Index Information Attention Water Connection Electrical and Gas Connection Installation Chloride Test Total Dissolved Solids (TDS) Test Filtration System Positioning Drainage Connection Detergent Tray (6 Grid, 10 Grid) Oven Cleaner Connection (20 Grid) Water Connection Electrical Oven - Power Gas Oven - Power Due to continuous product research and development, the information contained herein is subject to change without notice.
Information Attention Read through the following instructions carefully before proceeding with the installation. Be sure to follow all relevant standard and local codes. Please contact the Stoddart Service Department at 1300 307 289 if you are having problems with the installation of the unit. Disclaimer: The manufacturer and distributor cannot be held responsible or liable for any injuries or damages of any kind occurred to persons, appliances or others, due to abuse and misuse of this appliance in regards to installation, un-installation,...
Installation IMPORTANT! Selection of the correct water filtration system to suit local water conditions is CRITICAL. Failure to install the correct system according to the following guidelines will void warranty. Chloride Test Remove Titrator from bottle and replace bottle cap immediately. Insert lower end of the Titrator into water to be tested (approx 20mm of water).
Installation Filtration System • After testing the quality of your water supply use the below chart to determine you water filter requirements. Water Supply Test Greater Than 32PPM (Parts Per Million) Chloride (Cl) Less Than 32PPM Less Than 60PPM Greater Than 60PPM Reverse Osmosis Unit Call...
Installation Positioning • The oven must be installed under an extraction canopy that meets AS 1668.2. • To allow access to service panel and protection of the control components, 500mm the left hand side of the Combi oven Minimum must have the following minimum clearance from heat source clearances:...
Installation Drainage Connection • Drain kit is supplied with oven as illustrated. Any modification or extension to the kit must be able to resist temperatures up to 100°C. • Plumb supplied waste pipes to the Tundish. • Tundish needs to be a minimum of 300mm left or right from the oven waste outlet.
Installation Detergent Tray (6 Grid, 10 Grid) • Connect locking pin to underside of oven. • Insert bracket into holes located on underside of oven. • Slide detergent tray between bracket and oven. Secure by rotating the locking pin clockwise 90°. •...
Installation Water Connection • Water connections are labelled on the service panel. • Isolation valve must be installed at the water supply outlet. CWI-1 CWI-2 • CWI-1: The Combi oven requires Filtered Water Non Filtered Water filtered water supplied to its steam generation system.
Installation Electric Oven - Power • Oven is to be wired to the electrical supply by a licensed technician in accordance with AS/NZS60335.1. • Supply must have an isolation switch. Electric Oven Electric Oven • Remove the two screws at the base of the service panel, remove service panel.