ABB DCS880 Series Quick Manual

ABB DCS880 Series Quick Manual

Industrial drives
Hide thumbs Also See for DCS880 Series:
D C D r i v e s
ABB industrial drives
DCS880 Quick guide
Table of Contents
loading

Summary of Contents for ABB DCS880 Series

  • Page 1 — D C D r i v e s ABB industrial drives DCS880 Quick guide...
  • Page 2: Table Of Contents

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 —...
  • Page 3 ABB has created Dienstleistung anbieten zu ai nostri clienti lo stesso servizio clientes en todo el mundo, ABB ha the DRIVE SERVICE CONCEPT. können, hat ABB das DRIVE post vendita in tutto il mondo.
  • Page 4: Eu Safety Instruction

    *481R0101A6460000* brændbare. - Conecte a tierra el convertidor. Conecte a tierra el terminal de © 2016 ABB. All rights reserved.3ADW000481R0101 Rev. A 11-2016 - Løft omformeren op med en løfteanordning. Brug løfteøjer/-beslag protección a tierra (PE) del convertidor. Tá sa cháipéis seo treoracha sábháilteachta. Cloígh leis na treoracha.
  • Page 5 D C D r i v e s golfari/le barre di sollevamento. - Asiguraţi-vă că podeaua de dedesubtul convertorului şi peretele din - Med delovanjem in po vklopu napetosti morajo biti pokrovi/vrata zaprti. Nederlands / Veiligheidsvoorschriften - Non inclinare il convertitore. Può ribaltarsi facilmente. spatele său nu sunt inflamabile.
  • Page 6: Dcs880 Drive Manuals

    All information are available on the Internet by following links: • DCS880 documentation www.abb.com " Search for DCS880 Direct link: DCS880 CD download • ABB Drive composer entry PC tool for parameterization, commissioning and service www.abb.com " Search for drive composer Direct link: ABB Drive composer...
  • Page 7 D C D r i v e s DCS880 DC drive Thyristor Power controller DCT880 With the new DCT880 ABB offers its customers a thyristor Our DCS880 industrial drives are customized to meet the power controllers for precise control of resistive or...
  • Page 8: Ratings, Types And Voltages

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 9: Unpacking And Mechanical Installation

    D C D r i v e s D C D r i v e s — Unpacking and mechanical installation Unpacking and examining the delivery Size H1 … H3 Size H4 Size H5 Do not lift the drive by the cover! BG_DCS_001_verpackung_a.ai Mechanical installation Before installation...
  • Page 10: Type Code And Plus Codes

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 11: Brief Instructions For Virtual Cd And Documents Overview

    D C D r i v e s — Brief instructions for virtual CD and documents overview System requirements to use the virtual We appreciate that you purchased an ABB DC drive power converter and thank you for the trust you put in our DCS880 CD products.
  • Page 12: Notes On Emc

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 13 Standard EN 61800-3. Converter Converter transformer transformer iron core Earthed For the DCS880 series, the iron core Earthed (and earthed neutral (and earthed I > 400 A neutral Earthed 400 V network limit values for emitted I >...
  • Page 14: Start, Stop And E-Stop Control

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 15: Planning The Electrical Installation, Size H1 5

    D C D r i v e s D C D r i v e s — Planning the electrical installation, size H1 ... H5 Converters size H1 ... H5 configuration using an OnBoard field exciter Wiring the drive according to this diagram offers the highest degree of monitoring functions done by the drive. Attention: DIOGND IACT...
  • Page 16: Terminal Locations Of The Converter

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 17: Control Circuit Terminal Layout

    D C D r i v e s D C D r i v e s — Control circuit terminal layout DCS880 Recommended wire size - Tightening torques Reference voltage and analog inputs Control cables: +VREF +10 V -VREF -10 V Wire sizes: Tightening torques: AGND...
  • Page 18: Notes For North American Installations

