Siemens SIMATIC HMI IPC677C Operating Instructions Manual

Siemens SIMATIC HMI IPC677C Operating Instructions Manual

Hide thumbs Also See for SIMATIC HMI IPC677C:
Table of Contents
SIMATIC HMI IPC677C
SIMATIC HMI
Industrial PC
SIMATIC HMI IPC677C
Operating Instructions
04/2013
A5E02722710-04
___________________
Preface
___________________
Safety
___________________
Description
___________________
Planning the use
___________________
Mounting
___________________
Connecting
___________________
Integration into an
automation system
___________________
Commissioning
___________________
Operation and configuration
___________________
Operation
___________________
Functions
___________________
Service and maintenance
___________________
Alarm, error, and system
messages
___________________
Troubleshooting/FAQs
___________________
Technical data
___________________
Dimensional drawings
___________________
Detailed descriptions
___________________
Appendix
___________________
List of abbreviations
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
Table of Contents
loading

Summary of Contents for Siemens SIMATIC HMI IPC677C

  • Page 1 ___________________ SIMATIC HMI IPC677C Preface ___________________ Safety ___________________ Description ___________________ Planning the use SIMATIC HMI ___________________ Mounting ___________________ Industrial PC Connecting SIMATIC HMI IPC677C ___________________ Integration into an automation system ___________________ Commissioning Operating Instructions ___________________ Operation and configuration ___________________ Operation...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Please refer to sections "Application planning" and "Technical data". Position in the information landscape The documentation for the Panel PC includes the following sections: ● SIMATIC HMI IPC677C, Operating Instructions (compact), with the following information: – Commissioning – Legal information ●...
  • Page 4 Trademarks All names labeled with ® symbol are registered trademarks of Siemens AG. Other names used in this documentation may be trademarks, the use of which by third parties for their own purposes could violate the rights of the owner.
  • Page 5: Table Of Contents

    Connecting the 100 - 240 V AC Power Supply................46 Connecting the (24 V) DC power supply ..................49 Connecting the Equipotential Bonding Circuit ................50 Equipotential bonding with stainless steel front ................51 Connecting Ethernet/USB strain relief ..................51 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 6 Deactivate touch functionality ..................... 85 8.3.5 KeyTools (for key panel devices)....................86 8.3.6 On-screen keyboard (for touch panel device)................86 8.3.7 Panel PC Tools for Windows XP and Windows Embedded Standard 2009 ......87 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 7 Separating the control unit from the computer unit..............119 11.7 Expansion and parameter assignment ..................121 11.7.1 Opening the Device ........................121 11.7.2 Memory expansion........................123 11.7.2.1 Removing/Installing Memory Module..................123 11.7.3 Installing PCI/PCIe cards ......................125 11.7.3.1 Notes on the modules ........................125 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 8 BIOS update..........................161 11.12 BIOS Recovery ......................... 162 Alarm, error, and system messages ...................... 163 12.1 Boot error messages......................... 163 12.2 Introduction to the BIOS beep codes ..................164 12.3 BIOS beep codes ........................164 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 9 16.3.2.6 Accessing addresses of LEDs, watchdog and battery status............221 16.4 BIOS-Setup ..........................221 16.4.1 Overview ............................221 16.4.2 Starting BIOS Setup........................222 16.4.3 BIOS Setup menus ........................223 16.4.4 Main menu ..........................225 16.4.5 Advanced menu .........................226 16.4.6 "Advanced, Active Management Technology Support" menu ...........233 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 10 Further actions in STEP 7/NCM PC..................258 Appendix..............................259 Guidelines and declarations...................... 259 Standards, certificates and approvals..................260 Service and support ........................264 List of abbreviations..........................265 Abbreviations ..........................265 Glossary ..............................271 Index..............................277 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 11: Safety

    Electrical connection WARNING Disconnect the device from the mains before every intervention. Do not touch power lines or data transmission lines during electrical storms and do not connect any cables. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 12 Only authorized personnel are permitted to repair the device. WARNING Unauthorized opening of and improper repairs to the device may result in substantial damage to equipment or risk of personal injury to the user. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 13: General Information

    Optical drives are sensitive to vibration. Inadmissible vibration during operation may result in loss of data or damage to the drive or data medium. Before transporting the device, wait at least 20 seconds to allow the drive to stop completely. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 14 Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. Downloads are available on the Internet at "Support". http://www.siemens.com/asis (https://www.automation.siemens.com/Industrial-PC/html_76/support/asis.htm).Under "ASIS", click on "Drivers and Bios Updates" and select the device family. Alternatively, click on "Downloads"...
  • Page 15 ● Screen savers that switch off the backlighting shorten the life span of the backlighting. Consider the following carefully: ● Screen saver ● Switch off the backlighting regularly ● Permanent display of the customer application SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 16: Esd Directives

    When working with electrostatically sensitive components, make sure that the person, the workstation and the packaging are properly grounded. Conduct the electrostatic charge away from your body by touching the mounting plate for the interfaces, for example. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 17 ESD component in plastic bags or plastic film. In ESD components containing installed batteries, make sure that the conductive packaging does not touch the battery connectors or short circuit. Insulate the connectors with suitable material. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 18 Safety 1.3 ESD directives SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 19: Description

    Computer unit Control unit Figure 2-1 IPC677C Product Brief The device is available with different control units which are distinguished by the size of the display and by the key or touch panel. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 20 ● LEDs for power supply and temperature ● Front-mounted USB 2.0 port for connecting external I/O devices (except INOX). All fronts are also available without USB port accessible from the front. Refer to the "Specifications" section for more information. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 21: Features

    1 x 3.5" hard disk or • 2 x 2.5" hard disk or RAID1 system • Capacity see order forms DVD drive DVD burner Flash memory Slot for Compact Flash card • 1 x solid-state drive • SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 22 1) 2) The DMAPI programming interface is available to activate the LEDs and the SRAM . You will find this in the folder "C:\Program Files\Siemens\DiagnosticManagement\DMAPI". only with devices with PROFIBUS or PROFINET interface SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 23 Preinstalled / activated / available on the Restore • CD/DVD: – Windows Embedded Standard 2009 English on CompactFlash – Windows XP Professional MUI – Windows 7 Ultimate MUI 32/64-bit MUI: Multilanguage User Interface; 6 languages (English, German, French, Spanish, Italian) SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 24: Accessories Of Ipc677C

    Module for DDR3 RAM, DIMM expansion 1 GB 6ES7648-2AH40-0KA0 2 GB 6ES7648-2AH50-0KA0 1 GB, ECC 6ES7648-2AH40-1KA0 2 GB, ECC 6ES7648-2AH50-1KA0 You can find additional accessories in the catalog or on the Internet at http://www.siemens.com/automation/mall (http://mall.automation.siemens.com). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 25: Planning The Use

    ● Swivel arm mounting ● Rack mounting Note In the following, the term "switchgear cabinet" also refers to rack, mounting rack, switchboard, operator panel and console. The term "device" represents the Panel PC and its variants. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 26: Unpacking And Checking The Delivery

    "SIMATIC IPC/PG quality control report". WARNING Make sure that a damaged device is not installed nor put into operation. 8. Note the identification information as described in the chapter "Identification data of the device". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 27: Device Identification Data

    The Product Key is always required to reinstall the operating system. COA label Serial number: S VP ... Order No. 6AV78..Microsoft Windows Product Key Ethernet address 1 Ethernet address 2 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 28: Mounting Positions And Fastening

    The ensuing forces could lead to possible irreversible damage of the hard disk. ● The device has to be installed in the mounting cutout of a housing that fulfills the requirements of IEC/EN/DIN EN 60950-1, Chapters 4.6 and 4.7.3. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 29 UL-approval and compliance with the low-voltage directive (via EN 60950-1). In additional, the functionality of the device is no longer guaranteed. Additional information is available in the chapter "Dimensional drawings (Page 191)". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 30: Installation Information Stainless Steel Front

    Permissible deviations from the vertical mounting position Temperature Angle A Angle B 12"; 15" up to 50 °C 20° 20° 19" up to 45 °C 20° 20° With a total loading of slots amounting to 15 W SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 31: Type Of Fixation

    Degree of protection NOTICE Degree of protection IP66 is only ensured if the seal of the device is correctly positioned and evenly pressed on the control panel. Refer to the "Installation" section for more information. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 32: Protection Against Dust And Water

