NOTICE!
You must upgrade G Series and Non-G Series control panels to GV2 programming prior to
upgrading to GV3 programming.
2.3.1
Upgrade a GV2 Series, G Series, or Non-G Series Control Panel to a GV3
v8.03 or Later Using Remote Programming Software (RPS) 5.13 or Later
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Test the control panel for operation.
Bosch Security Systems, Inc.
In RPS, highlight the control panel name by selecting it.
Click the View button on the Remote Programmer Toolbar.
In the resulting Panel Data - View window, click the Edit button.
In the resulting Panel Data - Edit window, select the new control panel type from the
Panel Type drop-down. (If the control panel is a G or Non-G Series control panel, you
must upgrade to GV2 first, and then repeat each of these steps to choose the GV3
control panel.) Click OK to close the window.
Click Save in the Panel View window to save the changes and close the Panel View
window.
Click Connect. Once connected, the Panel Sync window opens.
Select the Send ALL RPS Data to Panel option button and click OK.
Once the sync completes, click Disconnect to disconnect from the control panel.
Exit RPS.
Quick Reference Guide
Upgrade GV3 Hardware and Programming | en