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 19 • Wire analog inputs (e.g., speed reference) and outputs (e.g., meters for motor voltage, current) to terminal block XAI. Check converter for damage. Contact ABB Technical Support if damage is found. In North America, call • Wire high speed serial interface if needed. (Requires 1-800-435-7365 (1-800-HELP-365) optional fieldbus interface board.)
  • Page 20: Dcs880 Control Panel

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 21: Drive Composer Pc Tool

    • DCS880 commissioning assistants The tool can be downloaded free of • Compare parameter files and parameter sets charge from ABB internet home page. • Fast monitoring of signals Drive composer entry include • One or more drive can be connected via Control panel USB...
  • Page 22: Parameter Groups

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 23: Safety Instructions, Drives Commisioning

    D C D r i v e s D C D r i v e s — Safety instructions, drives commisioning Dangerous voltage warning warns of high voltage • Ensure sufficient cooling. which can cause physical injury and/or damage to •...
  • Page 24: Autotuning Warning Af90

    Tuning of speed controller, speed feedback assistant or 0001000B Unable to detect a field inductance. 0001000C Firmware fault. Contact your local ABB representative. tacho fine-tuning not possible due to voltage limitation. During the tuning of the speed controller, the speed 00020002 •...
  • Page 25: Environmental Conditions

    D C D r i v e s D C D r i v e s — Environmental conditions System connections Environmental limit values Voltage, 3-phase: 100 ... ≤ 1000 V acc. to IEC 60038 Permissible cooling air temp. Voltage deviation: ±10 % continuous;...
  • Page 26: User Macros

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e — User macros ABB Standard Aux.supply 525V 50/60 Hz L1.1 N...
  • Page 27 D C D r i v e s D C D r i v e s ABB Standard US Aux.supply 525V 50/60 Hz L1.1 N (2-wire DC contact) XSMC:1 Sample circuit E-STOP Cat 0 with DCS880 STO XSMC:2 XSMC:3 Safety...
  • Page 28 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e Standard 3-wire Aux.supply...
  • Page 29 D C D r i v e s D C D r i v e s Standard 3-wire US Aux.supply 525V 50/60 Hz L1.1 N (3-wire DC contact) XSMC:1 Sample circuit E-STOP Cat 0 with DCS880 STO XSMC:2 XSMC:3 Safety OFF2 Relais XSMC:4...
  • Page 30 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e Local I/O / Fieldbus Aux.supply...
  • Page 31 D C D r i v e s D C D r i v e s Motor potentiometer Aux.supply 525V 50/60 Hz L1.1 N XSMC:1 Sample circuit E-STOP Cat 0 with DCS880 STO XSMC:2 XSMC:3 Safety OFF2 Relais XSMC:4 Line reactor Reset XRO1 12 11...
  • Page 32 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e Speed / Torque Aux.supply...
  • Page 33: Drive Logic And Main Control Word

    D C D r i v e s D C D r i v e s — Drive logic and main control word...
  • Page 34: Fieldbus Control

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 35: Overview Control (Drive Composer Printout)

    D C D r i v e s D C D r i v e s — Overview control (Drive composer printout)
  • Page 36: Declarations

    A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e - 3 A D W 0 0 0 4 8 0 R 0 2 0 1 A B B i n d u s t r i A l d r i v e s D C S 8 8 0 Q u i C k g u i D e —...
  • Page 37 D C D r i v e s D C D r i v e s...
  • Page 38: Dcs Family

    Thyristor controller • Two or three phase devices • Power optimizer for peak load reduction … 4,200 A • Built on ABB‘s all-compatible drives architecture … 990 V • Intuitive control panel and PC tool with USB connection and IP00 start up assistant •...
  • Page 39 D C D r i v e s D C D r i v e s...
  • Page 40 — www.abb.com/dc-drives www.abb.com/drivespartners © Copyright 2019 ABB. All rights reserved. Specifications subject to change without notice.

Table of Contents