    IP54 degree of protection The IP54 degree of protection is applicable for the following conditions: Key panel Touch panel 12" 15" 15" 19" Screw mounting See also Industry Mall (http://mall.automation.siemens.com) SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 33: Mounting Cutout

    Drill holes for the screws and pressure points for the clamp screws Note Mounting dimensions can be read from the dimension overview or they can be transferred to the cabinet from the mounting template supplied. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 34 On the basis of the dimensions, check whether the required screw and pressure points on the rear and the seal area are easily accessible after the completion of the mounting cut-out. Otherwise the mounting cut-out is useless. Complete the mounting cut-out in accordance with the dimensions. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 35: Mounting Depth Of The Device

    Touch panel with 15" TFT INOX 126 mm Touch panel with 19" TFT 130 mm Note Additional mounting depth with optical drive The installation depth increases by 21 mm when an optical drive is installed in the device. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 36 Planning the use 3.5 Mounting cutout SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 37: Mounting

    The degrees of protection are only guaranteed when the following is observed: • The surface plane deviation of the mounting cut-out in relation to the external dimensions of the control unit amounts to ≤ 0.5 mm when the control unit is mounted. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 38: Securing With Screws

    2. Working from the front, insert the device into the 19" rack on the swivel arm or in the mounting cut-out of the control cabinet. 3. Secure the control unit by inserting suitable screws and nuts. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 39: Fix The Device With Stainless Steel Front Using Clamps

    2. Working from the front, insert the device into the prepared and deburred mounting cut- out. Take the necessary precautions to ensure the device cannot drop out of the control panel before it has been secured in place. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 40 0.6 N/m in order to achieve an optimal sealing effect. NOTICE Any higher torque may warp the control panel or the switchboard panel. The specified degree of protection is not ensured otherwise. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 41 Figure 4-4 Proper positioning of the clamp Figure 4-5 Position of the clamps 6. Check the proper seating of the seal on the front side. If it is not seated properly, repeat the installation. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 42 Mounting 4.3 Fix the device with stainless steel front using clamps SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 43: Connecting

    (only 2 ports can be simultaneously used as high current) ⑤ ETHERNET 2x RJ 45 Ethernet connection for 10/100/1000 Mbps ⑥ PROFIBUS/MPI MPI port (RS485, electrically isolated), optional 9-pin D-sub socket (optional product model) SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 44 Access to 2nd LVDS display port for TFT displays up to 1280 x 1024 ③ USB 2.0 for front ④ Retaining screw for the steel cover plate that covers the ports described below. ⑤ I/O port for connecting front components SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 45 100 V AC to 240 V AC. DC power supply Position of the DC power connector Description Plug connector for DC power supply of the device ① + (24 V DC) - (ground) ② PE (ground terminal) ③ SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 46: Connecting The 100 - 240 V Ac Power Supply

    A master mains disconnect switch must be installed if the device is mounted in a switch cabinet. Make sure that the power outlet or the safety power outlet of the building installation is freely accessible and located as close as possible to the device. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 47 A flexible cable with UL approval and with CSA label which has the following features is to be used: Type SJT with three conductors, min. 18 AWG conductor cross-section, max. length 4.5 m, and tandem grounded connector 15 A, min. 250 V. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 48 Connect the IEC connector Connecting the power cord to the power socket Fasten the cable with the supplied power plug ① latch , if necessary. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 49: Connecting The (24 V) Dc Power Supply

    24 V power supply. Switch off the 24 V DC power source. Insert the DC power plug. ① DC 24 V ② ground ③ protective conductor SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 50: Connecting The Equipotential Bonding Circuit

    I/O modules are safely discharged to ground. The equipotential bonding connection of the device is located underneath the device and is identified by the following symbol: Figure 5-1 Equipotential Bonding SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 51: Equipotential Bonding With Stainless Steel Front

    Steps for connecting the Ethernet/USB strain relief ① Fasten the Ethernet/USB strain relief to the device enclosure with two oval-head screws (M3 thread). Connect the network/USB cable and attach it to the ② strain relief using cable ties SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 52: Connecting The Profinet Strain Relief

    You require a TORX T20 screwdriver for attaching it to the housing. The power plug locking mechanism is a safety-relevant part. Read the information in the chapter "Connecting the (120 V / 240 V AC) power supply". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 53: Integration Into An Automation System

    PROFINET interface will act like a 100 Mbit Ethernet interface with a MAC address when you use this driver. The three RJ45 sockets are connected with each other via a switch. The driver and the documentation can be found in the supplied Documentation and Drivers SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 54: Device In Simatic S7 Network

    Information on this can be found on the SIMATIC NET Manual Collection CD. The software package and the documentation are not included in the package. Additional information You can find additional information in the catalog and in the Internet of Siemens A&D. http://www.siemens.com/automation/mall Device in SIMATIC S7 network 6.2.1...
  • Page 55: Connecting An S7 Automation System

    2. Insert the PROFIBUS cable in the MPI/DP socket. 3. Reconnect the device to the electrical power system. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 56: Transferring Authorizations

    You can establish a network between the device and other computers via Industrial Ethernet. The on-board LAN interface is a twisted-pair (TP) interface for data transfer rates of 10/100/1000 Mbps. Note A catagory 6 Ethernet cable is required for 1000 Mbps operation. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 57: Profinet

    NOTICE Only one CP 1616 can be installed in a PC. If you want to use an additional CP 1616 module, the "CP 1616 onboard" option must be disabled in the BIOS Setup. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 58 Read this guide if you want to install the NDIS device Device Driver CP16xx.sys driver, CP16xx.sys. Further information You can find the information on specific products in the Internet at the address: http://www.siemens.com/simatic-net SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 59: Commissioning

    ● The operating system you ordered for your device is already installed on the hard disk. Switching on the device Note Commission the device before you install additional hardware, such as a PCI interface card. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 60: Windows Xp, Windows 7 Security Center

    You will also receive a warning if programs attempt to modify important Windows settings. Configure the Security Center according to your requirements. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 61: Setting Up The Microsoft Windows Operating System

    ● The "SIMATIC PC Wizard" program is automatically started once during the first commissioning. ● The wizard will automatically set the device-specific drivers and applications at the initial start of the operating system. ● The hardware is detected automatically. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 62 Do not switch off the device during the software installation. Follow the instructions that appear on the screen right to the end of installation. The dialogs can differ for different Windows operating systems. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 63: Touch Panel Set-Up

    The configuration of the HMI device will be detected and set automatically. During the hardware recognition, the Touch Controller is detected again and entered. 1. Calibrate the touch screen by touching the selected points as shown in the illustration. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 64 In Windows 7 the Windows on-screen keyboard will not appear until you have assigned a password for the user account. 3. Use the "Finish" button to terminate the wizard. The HMI device will be automatically restarted for the respective configuration. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 65: Key Panel Adjustment

    ● The "SIMATIC IPC Wizard" program is automatically started once during the first commissioning. ● The wizard will automatically set the device-specific drivers and applications at the initial start of the operating system. ● The hardware is detected automatically. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 66 The dialogs can differ for different Windows operating systems. The PC will restart after installation is complete. Additional information about the IPC wizard software can be found in the "SIMATIC IPC Wizard" operating manual on the included "Documentation and Drivers" DVD. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 67: Bios Settings

    When installing a USB device for the first time, make sure you have the required device driver. Before removing an intelligent USB device, deactivate the device in the operating system using the dialog "Unplug or Eject Hardware". For additional information, refer to the documentation for the operating system. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 68: Notes On Operation

    To be on the safe side, data should be verified after every burning session. When backing up an image, the data should be restored to the hard disk and the system should be rebooted from the hard disk. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 69: 2Hdd System (Optional)

    "+" key to move it up in the boot order. Note The drive letters for the partitions on both drives are assigned by the operating system used. You can change these in the Control Panel as required. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 70: Raid1 System (Optional)

    Partition D: Data, NTFS, remaining capacity Note You can find information regarding Intel RAID controllers in the RAID documentation on the included "Documentation and Drivers" CD in the Drivers\RAID\Intel directory. Figure 7-1 Example SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 71 The redundant system state RAID 1 is reached again only after synchronization is completed. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 72: Replacing A Defective Drive In The Raid System

