Module Select Rear; Monitor Menu - HP 8360 B Series User Manual

Swept signal generator, including options 001, 002, 004, 006, and 008
Table of Contents
Function Group
Menu Map
Description
Programming Codes
See Also
Function Group IrvlOD)
Menu Map 4
Description
M-26 Operating and Programming Reference
POWER and FREQUENCY
2 and 5
This command causes the swept signal generator to examine only
the rear panel source module interface connector to determine
the type of source module (if any) connected. The instrument
frequency limits and multiplier are altered according to the source
module connected. However, the leveling point is
Leveling Point Module to set the swept signal generator to level
at the output of the source module.
An asterisk next to the key label indicates this feature is active.
SYSTem:MMHead:SELect FRONtlREARlNONE
SYSTem:MMHead:SELect?
Analyzer:
NONE
Module Menu
This softkey (Option 002 only) accesses the menu which allows you
to output internally-generated AM and FM waveforms to the rear
panel AM/FM OUTPUT connector. It also accesses the softkeys
which allow you to display the AM depth and FM deviation of the
modulation waveforms.
FM
On/Off
Meter On/Off AM
Outputs the AM waveform to the AM/FM
OUTPUT connector.
Outputs the FM waveform to the AM/FM
OUTPUT connector.
Displays the AM depth of the modulating
signal.
not