GE PACSystems ICRXIDIXNE19LCTA User Manual

19" rxi display
Hide thumbs Also See for PACSystems ICRXIDIXNE19LCTA:
GFK-2898B
PACSystems* 19" RXi Display
User Manual
Jan 2016
For public disclosure
Table of Contents
loading

Summary of Contents for GE PACSystems ICRXIDIXNE19LCTA

  • Page 1 GFK-2898B PACSystems* 19" RXi Display User Manual Jan 2016 For public disclosure...
  • Page 2 It is understood that GE may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time. This document is intended for trained personnel familiar with the GE products referenced herein.
  • Page 3 Acronyms and Abbreviations AT Attachment Built-in Test Computer on Module Central Processing Unit DDR3 Double Data Rate (Type Three) DHCP Dynamic Host Configuration Protocol Frame Ground Ground Hard Disk Drive Industrial PC mPCIe Miniature PCI Express Random Access Memory Real Time Clock SATA Serial ATA Secure Digital...
  • Page 4 Safety Symbol Legend Indicates a procedure, condition, or statement that, if not strictly observed, could result in personal injury or death. Warning Indicates a procedure, condition, or statement that, if not strictly observed, could result in damage to or destruction of equipment. Caution Indicates a procedure, condition, or statement that should be strictly followed to improve these applications.
  • Page 5 Contact Information If you purchased this product through an Authorized Channel Partner, then contact the seller directly. General Contact Information Online technical support and GlobalCare http://support.ge-ip.com Additional information http://www.ge-ip.com/ Solution Provider [email protected] Technical Support If you have technical problems that cannot be resolved with the information in this manual, please contact us by telephone or email, or on the web at http://support.ge-ip.com...
  • Page 6 Notes GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 7: Table Of Contents

    Contents 1 Overview ............................. 9 1.1 Specifications ............................11 1.1.1 General Specifications ........................11 1.1.2 Display Specifications........................12 1.1.3 Environmental Specifications ......................13 1.2 User Features ............................14 1.2.1 Power On/Off and User-defined Buttons....................16 1.2.2 Status Indicators ..........................17 1.2.3 Ethernet Port LEDs .........................
  • Page 8 Government Regulations ......................... 43 Index................................. 45 GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 9: Overview

    1 Overview The PACSystems* RXi product line of industrial computers provides an advanced, high-performance control and computing platform. The PACSystems RXi Box Industrial PC (IPC) delivers the flexibility of a computer with the industrial ruggedness of traditional automation controllers. Built with an open and scalable architecture, the RXi platform enables easy connectivity and allows you to maximize application reusability—...
  • Page 10 19" RXi Display (Front View) 19" RXi Display (Rear View) GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 11: Specifications

    1.1 Specifications 1.1.1 General Specifications Specification Item Dimensions 323 x 479.4 x 116.9 mm (12.7 x 18.9 x 4.60 in) Weight 7 kg (15 lb) 1.0 GHz VIA Eden dual core processor Processor 4 GB DDR3 Floating point 64–bit 32 GB mSATA SSD or 250 GB SATA HDD Non-volatile storage Non-volatile storage (NVS) can retain data indefinitely without loss of data integrity.
  • Page 12: Display Specifications

    1.1.2 Display Specifications Specification Item Display Type TFT-LCD Screen Diagonal/Aspect Ratio 470.1 mm (18.5 in) / 16:9 Image Size 409.8 mm (16.1 in) horizontal (H) x 230.4 mm (9.1 in) vertical (V) 1366 H x 768 V pixels WXGA Native Resolution 0.300 mm (0.012 in) Pixel Pitch 16.7 M (RGB 6-bits + Hi-FRC data)
  • Page 13: Environmental Specifications

    1.1.3 Environmental Specifications The RXi Display should be installed in a location that is not exposed to corrosive gases or liquids, rain, or direct sunlight, and that meets the environmental specifications listed in the following Caution table. Note For additional product standards and agency approvals, refer to Appendix Description Item...
  • Page 14: User Features

    1.2 User Features The 9H hardness flat surface cover glass provides a gapless surface that is easy to clean, with superior abrasion resistance, transmissive clarity, and unsurpassed touch sensitivity. Mount the RXi Display on a flat surface in a UL/NEMA Type 1 enclosure that protects against incidental contact and falling dirt.
  • Page 15 Power On/Off SD Card Slot User-defined Overtemp Menu Plus WWAN Minus SATA Drive Wi-Fi Activity Bluetooth Connector Panel Input Power USB 2 Serial RS-232 Ethernet 1 USB 1 Ethernet 2 RXi Display Features Overview GFK-2898B 15 For public disclosure...
  • Page 16: Power On/Off And User-Defined Buttons