    Degraded message of RAID software Replace defective RAID drives with a new drive in order to recover secure RAID1 state. The RAID software reports the defective drive and returns details of the operable hard drive. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 73 Note The new HDD can be integrated into the RAID system at operating system level by means of the RAID software. Synchronization may take several hours, depending on system load. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 74 The "SIMATIC PC DiagMonitor" diagnostics and alarm software also provides information about the RAID status. This software only needs to be installed once - logons are not required. The diagnostics and alarm software "SIMATIC DiagMonitor " is available as an accessory. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 75: Compact Flash Card (Optional)

    7.9.5 Compact Flash card (optional) Note We highly recommend that use use approved SIMATIC Compact Flash cards. Siemens disclaims any liability for impairment of functions caused by the use of third-party cards. Design A Compact Flash card can be used on-board and in an extra mount. This mount replaces the usual hard disk mount.
  • Page 76 A operating system must be installed before you can boot from the Flash drive. You can read about the procedure required for installation of an operating system in the section Installing Windows (Page 150). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 77: Operation And Configuration

    (Off), the device is still supplied with mains voltage in order to generated the internal auxiliary voltage for the power supply. Note Terminate the operating system before shutting down the device with the on/off switch, otherwise data may be lost. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 78 By default, the BIOS Setup entry "After Power Failure" is set to "Power On". This means the device is switched on with the on/off switch and you do not have to operate the on/off button. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 79: Normal Operation

    "Operation and configuration" chapter in the section, "Additional drivers and applications." ● The proper ambient and environmental conditions according to the specifications for the device and the connected I/O modules have been observed. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 80: Logging On To The Operating System Using The On-Screen Keyboard

    An on-screen keyboard (OSK) appears for devices with touch screen panels. You can enter the administrator password directly on the touch screen using the screen keyboard or using the mouse. For additional information, refer to the Microsoft help on screen keyboards. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 81: Switching Off The Device

    The supplied drivers and applications have been system-tested and are approved for this device. No warranty can be provided for other software. Press the "Help" button to obtain information concerning the buttons of a dialog. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 82: Standard Calibration Procedure

    The entry is confirmed by a check mark, the next selection is displayed. 7. Confirm all input prompts (arrows, or crosses in the center) until the complete screen has been calibrated. 8. Finally, confirm the input prompt "Confirm". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 83: Activate Touch Functionality

    The "UPDD Console" dialog box opens. Figure 8-2 Activate touch functionality ① 2. Select the corresponding Controller ③ ② 3. Set a tick in the "Enabled" option box in the "Properties" tab. The Controller is activated. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 84: Extended Touch Touch Functionality

    Extended touch applies only to the Windows 7 Ultimate operating system. If "Extended touch" is selected, the extended touch functions of Windows 7 will be available, such as operating touch permanently, which corresponds to the right mouse button function. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 85: Deactivate Touch Functionality

    Restart the "UPDD Console" via the start menu. ③ The keyboard entry opens the tab "Properties" . Then the Touch Panel can be ② reactivated by entering . (option box "Enabled" SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 86: Keytools (For Key Panel Devices)

    Calling up KeyTools 1. Select "Start > Settings > Control Panel > SIMATIC KeyTools". For Windows 7: Select "Start > Programs > Siemens Automation > SIMATIC > IPC Wizard > IPC KeyTools > IPC KeyTools". 2. Select the desired application and follow the instructions on the screen.
  • Page 87: Panel Pc Tools For Windows Xp And Windows Embedded Standard 2009

    You can use the "<" and ">" buttons to change the value in each case in increments of one, the "<<" and ">>" buttons to change the value in increments of ten. The "MIN" button set the brightness to the value 0, "MAX" to the value 100. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 88: Panel Pc Tools For Windows 7

    Batch jobs Alternatively, you can control the brightness using a software program. To do this, call the following Windows batch job in the folder "C:\Program Files\Siemens\PPC Tools": "BrightnessControl" You use the command-line parameters to switch the backlighting on and off, set the brightness to a specific value, or change the brightness at each call in specific increments.
  • Page 89 If the "SetBrightness" program is started with the parameter "-experthelp", an extended help text is displayed. The "SetBrightness" program can be called in the command line with the following options: SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 90 Notice: The respective numbers of the operable displays are shifted accordingly. Example: SetBrightness.exe –set 75 –device 2 Sets the brightness of display "2" to 75%. Only the –plugin FPPlugin.dll "FPPlugin.dll" plugin is loaded. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 91 A connection to the specified display could not be established. 0x8000000B The current brightness value could not be determined. 0x8000000C The brightness value could not be controlled. 0x8000000D The "SetBrightness" program is already running. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 92: Bbcscreensaver

    During the start of Windows, the additional device is recognized by the service of the screensaver and integrated. Procedure 1. Open the "Screen Saver Settings" dialog with "Start > Settings > Control Panel > Display". 2. Select the "BbcScreenSaver" under "Screen Saver". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 93 6. Confirm the set values with "OK" or terminate the input with "Cancel" without saving the modified settings. Note If you set the value 0, the backlighting of all connected monitors is turned off. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 94: Checklanguageid

    The following description applies for 32-bit Windows operating systems. Call "c:\drivers\checklang\checklangid.exe" or reinstallation from the "Documentation and Drivers" CD. For Windows 7: Select Start > Programs > Siemens Automation > SIMATIC > IPC Wizard > CheckLangID Function "CheckLanguageID" displays the currently installed languages.
  • Page 95: Multilingual Settings For The Operating System

    ● Adjustment of the backlighting brightness with the application "SetBrightness." ● Control of the key LEDs You can find details about the installation on the "Documentation and Drivers" CD. Note on Windows 7: Installation is carried out via the IPC Wizard. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 96 Operation and configuration 8.3 Additional drivers and applications SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 97: Operation

    The two "virtual" CP 1616 LEDs can only be seen in the SIMATIC software and can be scanned via SNMP. PROFINET Virtual LEDs CP is active STOP CP is in the stop state Flashes There are no "slow flashing" or "fast flashing" states. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 98: Device With Key Panel

    F13 to S16 are used or if own key code tables are used. Risk of damage Activating a key using a hard or pointed object, for example a screwdriver, reduces the life of the key or can damage it. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 99: Overview

    Display Alphanumeric keys Numeric keys Control keys Cursor keys Integrated mouse Function keys Softkeys USB ports (optional) Figure 9-1 Example of a 12" key panel SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 100: Keys

    Application-specific function key codes (see key code table in appendix) Application-specific function key codes (see key code table in appendix) Toggling between lower-case letters and upper-case letters Function key (10) Call Help (11) Tabulator (12) Backspace Figure 9-2 Control keys SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 101: Alphanumeric And Numeric Keys

    The LED on the key is then also lit. Numeric keys Enter the numerals "0" to "9" and special characters, e.g. the decimal point, using the pre- defined assignment of the numeric keys. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 102: Cursor Keys

    Navigate, scroll or move the writing mark using the cursor keys. The cursor keys correspond to the usual keys of the PC keyboard. key key key key Position 1 key (Home) key key Figure 9-4 Cursor keys SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 103: External Keyboards

    The device is supplied with a sheet of labeling strips. CAUTION Labeling Label the function keys and softkeys to conform with the project. Labeling without reference to a project leads to incorrect operations on the system to be observed. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 104 Rear of the control unit, using example of a 12" key panel. Similar to illustration, can deviate from device Slots for long labeling strips, vertical keypads Slots for short labeling strips, horizontal keypads Slots for labeling strips, horizontal keypads SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 105: Using The Integrated Mouse

    The following types of pressure are permissible: ● Using a touch pen with a 1 mm radius at the point: 25 g. ● Using a silicone finger with a diameter of 1.6 cm: 50 g. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 106 A touch pen is available as an accessory. Figure 9-8 Touch pen Dimensions Length 155 mm Maximum diameter 20 mm NOTICE Damage to the keys The touch pen is not appropriate for operating the keys. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 107: Functions

    AMT is a technology from Intel for remote maintenance of computers. You turn an AMT PC on and off remotely and start the BIOS setup remotely. Different operating systems can be booted with ISO files. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 108: Temperature Monitoring

    The watchdog monitors IPC execution and reports a crash of the IPC to the user by means of various reactions. The watchdog is idle when the PC is switched on or after a HW-RESET(cold restart), i.e., no reaction of the WD is triggered. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 109: Fan Monitoring

