SOCKETS OF THE UPS SYSTEM MAY STILL HAVE LIVE...
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — 3 3 Battery 3 3 1 Battery recharge 3 3 2 Test function Fully charge the UPS system’s external batteries Test function means checking the UPS system’s by leaving the UPS system connected to the battery performance by pressing the On-Switch for...
3 G E T T I N G S TA R T E D — 3 6 Alarm mute function 3 6 1 Battery mode 3 6 5 Alarm indicators To mute the audio alarm in battery mode, press The audio alarm has a series of beeps based the ON button continuously for 1 second.
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — 4 Operation — 4 1 Operating modes for all models 4 1 1 Operating modes and strings — Fault String 07 The line mode Different messages/strings are displayed on...
4 O P E R AT I O N 4 1 4 Battery mode (bATT) 4 1 7 Emergency Power Off (EPO) — 08 The battery mode The LCD display in battery mode is shown as The EPO is also referred to as the Remote Power —...
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — 5 LCD settings — 5 1 LCD setting overview You can use the LCD module to access the 5 1 1 Navigating the LCD —...
6 T R O U B L E S H O OT I N G — 6 Troubleshooting If the UPS system is not operating correctly, and fault codes. Use the table below for check the operating status on the LCD display. troubleshooting purposes before contacting Table 12 below provides the problem, possible the After-Sales Service Department.
(around three to five contact your local dealer to order a new battery. years at 25°C ambient temperature). Contact your local ABB or an agent authorized by ABB for information about the replacement. — 7 2 Storage...
8 C O M M U N I C AT I O N P O R T S — 8 Communication ports — 8 1 USB and WinPower communication ports 8 1 1 USB and RS-232 communication ports 8 1 3 Mini AS400 interface (optional) To establish communication between the UPS The UPS is equipped with isolated dry contact...
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — 9 Software — 9 1 WinPower 9 1 1 Free software download—WinPower 9 1 2 Installation — 13 WinPower WinPower is a brand-new UPS monitoring software 1.
1 0 R E A R PA N E L V I E W ( I E C ) — 10 Rear panel view (IEC) — 14 PowerValue 11T G2 1kVA B and PowerValue 11T G2 1kVA S — 15 PowerValue 11T G2 2kVA B and PowerValue 11T G2 2kVA S 12 10...
1 1 T E C H N I C A L S P E C I F I C AT I O N S — 11 Technical specifications — 11 1 Technical Data Sheet GENERAL DATA G2 1kVA B/ S G2 2kVA B/ S G2 3kVA B/ S Output rated power...
P O W E R VA L U E 1 1T G 2 1 - 3 K VA B/ S — 11 2 Battery runtime — Table 13: Battery runtime values UPS+1EBM UPS+2EBM UPS+3EBM UPS+4EBM PowerValue 11T G2 1 kVA B 5/8.5/13.5/27 23/35/65/135 52/80/130/275...
Page 27
1 1 T E C H N I C A L S P E C I F I C AT I O N S...