Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAfETY
ELECTRICAL SAfETY
1.1.
WARNING! It is the user's responsibility to check the following:
‰
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device) is used with all electrical
products. You may obtain an RCd by contacting your local Sealey dealer.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
1.1.1.
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or is
8
replaced immediately by a qualified electrician.
1.1.4.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
GENERAL SAfETY
WARNING! Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and
‰
‰
‰
regulations.
‰ Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
9
‰
WARNING! disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.
‰
‰
‰
‰ Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.
9
‰
‰ Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
‰
‰ only use for pumping liquids under 35°C.
9
‰
‰ If pump is used to pump water from a well, drain or deep receptacle, take adequate precautions to stop persons or animals from
9
‰
falling in.
‰ Use the built-in handle to lower or raise the pump. It may be necessary to attach a suitable rope or pulley to the handle.
9
‰
‰ If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to
9
‰
operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.
‰ In flood situations, user is responsible for ensuring that appropriate back-up procedures, alarms etc are correctly installed in case of
9
‰
pump failure.
‰ In swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond.
9
‰
This pump is not designed for continuous use in a fish pond or similar water feature or display.
8
‰ DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
8
‰
DO NOT use the pump for any purpose other than for that which it is designed.
8
DO NOT use to pump chemicals, fuels or salt water.
8
DO NOT insert hands into the mouth of the pump as this could lead to injury.
8
DO NOT use to pump septic tanks or settling pits. DO NOT pump any liquids other than water.
8
DO NOT operate the pump out of water. The pump pick up area must be completely submerged during operation.
8
DO NOT exceed the maximum submersible depth - see specifications.
8
DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
8
DO NOT use in swimming pools if people could come into contact with the water whilst pump is in use.
8
© Jack Sealey limited
SUBMERSIBLE DIRTY WATER PUMPS -
AUTOMATIC
Model no:
Wear protective
Wear safety
gloves
footwear
Original Language Version
WPD235A.V2, WPS225A.V2
Wear protective
electrical shock
clothing
hazard
WPD235A.V2 WPS225A.V2 Issue 3 (HF) 10/08/18
Recommended fuse rating
WPd235A.V2 5Amp
WPS225A.V2 13 Amp
loading

Summary of Contents for Sealey WPD235A.V2

  • Page 1 WPD235A.V2, WPS225A.V2 Model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Fitted with automatic cut-out. designed for operation in dense and dirty water. Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general transfer of water and dense liquids. 3. SPECIfICATION Model No: ............WPD235A.V2 ..........WPS225A.V2 Cut-out: ..............Automatic ..........Automatic Maximum Head: ..............8mtr ............7.5mtr Maximum Output/Min: ........
  • Page 3 Important: no liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 [email protected]...

This manual is also suitable for:

Wps225a.v2