    The fan fault is retained in memory until the cause of the fan failure has been rectified and the error is reset by taking one of the following measures: ● Acknowledgment of the error message by the monitoring software ● Restart of the device SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 110: Status Display

    A maximum 2 MB memory window is displayed via a PCI address register. The base address is initialized by the BIOS. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 111: Battery Monitoring

    An ISO file contains a memory image of the content of a CD or DVD structured in the ISO 9660 format. ● Remote reboot: An AMT PC can be booted from a bootable ISO file made available by another PC. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 112 SIMATIC IPC Remote Manager The "SIMATIC IPC Remote Manager" software is available for utilization of the AMT functions with SIMATIC IPCs. The software can be ordered from the Siemens online ordering system. For detailed information about "SIMATIC IPC Remote Manager", refer to the corresponding product documentation.
  • Page 113: Service And Maintenance

    The rear side of the operator unit and the housing of the computer unit must only be dry- cleaned. NOTICE Do not clean the device with aggressive solvents or scrubbing agents or with pressurized air or steam cleaner. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 114: Maintenance And Care Of Devices With Stainless Steel Front

    Observe the permitted ambient temperatures. For additional information, refer to the chapters: ● Planning the use (Page 25), section "Mounting positions and fastening (Page 28)" ● Technical data (Page 175), section "General specifications (Page 175)" SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 115 7. Remove the moisture with the window wiper, working from top to bottom and without leaving any streaks. After each pass, wipe off the window wiper with soft household paper. Wipe off any water accumulating on the bottom edge of the front membrane using soft household paper. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 116: Chemical Resistance Of Stainless Steel Fronts

    ● Clean the stainless steel surface with a neutral, alkaline cleaner or, if necessary, with a caustic cleaner which does not contain active chlorine. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 117 – Remove any stains or extraneous rust immediately. – Remove new rust spots with a mild abrasive detergent in order to prevent any further corrosion. – Rinse the part thoroughly after you cleaned it. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 118: Spare Parts

    Service and maintenance 11.5 Spare parts 11.5 Spare parts Use only Siemens spare parts or spare parts released by Siemens, otherwise the warranty, CE declaration of conformity and UL approval will be invalidated. Fronts Front type Description Front USB Order number 12"...
  • Page 119: Separating The Control Unit From The Computer Unit

    6. Two mounting rails are screwed onto the computer unit whose angled clips (4) are located in the corresponding recesses in the computer unit. Lift the computer unit vertically out of these recesses SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 120 So that the processing unit, which is swung away from the control unit, does not bend the lugs (4), place a surface under the processing unit. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 121: Expansion And Parameter Assignment

    The device contains electronic components which may be destroyed by electrostatic charge. You therefore need to take precautionary measures before you open the device. Refer to the ESD guidelines on handling electrostatically sensitive components (Page 260). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 122 All technical data and approvals apply only to expansion units which are released by SIEMENS. Siemens disclaims any liability for impairment of functions caused by the use of third-party devices or components. Observe the installation instructions for the components. UL approval of the device only applies when the UL-approved components are used according to their "Conditions of...
  • Page 123: Memory Expansion

    Always take appropriate precautionary measures when handling these components. Refer to the ESD directives on handling electrostatic sensitive components. Note We highly recommend using memory modules approved by Siemens. Siemens disclaims any liability for impairment of functions caused by the use of third-party memory modules. SIMATIC HMI IPC677C...
  • Page 124 Display of the current memory configuration A new memory module is automatically detected. When switching on the device and starting the BIOS Setup using , the current memory size is displayed under "Total Memory". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 125: Installing Pci/Pcie Cards

    ⑥ Observe the guide rail with long PCI modules. Mount the module bracket and ③ insert the slider ① Fasten the slot cover of the expansion module. Close the device. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 126 The two slots for the PCI cards each have an exclusive interrupt. Information on the assignment of the PCI IRQ line to the PCI slot is available in the BIOS setup, "Advanced menu" section, and in the detailed descriptions of the "Bus board" section. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 127: Installing Drives

    Slot for one 3.5" drive ② Hard disk drive bay for one 3.5" drive Two 2.5" hard disks Item Description ① Two slots for 2.5" hard disks ② Hard disk drive bay for 2.5" hard disks SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 128: Installing/Removing A Drive Bay Module

    Removing a drive bay module for hard disks and optical drives Steps for removing the drive bay ① Remove the four screws Lift out the drive bay module for hard disks and the optical drive. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 129: Removing / Installing An Optical Drive

    Remove the drive bay module. ① Loosen the screws on the DVD burner drive bay. ① Remove the retaining screws the drive. Disconnect the power supply and the data cable from the drive. Lift the drive out. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 130: Installing / Removing Hard Disks

    Disconnect the power supply and the data cable from the drive. ① Remove the screws of the drive. Remove the hard disk drive from the bay. Note Note that special screws with inch threads (screw designation 6-32x3/16''-St-G3E) are used. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 131: Removing/Installing An Ssd Drive

    Remove the hard disk cover and place it on the device. Connect the power supply cable and the data cable to the SSD drive. Fasten the SSD drive with four (4) ① screws Mount the hard disk cover. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 132: Installing/Removing An On-Board Compact Flash Card

    11.7.5 Installing/removing an on-board Compact Flash card Note We highly recommend that use use approved SIMATIC Compact Flash cards. Siemens disclaims any liability for impairment of functions caused by the use of third-party cards. Memory expansion options The device features a slot for Compact Flash cards types I / II.
  • Page 133 11.7 Expansion and parameter assignment Opening the board slot How to install a Compact Flash card Remove the screws. Slide the cover plate of the module slot towards the DVI connection and lift it out. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 134 The Compact Flash slot is coded against reversed insertion. Insert the Compact Flash card so that its label side is facing the front panel of the PC. NOTICE If the Compact Flash card meets resistance, flip it over. Never insert the Compact Flash card with force. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 135: Installing/Removing An Additional Compact Flash Card

    11.7.6 Installing/removing an additional Compact Flash card Note We highly recommend that use use approved SIMATIC Compact Flash cards. Siemens disclaims any liability for impairment of functions caused by the use of third-party cards. Preparation Disconnect the device from the mains.
  • Page 136 How to install the Compact Flash card in the Compact Flash adapter Remove the hard disk cover. Lift out the Compact Flash adapter module and lay it on the device. ① Remove the screws and remove the CompactFlash latch. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 137: Removing And Installing Hardware Components

    Removing and installing hardware components 11.8.1 Repairs Repairing components Only authorized personnel are permitted to repair the device. WARNING Unauthorized opening and improper repairs may lead to material damage and hazards to users. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 138: Preventive Maintenance

    Disclaimer of liability All technical data and approvals apply only to expansion units which are released by SIEMENS. Siemens disclaims any liability for impairment of functions caused by the use of third-party devices or components. Tools You can perform all installation tasks on the device using Torx T6, T10, T15 and T20 screwdrivers.
  • Page 139 2. Isolate the device from mains and disconnect all connection cables. Note You can also replace the battery while the device is running; do not touch anything with the device in this case. We recommend switching off the device beforehand. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 140 Steps for replacing the battery Open the battery compartment. Remove the battery holder. Detach the cable. Remove the old battery. Fasten the new battery and reinsert the battery holder. Close the battery compartment. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 141: Removing/Installing The Power Supply

    How to remove the power supply module Remove the drive bay module for the hard disk and DVD burner. ① Loosen the screws and remove the power supply cover. ① Remove the screws (Torx T10). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 142: Installing / Removing The Bus Board

    Remove all modules from the slots. Lift out the drive bay module for hard disks and the DVD burner. ① Loosen the screws and remove the power supply cover. Remove the power supply. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 143: Installing / Removing The Motherboard

    2. Open the device (Page 121). Removing the motherboard How to remove the motherboard Remove the drive bay module for the hard disk and DVD burner. ② Remove the screw . Remove the ① module bracket SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 144 Disconnect all cables from the motherboard, noting down their positions while doing so. ① ② Remove the screws (6 pieces) and then the screws (4 pieces). Remove the processor heat sink. Remove the hexagon bolts (6 pieces) from the ports. Remove the motherboard. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 145: Installing / Removing The Equipment Fan