    User-defined Button and LED Operation Button Operation Menu User-defined button and white LED. Plus GE-IP FpBtn driver illuminates LED and allows user to select Windows application to open or keycode to select when button touched. Minus GFK-2898B PACSystems 19" RXi Display...
  • Page 17: Status Indicators

    1.2.2 Status Indicators Description Indicator State SATA Drive Status White, blinking Read/write access on SATA drive Over-temperature Internal temperature has exceeded the maximum allowable value. The unit will shut down. Red, solid To recover, let the unit cool, then touch the Power On/Off button.
  • Page 18 Notes GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 19: Pre-Installation Checks And Initial Startup

    If damage is observed (such as bent component leads or loose components), contact GE Intelligent Platforms. Depending on the severity of the damage, it may be necessary to return the product to the factory for repair.
  • Page 20: Initial Startup

    2.2 Initial Startup The following equipment and tools are needed for initial startup: • 24 V dc, 18 – 32 V range, 65 W power supply The power supply used should be a UL listed power source providing voltage isolation with a SELV output, or a Class 2 power source.
  • Page 21 ➢ ➢ To initially start up the RXi Display Attach the power supply output to the RXi Display’s dc power plug using 16 – 24 AWG (1.31– 0.20 mm cross section) wire. For frame ground, use shortest length 16 AWG (1.31 mm ) wire to ground.
  • Page 22: Configuring Ethernet Network Communications

    2.3 Configuring Ethernet Network Communications The default factory settings are Before configuring the RXi Display for operation on a network, consult your network configured to obtain an IP administrator. Duplicate TCP/IP addresses and duplicate computer names on the same address automatically. network can cause network problems.
  • Page 23: Shutting Down The Computer

    2.4 Shutting Down the Computer To avoid damaging files, always shut down Windows software before removing power from the RXi Display. Caution Do not disconnect external devices, such as a flash drive or external DVD drive without first using the Windows Safely Remove Hardware feature to eject the device.
  • Page 24: Disabling Operating System Shutdown

    2.4.1 Disabling Operating System Shutdown The current On/Off button operation requires a touch of approximately 100 ms to begin a controlled Windows shut down. You can change this setting in Windows to require touching the On/Off button for 4 seconds to immediately perform a hard shutdown that forces the unit off without first shutting down Windows.
  • Page 25: Hardware Installation

    3 Hardware Installation 3.1 Mounting and Installation Guidelines The RXi Display is mounted directly onto a panel or enclosure. (Refer to the section Mounting and Installation.) Adhere to the following guidelines for mounting and installation: • The RXi Display should be mounted on a flat surface in a UL/NEMA Type 1 enclosure.
  • Page 26: Mounting And Installation

    3.3 Mounting and Installation The RXi Display is installed as a panel mounted operator interface. One person can install the display without the use of any special tools. Mount the RXi Display on a flat surface in a UL/NEMA Type 1 enclosure. Caution The cooling fins on the back of the RXi Display must be vertical.
  • Page 27: Removal

    Lever Screw Tightening Order 3.3.1 Removal ➢ ➢ To remove the RXi Display Using a #2 Phillips screwdriver, loosen the lever screws. Swing the eight levers on the back of the RXi Display to their retracted position, held in place by a ball plunger. Be careful to not drop the unit when tilting it forward to remove it from the enclosure.
  • Page 28 Notes GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 29: Service And Maintenance

    One #2 Phillips screwdriver • Battery (part number IC690ACC001) The replacement battery must be IC690ACC001 from GE Intelligent Platforms. Using a different battery type than specified may present a high risk of fire or explosion. Warning The battery may explode if mistreated. Do not recharge, disassemble, heat above 100°C (212°...
  • Page 30 ➢ ➢ To replace the RTC battery Remove power from the RXi Display by disconnecting the power cable. Loosen the six captive screws on the back of the RXi Display that are holding the RTM and gently lift the RTM away from the display panel. Loosen the four captive screws that are holding the two RTM sections together and gently separate without stretching the internal power cable.
  • Page 31 Install the replacement battery (IC690ACC001) in the retaining clip with the positive (+) side up. That is, with the + side away from the circuit board. The coin cell must be inserted at an angle to go under the positive terminal clip and then slid into the carrier and snapped into place.
  • Page 32: Disabling The Off Button

