Only use plugs, adapters, glands, or conduit with a compatible thread form when closing these entries. Contents Wiring diagram for RTDs........ 3 Installation drawings........19 Wiring diagram for thermocouples....4 Declaration of Conformity......20 Product certifications........5 China RoHS..........22 Rosemount 214C...
March 2019 Quick Start Guide Wiring diagram for RTDs Figure 1-1: RTD Lead Wire Configuration per IEC 60751 Single element, 3-wire Single element, 4-wire Dual element, 3-wire Black Black White White Yellow White White Note To configure a single element, 4-wire RTD as a 3-wire system, connect only one white lead.
ASTM E- 230 thermocouple colors Type POS (+) NEG (-) POS (+) NEG (-) Black White White Green White Yellow Brown White Blue Note Dual thermocouple sensors are shipped with one pair of the wires shrink wrapped together. Rosemount 214C...
European Directive information A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification ™...
Page 6
Un-painted aluminum enclosures are Type 4 rated. *Assembly is not Canada Explosionproof (E6) rated to Group B if a 0079 connection head is used. Europe 3.2.1 E1 ATEX Flameproof Certificate DEMKO 16 ATEX 1677X Rosemount 214C...
Page 7
1. Refer to certificate for details regarding process and ambient temperature limits. 2. When the Rosemount 214C sensor is provided with an enclosure with a display cover, the maximum ambient shall be 95 °C. 3. The non-metallic label on the device may store an electrostatic charge and become a source of ignition in Group III atmospheres.
Page 8
3. Unused apertures shall be closed with suitable blanking elements. 4. The enclosures may be provided with up to three ½–14 NPT, ¾–14 NPT, or M20 x 1.5 entries, with location of the entries specified in the installation instructions document. Rosemount 214C...
Page 9
4 J. 5. Flameproof joints are not intended for repair. 6. The stand-alone Rosemount 214C sensors without an enclosure must be assembled to a suitable Ex certified enclosure of a volume no greater than 0.55 L to maintain the types of protection “db” and “tb”.
Page 10
1. Refer to certificate for details regarding process and ambient temperature limits. 2. When the Rosemount 214C sensor is provided with an enclosure with a display cover, the maximum ambient shall be 95 °C. 3. The non-metallic label on the device may store an electrostatic charge and become a source of ignition in Group III atmospheres.
Page 11
1. Refer to certificate for details regarding process and ambient temperature limits. 2. When the Rosemount 214C sensor is provided with an enclosure with a display cover, the maximum ambient shall be 95 °C. 3. The non-metallic label on the device may store an electrostatic charge and become a source of ignition in Group III atmospheres.
Page 12
1. Refer to certificate for details regarding process and ambient temperature limits. 2. When the Rosemount 214C sensor is provided with an enclosure with a display cover, the maximum ambient shall be 95 °C. 3. The non-metallic label on the device may store an electrostatic charge and become a source of ignition in Group III atmospheres.
Page 13
March 2019 Quick Start Guide 3.4.2 I2 Brazil Intrinsic Safety Certificate UL-BR 18.0257X Standards ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-11:2013 Markings Ex ia IIC T6…T5 Ga Thermocouples: P = 500 mW, T6(-60 °C≤T ≤+70 °C) RTDs: P = 192 mW, T6(-60 °C≤T ≤+70 °C) P 290 mW, T6(-60 °C≤T ≤+60 °C), T5(-60 °C≤T...
Page 17
March 2019 Quick Start Guide 分:危险场所电气安装(煤矿除外)”、GB3836.16-2006“爆炸性气 体环境用电气设备 第 16 部分:电气装置的检查和维护(煤矿除 外)”和 GB50257-2014“电气装置安装工程爆炸和火灾危险环境电 力装置施工及验收规范”的有关规定. Korea 3.6.1 EP Korea Flameproof Certificate 17-KA4BO-0305X Markings Ex d IIC T6…T1, T6(-50 °C≤T ≤+80 °C), T5(-50 °C≤T ≤+95° C), T4…T1(-50 °C≤T ≤+100 °C) Special Conditions for Safe Use (X): 1.
Page 18
Combination of E5 and E6 Combination of E1 and E5 Combination of E1, E5, and E6 Combination of E1, E5, E6, and E7 Combination of EM and IM Combination of N1, N5, N6, and N7s Combination of EP and IP Rosemount 214C...
O: Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of GB/T 26572. GB/T 26572 X: Indicate that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. Rosemount 214C...
Page 23
March 2019 Quick Start Guide Quick Start Guide...
Page 24
The Emerson logo is a Facebook.com/Rosemount trademark and service mark of Emerson Electric Youtube.com/user/ Co. Rosemount is mark of one of the Emerson RosemountMeasurement family of companies. All other marks are the Google.com/+RosemountMeasurement property of their respective owners.