    2. Open the device (Page 121). Removing the fan How to remove the fan ① Pull the fan plug from the motherboard. ① Loosen the four plastic rivets the enclosure. Take the fan out of the enclosure. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 146: Installing / Removing The Power Supply Fan

    Preparations 1. Disconnect the device from the mains. 2. Open the device (Page 121). 3. Remove the power supply. Removing the fan How to remove the fan ① Pull out the fan connector SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 147: Processor Replacement

    Operation of the CPU is not possible. As the processor is soldered on the motherboard, it has to be completely replaced. Please observe the information in Section Installing / removing the motherboard (Page 143). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 148: Reinstalling The Software

    Restoration of the entire C drives: (system) and D: or only drive C: is possible. This allows you to retain any user data on drive D:. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 149 SATA port number. Example: P3 - OPTIARC DVD-ROM DDU1681S 6. Follow the on-screen instructions. NOTICE All existing data, programs, user settings, authorizations and license keys on the drives will be deleted and are thereby lost. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 150: Installing Windows

    F12 key. The boot menu displayed after initialization indicates all boot devices. 2. Select the DVD drive. Follow the instructions on the screen until the "Siemens SIMATIC Recovery" window is displayed. When using the recovery function of Windows 7, confirm that you want to boot from DVD immediately at startup.
  • Page 151 Information on partitioning of the data carrier in the delivery state is provided in the following table. Partition Name Size File system First SYSTEM 25 GB NTFS not compressed Second DATA Remainder NTFS not compressed SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 152: Installation Of Windows 7

    The language of the installation program and the operating system you want to install has been preset to English. You can change the language of the operating system after the installation. You can find information on this in section: Auto-Hotspot. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 153: Setting Up The Language Selection By Means Of The Multilanguage User Interface (Mui)

    2. You can make the desired changes in the "Regional Settings", "Languages" and "Advanced" tabs. Installing new language packages 1. Start the "MUISETUP.EXE" program in the "MUI" folder from the Recovery DVD. All languages that can be installed are displayed. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 154: Recovery Of Windows 7

    There is a full graphical user interface available for recovery of Windows 7. It may take several minutes before the first input window appears. In this window, you can set the time and currency formats and select the keyboard language. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 155 Options Meaning Drive options (advanced) Further functions are displayed with which you can set up the hard disk. Load Driver To add new drivers, for example the driver for RAID. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 156 SYSTEM 25 GB NTFS not compressed Second Windows 7 DATA Remainder NTFS not compressed Following a required reboot, Windows will be installed on the hard disk. This process takes at least 20 minutes. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 157 You will find the necessary files on the recovery DVD in the "Languagepacks" folder. Start > Control Panel > Clock, Language, and Region > Change display language > Regional and Language options > Keyboards and Languages Additional languages can be integrated through Windows Update. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 158: Installing Drivers And Software

    Additional information on this is available in the section "Installation of drivers and software". 11.9.8 Installing the optional burner or DVD software Information about installation of the burner / DVD software is available on the supplied CD. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 159: Update Installation

    Contact the manufacturer to obtain updates of drivers and application programs you purchased from third-party vendors. Note Before you install new drivers or operating system updates for Windows versions, set the default language to US English in the regional settings for menus and dialogs. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 160: Data Backup / Subsequent Modification Of Partitions

    Modifying the partitions In order to modify partitions, we recommend using the software tool "SIMATIC IPC Image & Partition Creator". The software can be ordered from the SIEMENS online ordering system. Detailed information about using this tool is available in the manufacturer documentation of the "SIMATIC IPC Image &...
  • Page 161: Cp 1616 Onboard

    Several reboots can be carried out after a BIOS update. These reboots are initiated by the Management Engine (ME). The reboots are required by the ME to adapt itself to the changes in the BIOS update. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 162: Bios Recovery

    "Recovery" interface. 4. Close the device cover. 5. Place the Siemens BIOS Update USB stick into an USB slot of the device front. 6. Connect the power supply and switch on the device. Recovery is executed automatically and cannot be interrupted or operated. The recovery progress will be displayed on the screen.
  • Page 163: Alarm, Error, And System Messages

    Incorrect active boot partition • Wrong drive settings in SETUP • Hard disk is not connected / defective • Error - Realtime clock has lost Clock chip error. power Contact your technical support team. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 164: Introduction To The Bios Beep Codes

    Meaning Determine RAM size 12.3 BIOS beep codes The following section lists the POST codes relevant to users in the sequence in which they occur: Contact Customer Support (http://www.siemens.com/automation/service&support) for information on all other POST codes. Display Meaning Description Remedy...
  • Page 165 Volume PEI_SIO_INIT Super I/O initial Initialization of the Service case Super I/O PEI_CPU_REG_INIT CPU Early Initial Initialize CPU Register Service case PEI_CPU_AP_INIT Multi-processor Multi processor Service case Early initial initialization SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 166 Initialization of the Service case Initial variable service DXE_VARIABLE_INIT_FAIL Fail to initial Failure to initialize the Service case Variable Service variable service BDS_CONNECT_LEGACY_ROM Dispatch option Callup of the Legacy Service case ROMs Option ROMs SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 167 Legacy 16 boot Start Legacy 16 boot Service case entry P0ST_BDS_JUMP_BOOT_SECTOR Try to Boot with Boot with INT 19 Service case INT 19 ASL_WAKEUP_S5 System wakeup Reboot from operating Service case from S5 state S5 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 168 SATA controller Initialization of the Service case initial SATA controller BDS_START_ISA_ACPI_CONTROLLER SIO controller Initialization of the Service case initial Super IO BDS_START_ISA_BUS ISA BUS driver Initialization of the ISA Service case initial bus driver SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 169 Service case garbage memory collection and reclaim operation PEI_PROGRAM_CLOCK_GEN Clock Generator Initializations of the Service case Initial clock generator PEI_IGD_EARLY_INITIAL Internal Graphic First initialization of the Service case device early graphic connection initial, PEI_IGDOpRegi SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 170 RAM PEI_FINDING_DXE_CORE Loading DXE Loading DXE (Driver Service case core Execution Environment) program PEI_GO_TO_DXE_CORE Enter DXE core Start DXE program Service case Special codes The BIOS does not generate any beep codes. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 171: Troubleshooting/Faqs

    If you are using an adapter or extension for the mouse lead, check the connectors. Should the mouse cursor still not be visible on- screen after completing these checks and measures, contact technical support. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 172 "Boot device not found" is boot priority in the BIOS setup or is Boot menu of the BIOS setup or permit boot device displayed excluded as a boot device in the boot priority SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 173: Problems When Using Modules Of Third-Party Manufacturers

    Replace this Different connector pin • module with a Siemens module or contact the module assignments supplier. Contact Technical Support if the PC still crashes. use a larger power supply.
  • Page 174 Troubleshooting/FAQs 13.3 Display a temperature error by means of the DiagBase application SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 175: Technical Data

    1 x PCI 290 mm long and 1 x PCI Express x16 185 mm long Maximum permissible 5 V/2 A or 3.3 V/3 A, 12 V/1 A, -12 V/0.05 A current consumption per The accumulated power consumption (all slots) may not exceed 30 W PCI slot SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 176 A small number of faults in the display is unavoidable. However, the displays do comply with the described quality standards of the ISO standard 13406-2, class 2. Bad pixels Permissible number Permanently bright, dark pixels ≤ 12 • • Permanently bright, green pixels ≤ 5 • • SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 177 Touch panel Touch panel Weight of complete unit 11.9 kg 16.0 kg 12.5 kg 14.4 kg 16.8 kg 15.0 kg Control unit 4.9 kg 9.0 kg 5.5 kg 7.4 kg 9.8 kg 8.0 kg SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 178 ± 2 kV, (according to IEC 61000-4-4; burst) ± 1 kV; (according to IEC 61000-4-5; surge sym.) ± 2 kV; (according to IEC 61000-4-5; surge asym.) Magnetic field 100 A/m, 50 Hz according to IEC 61000–4–6 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 179 5 g, 30 ms (3 cycles per axis) • • Storage, transportation 250 m/s approx. 25 g, 6 ms (3 cycles per axis) • • Noise emission < 55 dB(A) according to DIN 45635-1 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 180: Ports And Status Displays