    4.2 Disabling the Off Button Disable powering off using the On/Off button by changing the setting of SW1-1, which is located on the display mounting adapter. This prevents unplanned shutdowns caused by accidentally touching the On/Off button. Note The disabled setting affects only the ability to power down the unit. You can still use the On/Off button to power on the unit.
  • Page 33: Connectors And Cabling

    5 Connectors and Cabling This chapter describes the connector layout and cabling requirements on the RXi Display, as well as power and communication connectors. All connectors except the SD card interface are provided on the bottom panel of the RXi Display. Summary of Cabled Ports Recommended Max Shielding...
  • Page 34: Ethernet Communication Ports

    5.2 Ethernet Communication Ports The RXi Display provides two RJ-45 Ethernet network port connectors that support Activity LED 10BASE-T, 100BASE-TX and 1000BASE-T communications. Either or both of these Link LED ports may be attached to other Ethernet devices. Each port automatically senses the data rate (10, 100 or 1000 Mbps), duplex (half duplex or full duplex), and cabling arrangement (straight through or crossover) of the attached link.
  • Page 35: Serial Communication Port

    5.3 Serial Communication Port For maximum cable length, The serial port provides RS-232 communications through a standard RJ-45 female refer to the table Summary of connector with the following pin assignments. Cabled Ports. Shielded cable is required to maintain CE compliance.
  • Page 36: Usb Ports

    5.4 USB Ports For maximum cable length, Two ports are provided for connection of USB 2.0 compatible devices, such as a refer to the table Summary of keyboard, mouse, serial communications or data storage device. Cabled Ports. Double-shielded cable that complies with USB 2.0 is required.
  • Page 37: Video Output Port

    5.5 Video Output Port The video output port is a Video monitor output is provided on the standard 15-pin VGA connector. Shielded cable maintenance port. is required. Video Pin Assignments For maximum cable length, Description Pin # refer to the table Summary of Cabled Ports.
  • Page 38 Notes GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 39: System Recovery

    Windows Operating System To re-install the Windows 7 operating system, refer to http://windows.microsoft.com. RXi Display Device Drivers The drivers and the instructions for installing them are available on the GE Intelligent Platforms Support website, http://support.ge-ip.com. The drivers consist of: •...
  • Page 40 Notes GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 41: Appendix A Certifications And Installation Guidelines

    Self-declaration in accordance with European (EU) Directive Directive 2014/30/EU Refer to the Declaration of Conformity located at http://www.ge-ip.com/support/. Waste Disposal The Electronic Waste Disposal symbol on any electrical or electronic product indicates the product must not be disposed of in a trash bin. Such goods must be returned to the original vendor or to a properly authorized collection point.
  • Page 42: Emc Standards

    EMC Standards The RXi Display complies with the EMC test levels identified in the following table. EMC Emissions Standard Conditions Industrial Scientific and Medical Equipment (Group 1, Class A) CISPR 11 / EN 55011 CISPR 22 / EN 55022 Information Technology Equipment (Class A) Title 47 –...
  • Page 43 Note Changes or modifications to this unit that are not expressly approved by GE Intelligent Platforms could void the user’s authority to operate the equipment.
  • Page 44 Notes GFK-2898B PACSystems 19" RXi Display For public disclosure...
  • Page 45 Disabling Operating System Shutdown 24 Disabling the Off Button 32 Mounting Adapter 26 Drivers 39 mPCIe card 17 Device 39 GE-IP FpBtn 16 Re-installing 39 Network 9, 22, 34 Configuration 22 Network communications 34 Environmental Specifications 13 Ethernet communication ports 34...
  • Page 46 Ethernet communication 34 Ethernet Network 22 Weight 11–12, 25 SD Card 37 Serial communication 35 USB 36 Video ouput 37 Power On/Off 16 Pre-installation Checks 19 Product certifications 41 Real Time Clock (RTC) 29 RJ-45 35 RS-232 35 Battery replacement 29 SD Card Slot 37 Serial communication port 35 Shock 13...
  • Page 48 Automation & Controls from GE 1-800-433-2682 1-434-978-5100 www.geautomation.com GFK-2898B For public disclosure...

This manual is also suitable for:

Pacsystems icrxidixnm19lctaPacsystems icrxidi0nm19lctaPacsystems icrxidi0ne19lctaIcrxidixne19lctaPacsystemsIcrxidixnm19lcta

Table of Contents