    1x LED for Profinet (optional) Electrical isolation within the safety extra-low voltage circuit (SELV) LAN interfaces are numbered on the enclosure to provide unique identification. The ∗2 operating system numbering may deviate from this. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 181: Current/Power Requirements Of The Device

    Max. 37 W Internal front interface (on panel 0.23 A max. 2.21 A max. Max. 53 W devices) 14.4 AC voltage supply Technical data Degree of protection IP20 (in installed state) Protection class VDE 0106 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 182 * total of 90 W permitted +12 V / 6.5 A (8 A peak) -12 V / 0.3 A Secondary power output Max. 150 W Power Good signal of the AC power supply SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 183: Dc Power Supply

    * total of 90 W permitted +12 V / 6.5 A (8 A peak) -12 V / 0.3 A Secondary power output Max. 150 W Power Good signal of the DC power supply SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 184: Keyboard Table

    L Shift/R Shift É L Gui/R Gui Start Windows Explorer — L Shift/R Shift L Gui/R Gui Find folder and file — L Shift/R Shift — L Shift/R Shift — L Shift/R Shift SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 185 R Alt+L Shift/R Ö Shift L Ctrl/R Ctrl Printing — L Shift/R Shift R Alt ä R Alt+L Shift/R Ä Shift — L Shift/R Shift R Alt ® L Gui/R Gui Display "Run" dialog — SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 186 Ü Shift — L Shift/R Shift R Alt æ R Alt+L Shift/R Æ Shift L Ctrl/R Ctrl — L Shift/R Shift R Alt ¡ R Alt+L Shift/R ¹ Shift — L Shift/R Shift SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 187 Escape — Escape Backspace — Backspace — Space — Space — L Shift/R Shift R Alt ¥ — L Shift/R Shift R Alt × R Alt+L Shift/R ÷ Shift — L Shift/R Shift SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 188 L Shift/R Shift R Alt ¿ Caps Lock — Caps Lock — L Shift/R Shift L Ctrl/R Ctrl — L Shift/R Shift L Ctrl/R Ctrl — L Shift/R Shift L Ctrl/R Ctrl — SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 189 — Page Down Right Arrow — Right Arrow Left Arrow — Left Arrow Down Arrow — Down Arrow Up Arrow — Up Arrow Num Lock — Num Lock Keypad / — Keypad / SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 190 — Left Shift Left Alt — Left Alt Left GUI — Left GUI Right Control — Right Control Right Shift — Right Shift Right Alt — Right Alt Right GUI — Right GUI SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 191: Dimensional Drawings

    Dimensional drawings 15.1 Dimension drawing IPC Figure 15-1 Dimension drawing IPC SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 192 270.4 270.4 270.4 270.4 270.4 104.5 123.5 123.0 120.3 129.5 121.9 140.9 10.5 10.5 10.5 10.5 10.8 41.9 30.0 53.4 24.4 18.4 350.6 369.0 369.1 366.5 375.6 59.3 48.1 70.8 41.8 38.1 35.8 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 193: Dimensional Drawings For The Installation Of Expansion Modules

    15.2 Dimensional drawings for the installation of expansion modules 15.2 Dimensional drawings for the installation of expansion modules Figure 15-3 Short PCI or PCI Express modules Figure 15-4 Maximum size of PCI module SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 194 Dimensional drawings 15.2 Dimensional drawings for the installation of expansion modules SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 195: Detailed Descriptions

    The essential components of the motherboard are the processor and the chip set, two slots for memory modules, internal and external interfaces and the Flash BIOS. ① Processor heat sink ② Slot for the bus board ③ Two memory module slots SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 196: Technical Features Of The Motherboard

    - supports NCQ (Native Command Queuing; SATA II property) Flash memory CompactFlash card Solid-state drive RAID Onboard Serial ATA Intel BD82QM57 • RAID 0, 1, 0+1 DVD Burner connection, Serial ATA UDMA-capable, ATA33 • SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 197 4088 bytes Ethernet 2: Intel 82574 L, supports • jumbo frames up to 9014 bytes Electrically isolated within the safety extra-low voltage circuit (SELV) Optional product variant Depends on the selected device configuration SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 198: Position Of The Interfaces On The Motherboard

    The motherboard of the device features the following interfaces: ● Interfaces for the connection of external devices ● Interfaces for internal components (drives, bus boards etc.) Figure 16-1 Interfaces on the motherboard * Optional product variant SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 199: External Ports

    Short description Meaning Input / Output + 5 V (fused) Output – Data Data channel Input / Output + Data Data channel Input / Output Ground – The connectors are of type A. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 200 Signal line A of the MPI module Input/output RTS_PG RTS output signal of the MPI module. The Output control signal is "1" when the programming device is sending. Shield on connector casing Optional product variant SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 201 Input / Output BI_DC- Bi-directional data C- Input / Output BI_DB- Bi-directional data B- Input / Output BI_DD+ Bi-directional data D+ Input / Output BI_DD- Bi-directional data D- Input / Output Shield – SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 202 DDC clock Input / Output DDC CLK DDC data Input / Output VSYNC Vertical synchronizing pulse Output TX1N TDMS data 1- Output TX1P TDMS data 1+ Output Ground – Unassigned – Unassigned – SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 203 26, 25 CD1#, CD2# Card detect (not connected) 33, 40 VS1#, VS2# Voltage sense (not connected) DMARQ DMA request (input) DMACK# DMA acknowledge (output) Write enable 1, 50 Ground 13, 38 + 3.3V power SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 204: Internal Interfaces

    X2400 Voltage tap ( = 3V) of the backup battery, 2-pin, male connector USB interface Internal USB channel 6 and 7, 10-pole male connector USB interface Internal USB channel 9, upright USB socket SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 205 Pin assignment of the supply for the serial ATA drives X26, X27, X28, X29, X30 Pin no. Short description Meaning Input / Output +12 V Voltage supply Output Ground – Ground – +5 V Voltage supply Output +3.3 V Voltage supply Output SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 206: Front Ports

    The maximum cable length is 50 cm at a transmission rate of 455 MHz. Special cable properties are required for the differential cable pairs specified by the LVDS specification. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 207 Ground Ground RXIN12- LVDS input signal bit 2 (-) Output RXIN12+ LVDS input signal bit 2 (+) Output Ground Ground RXCLKIN1- LVDS clock signal (-) Output RXCLKIN1+ LVDS clock signal (+) Output Ground SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 208 Pin no. Short description Meaning Input / Output Ground P12V Inverter voltage supply Output BL_ON Backlight on (5 V = On) Output P5V_fused +5 V (fused) Output Ground P3V3_fused +3.3 V VCC (fused) Output SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 209 USB5 USB5_M Input / Output USB5 USB5_P Input / Output Ground Shield Shield Note For detailed information on the pin assignments of the interfaces, please contact Customer Support (http://www.siemens.com/automation/service&support) or the Repair Center. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 210: Bus Board

    Slot 2 ③ Slot 1 Variant 2 has one PCI and one PCI Express slot. ① Slot 1 PCI ② Slot 2 PCI Express x16 ③ 12V power supply connection for WinAC module SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 211: Pci Slot Pin Assignment

    AD[26] AD[25] Ground +3.3V AD[24] C/BE[3]# IDSEL AD[23] +3.3V Ground AD[22] AD[21] AD[20] AD[19] Ground +3.3V AD[18] AD[17] AD[16] C/BE[2]# +3.3V Ground FRAME# IRDY# Ground +3.3V TRDY# DEVSEL# Ground Ground STOP# LOCK# +3.3V SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 212: Pin Assignment 12 V Power Supply Connection For Winac Module

    Output Ground Ground +5 V 5 V voltage Output 1) max. permissible current: 1 A; with this power demand the total power demand for the PCI slots are not allowed to be exceeded. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 213: Pci Express Slot X16 Pin Assignment

    PCIE0_ECLK PCIEX16_TX_P(15) PCIE0_ECLK_N PCIEX16_TX_N(15) PCIEX16_RX_P(15) SDVO_CTRLCLK PCIEX16_RX_N(15) PCIEX16_TX_P(14) n.c. PCIEX16_TX_N(14) PCIEX16_RX_P(14) PCIEX16_RX_N(14) PCIEX16_TX_P(13) PCIEX16_TX_N(13) PCIEX16_RX_P(13) PCIEX16_RX_N(13) PCIEX16_TX_P(12) PCIEX16_TX_N(12) PCIEX16_RX_P(12) n.c. PCIEX16_RX_N(12) SDVO_CTRLDATA n.c. PCIEX16_TX_P(11) n.c. PCIEX16_TX_N(11) PCIEX16_RX_P(11) PCIEX16_RX_N(11) PCIEX16_TX_P(10) PCIEX16_TX_N(10) PCIEX16_RX_P(10) PCIEX16_RX_N(10) SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 214 PCIEX16_TX_N(7) PCIEX16_RX_P(7) PCIEX16_RX_N(7) PCIEX16_TX_P(6) PCIEX16_TX_N(6) PCIEX16_RX_P(6) PCIEX16_RX_N(6) PCIEX16_TX_P(5) PCIEX16_TX_N(5) PCIEX16_RX_P(5) PCIEX16_RX_N(5) PCIEX16_TX_P(4) PCIEX16_TX_N(4) PCIEX16_RX_P(4) PCIEX16_RX_N(4) PCIEX16_TX_P(3) PCIEX16_TX_N(3) PCIEX16_RX_P(3) PCIEX16_RX_N(3) PCIEX16_TX_P(2) PCIEX16_TX_N(2) PCIEX16_RX_P(2) PCIEX16_RX_N(2) PCIEX16_TX_P(1) PCIEX16_TX_N(1) PCIEX16_RX_P(1) PCIEX16_RX_N(1) PCIEX16_TX_P(0) PCIEX16_TX_N(0) PCIEX16_RX_P(0) n.c. PCIEX16_RX_N(0) n.c. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 215: System Resources

    Start > Enter "cmd" in the search function, then enter "msinfo32" in the input 16.3.2 System resources used by the BIOS/DOS The following table describes the system resources for the factory state of the device. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 216: I/O Address Allocation

    0300 031F Not used 0320 032F Not used 0330 033F Not used 0340 035F Not used 0360 0367 Not used 0370 0371 0372 0375 Not used 0376 0376 Secondary EIDE channel SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 217 SATA RAID Controller 8C00 FEFF 29288 Not used for SATA RAID 8870 8897 PATA RAID Controller 8898 FEFF 30311 Not used for PATA RAID 1880 886F 28655 Not used FF00 FF0F EIDE bus master register SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 218: Interrupt Assignments

    IRQ 0 to 15 in PIC mode. A specific assignment can not be enforced. Interrupt in PIC and APIC mode Interrupt in APIC mode BIOS Default Interrupt in PIC mode (e.g. DOS) Figure 16-3 Interrupt assignment in PIC mode SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 219: Exclusive Pci Hardware Interrupt

    Requirement: The modules in the PCI slots each require only one interrupt Requirement: VGA and PCI Express do not require an interrupt Requirement: VGA does not require an interrupt and Ethernet1 is disabled SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 220: Memory Address Assignments

    Motherboard resources FED1 C000 FED1 FFFF Motherboard resources FED2 0000 FED3 FFFF 128K Motherboard resources FED9 0000 FED9 3FFF Motherboard resources FEE0 0000 FEEF FFFF Motherboard resources FF00 0000 FFFF FFFF Motherboard resources SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 221: Addresses Used By Sram

    Your device configuration is preset for operating with the included software. You should only change the default values if you have modified the technical configuration your device, or if a fault occurs when the unit is powered up. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 222: Starting Bios Setup

    The following message appears on the screen: – Press F2 go to Setup Utility – Press F12 go to Boot Manager 2. Press the F2 key while the BIOS prompt appears on the screen. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 223: Bios Setup Menus

    SETUP item from the "item-specific help" part of the respective menu. Figure 16-5 SETUP Main menu (example) ① ④ Header Help window ② ⑤ Menu bar Command line ③ System information SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 224 The behavior of the device after a power failure and after wake events is specified here. Boot This is where the boot priority is specified. Version This shows device-specific information (such as the release version). Exit Used for terminating and saving. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 225: Main Menu

    [+] and [-] keys to modify the time setting Hour: Minute: Second and for the date. Month/Day/Year You can navigate between the entries in the date and time fields (for example, from hour to minute) using the ENTER key. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 226: Advanced Menu

    Chipset Configuration Extended chipset configuration. CPU Configuration Configuration of CPU parameters Active Management Technology Support Configuration of the AMT functionality Fan control Activate/deactivate fan control. If deactivated, the fans always run at full speed. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 227 Enable or disable the onboard Ethernet 2 interface. Ethernet 1 Address: Display the MAC address of Ethernet 2 PCI – MPI / DP / PROFINET: Enable or disable the onboard MPI/DP or PROFINET interface. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 228 Submenu for SATA Port 2 configuration Serial ATA Port 3 Submenu for SATA Port 3 configuration Serial ATA Port 4 Submenu for SATA Port 4 configuration Serial ATA Port 5 Submenu for SATA Port 5 configuration SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 229 CRT+LFP: VGA screen and local display • Forced CRT Enabled: The CRT/VGA interface is active even when no monitor is connected, e.g. for AMT headless mode. Disabled: The CRT/VGA interface is only active when a monitor is connected. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 230 Figure 16-10 Submenu Advanced menu > USB Configuration Entry Meaning USB Port0 -10 Enable: USB port is activated. • Auto: USB port is deactivated when no device is plugged. • Disable: USB port is deactivated. • SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 231 Output Port 80 status display to PCI bus or LPC BUS (status display at the device). VT-d Enable or disable advanced support for virtualization technology "DIRECT I/O" HPET Enable High Precision Event Timer SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 232 Disabled: Single Core operation • HT Support Auto: Use hyperthreading, if available. • Disabled: Hyperthreading disabled. • Use XD Capability Enable or disable XD (Execute Disable) Capability. VT Support Enable or disable virtualization functionality "Vanderpool Technology". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 233: Advanced, Active Management Technology Support" Menu

    CIRA timeout for connection establishment with MPS (Manageability Presence Server / "vPro Enabled Gateway"). Un-Configure ME Resets all the values of the MEBx to their defaults (see section "Reset with Un-Configure"). USB Configure Enable and disable the USB configuration (provisioning). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 234 Opens the submenu with the general ME settings (see "ME General Settings"). Intel(R) AMT Configuration Opens the submenu for the AMT settings (see "ME General Settings"). Exit Exits the MEBx. ME general settings SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 235 Kerberos, time stamps of events. Period of validity: 1.1.2004 – 4.1.2021. Power Control Specifies the power states S0, S3, S4 of the computer in which the ME is activated. Previous Menu Return to the main menu. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 236 AMT PC. The remote user must enter this number on the help desk PC before the KVM connection can be opened. Previous Menu Return to the main menu. See also Resetting with Un-configure (Page 250) SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 237: Security Menu

    Set a User password for limited access to the SETUP. This field opens the password input dialog. Logged on users can change the password, or clear and thus deactivate it by pressing "RETURN". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 238: Power Menu

    [Last State]: If the device was switched on when the power • failure occurred, the device switches on when the voltage is restored. Otherwise, the device remains switched off when the voltage is restored. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 239: Boot Menu

    Enable or disable booting of the LAN1. PXE Boot to LAN 2 Enable or disable booting of the LAN2. EFI> Set order of the EFI boot media Legacy> Set traditional boot order (Normal, Advanced, Advanced Placeholder). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 240 The booting position of the component can be moved freely. During booting the component at the first position (highest booting priority) is used. If the component is not available, booting is carried out from the next component in the list. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 241 Detailed descriptions 16.4 BIOS-Setup Figure 16-17 Submenu "Boot / Legacy / Normal Boot Menu " Figure 16-18 Advanced Placeholder SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 242: Version Menu

    16.4.10 Version Menu This menu contains system information which should be made available to Technical Support. Figure 16-19 Version menu SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 243: Exit Menu

    The set parameters are saved as a USER profile. Load Manufacturer Profile The manufacturer parameters are downloaded to the SETUP device. Profiles Display field: Displays the active profile (Standard, User, Manufacturer) with which the device is currently operating ... SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 244: Bios Setup Default Settings

    Main System Time hh:mm:ss System Date MM/DD/YYYY System parameters Default settings Local settings Advanced>Peripheral Configuration Internal COM 1 Auto Onboard Ethernet 1 Enabled Onboard Ethernet 2 Enabled PCI – MPI / DP Enabled SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 245 Enabled USB Port6 Enabled USB Port7 Enabled USB Port8 Enabled USB Port9 Enabled USB Port10 Enabled System parameters Default settings Local settings Advanced>Chipset Configuration Port 80h Cycles LPC Bus VT-d Enabled HPET Enabled SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 246 Advanced Fan control Enabled System parameters Default settings Local settings Security Supervisor Password Not installed User password Not installed Set Supervisor Password Inactive (no password assigned) Set User Password Inactive (no password assigned) SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 247 PXE Boot to LAN 2 Disabled System parameters Default settings Local settings Boot > EFI System parameters Default settings Local settings Boot > Legacy Normal Boot Menu Standard System parameters Default settings Local settings Exit Profile: Standard SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 248: Active Management Technology (Amt)

    BIOS setup. Afterwards the Intel® Management Engine (Intel® ME) has to be activated and set for AMT. You make additional settings in the Management Engine: ● Configuring the network for access via AMT ● Creating a password SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 249: Enabling Amt, Basic Configuration

    The underscore _ and the space characters are valid password characters, however they do not increase password complexity. 9. Enable "Intel (R) AMT Configuration > Manageability Feature Selection". 10. Enable "Intel (R) ME General Settings > Activate Network Access". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 250: Advanced Settings

    3. After the restart, a user prompt appears asking whether you really want to discard all the settings in the management engine: 4. Confirm with "Y". On a German keyboard, this means pressing the key. The device continues to boot with the factory settings of the management engine. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 251: Determining The Network Address

    To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Enable "Opt-in configurable from remote IT". SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 252: Communications Processor Cp 1616 Onboard

    Three RJ45 connectors The CP 1616 is connected to the LAN (Local Area Network) via one of the three RJ45 sockets of the PC. These three sockets lead to the integrated realtime switch. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 253: Typical Communication Partners

    IO base user program interface. Data traffic is routed via the CP 1616 onboard communication processor to a PC as PROFINET IO controller, or to an S7-400 automation system with CP 443-1 over Industrial Ethernet. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 254: Firmware Loader

    This section will familiarize you with the application area and use of the firmware loader. You can find additional, detailed information about the individual loader variants in the integrated help of the program. Firmware This refers to the system program in the SIMATIC NET modules. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 255 The firmware loader can use this information to check if the firmware is compatible to the device. Read the information provided along with the loader file, for example, in the readme file. This information is also displayed in the firmware loader when the FWL file is loaded. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 256: Loading Firmware

    NOTICE Ensure that the loader file you are using for the update is suitable for the version of firmware on your module. If you have any doubts, contact your local Siemens consultant. NOTICE Be aware that aborting the loading process may result in an inconsistent state in your module.
  • Page 257 MAC addresses (always in direct sequence). The first two are shown in the BIOS. Figure 16-21 Advanced menu Peripheral Configuration Example The lower MAC address at "Profinet" is provided for Layer 2 communication, while the second one is used for Ethernet/PROFINET communication. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 258: Further Actions In Step 7/Ncm Pc

    The rest of the procedure is described in the "Commissioning PC Stations" manual (on the Windows PC that also contains STEP 7/NCM PC: Start > Simatic > Documentation > English > Commissioning PC Stations). SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 259: Appendix

    Radio interference is possible This is a system of Class A. The equipment may cause RF interference in residential areas. In this case, the operating company may be held liable for taking appropriate measures. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 260: Standards, Certificates And Approvals

    The currently valid approvals are to be found on the device's rating plate. ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets DIN ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 261 Cet appareil numérique de la classe A est conformé à la norme NMB-003 du Canada. AUSTRALIA This product meets the requirements of the standard EN 61000-6-4:2007 Generic standards - Emission standard for industrial environments. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 262 The electrostatic sensitive components/modules are commonly referred to as ESD devices. This is also the international abbreviation for such devices. ESD modules are identified by the following symbol: SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 263 The figure below shows the maximum electrostatic voltage which may build up on a person coming into contact with the materials indicated. These values correspond to IEC 801-2 specifications. Figure A-1 Electrostatic voltages on an operator SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 264: Service And Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (http://www.siemens.com/automation/service&support) ● Support request form (http://www.siemens.com/automation/support-request) ● After-sales information system for SIMATIC PC / PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.siemens.com/automation/partner) ● Training center (http://www.sitrain.com) ●...
  • Page 265: List Of Abbreviations

    Complementary Metal Oxide Complementary metal oxide semiconductors Semiconductors Certificate of authentication Microsoft Windows Product Key Certificate of License License authorization Communications Port Term for the serial interface Communication Processor Communication computer Central Processing Unit SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 266 Programmable Read-Only Memory Enhanced Parallel Port Bi-directional Centronics interface Escape character Control character Enhanced Write Filter Frequently Asked Questions FAQs FAT 32 File Allocation Table 32-bit 32-bit file allocation table FBWF File-Based Write Filter SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 267 Media access control Memory Card Memory card in credit card format Management engine Unit implemented by AMT MEBx Management Engine BIOS Extension User interface for basic configuration of AMT MLFB Machine-readable product designation SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 268 Redundant Array of Independent Disks Redundant hard disk array Restricted Access Location Installation of device in operating facilities with restricted access - for example, a locked switchgear cabinet Random Access Memory Ring Input Incoming call Read-Only Memory SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 269 Designation of the full address of an Internet page Universal Serial Bus UXGA Ultra Extended Graphics Array Graphic standard, maximum resolution 1600x1200 pixels. V.24 ITU-T standardized recommendation for data transfer via serial ports. Positive supply voltage of integrated circuits SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 270 Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. Zero Maintenance Cache Protection Maintenance-free cache unit for saving cache Module contents SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 271: Glossary

    A start sequence, starting when the computer is switched on. The system usually performs some basic hardware checks within the cold start sequence, and then loads the operating system from the hard disk to work memory -> boot SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 272 (e.g. of the monitor, hard disk and CPU), by restricting their activity based on the current system or component load. Energy management is of particular importance for mobile PCs. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 273 The devices connected to a LAN are called nodes. The purpose of networks is the mutual use of files, printers or other resources. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 274 Legacy USB support Support of USB devices (e.g. mouse, keyboard) on the USB ports without driver. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key diskette The license key diskette contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 275 The RAID system is usually implemented in network servers. Recovery DVD Contains the tools for setting up the hard disks and the Windows operating system. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 276 Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The hot key CTRL+ ALT+ DEL can be used to perform a warm start. SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 277: Index

    Connector pin assignment BIOS Setup menus PCI slot, 211 Advanced, 226 Control elements, Boot, 239 Control unit, 20 Main, 225 Separating from the computer unit, 119 Security, 237 couple, 55 Version, 242 Device, 55 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 278 Ethernet RJ45 port, 22 Dimensional drawings Ethernet strain relief, 51 Expansion modules, 193 Expansion, 23 Dimensions, 192 Memory, 123 IPC677C, 192 Expansion modules Directives installing, 125 ESD directives, 262 Expansion slots, 21 External interfaces, 199 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 279 Operating status, Installation information, 28 License key, 149 Stainless steel front, 30 Lithium battery, 139 Installation of operating system Localized information, 47 Windows 7, 152 Low-voltage directive, 260 Windows XP, 150 LVDS Ports, 207 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 280 Operator panels, 44 On/off button, 78 PROFIBUS/MPI, 43 On/Off switch, 77 USB, 43 Open VGA, 43 Device, 122 POST codes Operating, 105 BIOS beep codes, 164 Touch panel, 105 Power factor correction, 182 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 281 Supply voltage, Resistance, 116 Switching on, 79 Resistance to chemicals, 116 Device, 79 Restore DVD, 148 System partition, 149 Restoring the as-delivered condition, 149 System resources, 215 RJ45 Ethernet, I/O address allocation, 216 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...
  • Page 282 Monitoring times, 109 WinAC module Power supply connection, 212 Windows 7 Installation, 152 Recovery, 154 Windows 7 32-bit, 153 Windows 7 64-bit, 153 Windows Security Center, 60 Windows Vista Ultimate Language selection, 95 SIMATIC HMI IPC677C Operating Instructions, 04/2013, A5E02722710-04...

Table of Contents