Honeywell HPZC10 Series Installation Instructions Manual

Honeywell HPZC10 Series Installation Instructions Manual

Honeywell hydronic pro zone valve control panel
Table of Contents
Available languages

Available languages

HPZC10*
HONEYWELL HYDRONIC PRO
ZONE VALVE CONTROL PANEL
PANEL SPECIFICATIONS
Model
Zones
Transformers
HPZC103
3
(1) 24V 40VA
HPZC104
4
(1) 24V 40VA
HPZC105
5
(2) 24V 40VA
HPZC106
6
(2) 24V 40VA
1
Each transformer is protected with a 2 Amp replaceable fuse.
2
Transformers have a Class 2 output and are rated for 24V, 40VA at 25 °C. It is up to the installer to ensure that the 40VA
transformer rating is not exceeded.
3
All circulator relay connections are rated for 5A full load and 30A locked rotor (1/6 to 1/2HP depending on technology)
at 120VAC. Check circulator plate ratings to ensure full load current is not exceeded.
Electrical Rating for
Main Burner, End
1
Input Power
Switch Burner, and
Zones
120VAC, 60Hz, 1
24V, 1 A
120VAC, 60Hz, 1
24V, 1 A
120VAC, 60Hz, 1
24V, 1 A
120VAC, 60Hz, 1
24V, 1 A

INSTALLATION INSTRUCTIONS

WHAT'S IN THE BOX?
• Hydronic Zone Panel
• Mounting Hardware (3 Screws and 3 Wall Anchors)
• 2, 2-Amp Fuses
• Install Manuals (English & French)
CAUTION
1. Disconnect power supply before beginning
installation to prevent electrical shock or
equipment damage.
2. Use copper conductors only.
3. Use only NEC Class 1 wire for all line voltage
wiring connections. Class 1 wires must be
rated for at least 167 °F (75 °C).
4. For installation by professionals only.
Table 1.
Electrical Rating for
Pump End Switch and
3
Priority Pump
2
120 VAC
5FLA, 30LRA
120 VAC
5FLA, 30LRA
120 VAC
5FLA, 30LRA
120 VAC
5FLA, 30LRA
Type 1 Enclosure
Priority
Zone
Width
Height
Control
Yes
10-1/4"
7-1/2"
Yes
10-1/4"
7-1/2"
Yes
11-3/4"
7-1/2"
Yes
11-3/4"
7-1/2"
33-00360EF-05
Depth
2-1/8"
2-1/8"
2-1/8"
2-1/8"
Table of Contents
loading

Summary of Contents for Honeywell HPZC10 Series

  • Page 1: Installation Instructions

    HPZC10* HONEYWELL HYDRONIC PRO ZONE VALVE CONTROL PANEL INSTALLATION INSTRUCTIONS WHAT'S IN THE BOX? • Hydronic Zone Panel • Mounting Hardware (3 Screws and 3 Wall Anchors) • 2, 2-Amp Fuses • Install Manuals (English & French) CAUTION 1. Disconnect power supply before beginning installation to prevent electrical shock or equipment damage.
  • Page 2: Hang Hole Flow

    HPZC10* MOUNTING Din Rail Flow 1. Mount the DIN rail as specified by DIN rail manufac- Hang Hole Flow turer. 1. Hang the panel on a wall-mounted screw. M37086 Fig. 4. 2. Hang panel by the tabs on the rail’s top edge. M37083 Fig.
  • Page 3: Wiring And Setup

    HPZC10* WIRING AND SETUP Standard Wiring Layout Below wiring diagrams represent a 6 zone valve panel and a 4 zone valve panel. Wiring diagrams for 5 and 3 zone valve panels are identical but with extra zones depopulated. THERMOSTAT THERMOSTAT WIRING TO BOILER WIRING NON-CONNECTED...
  • Page 4 HPZC10* Power Input Circulator Pump Operation Honeywell Hydronic Panels include a convenient wiring The HPZC10* Zone Panels are compatible with common terminal for wiring 120V/60Hz/1Ph power. These circulator pumps and should be wired as shown in the terminals, found at the bottom right side of the panel, following diagrams.
  • Page 5: Boiler Controls

    HPZC10* Boiler Controls Honeywell Hydronic Panels are capable of managing boilers with DHW priority. The panel features two isolated end switches labeled Boiler and End Switch for TT outputs to the boiler. Two slide switches are available to provide simple programing of the end switches to meet the desired application.
  • Page 6: Troubleshooting

    HPZC10* TROUBLESHOOTING This panel provides a status indicator label which is available both when the panel cover is in place and removed. Descriptions of the indicator LED's are shown Valve Fuse Protection below: LED's The Hydronic Zone Valve panels come equipped with T-stat Call indicate the thermostat associated with automatically resettable fuses on each valve output.
  • Page 7: Year Limited Warranty

    Honeywell shall repair or replace it (at Honeywell's option). This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect was caused by damage which occurred while the product was in the possession of a consumer.
  • Page 8 HPZC10* In the U.S.: Honeywell 1985 Douglas Drive North ® U.S. Registered Trademark Golden Valley, MN 55422 © 2018 Honeywell International Inc. 33-00360EF—05 M.S. Rev. 03-18 customer.honeywell.com Printed in U.S.A.
  • Page 9: Contenu De L'emballage

    HPZC10* PANNEAU DE RÉGULATEURS DE VANNES DE ZONE HYDRONIQUE PRO HONEYWELL INSTRUCTIONS D’INSTALLATION CONTENU DE L’EMBALLAGE • Panneau de régulateurs de vannes de zone hydronique • Quincaillerie de montage (3 vis et 3 ancrages muraux) • 2 fusibles de 2 A •...
  • Page 10: Montage

    HPZC10* MONTAGE Rail DIN 1. Montez le rail DIN tel qu’indiqué par le fabricant du Trou de suspension rail DIN. 1. Accrochez le panneau à une vis fixée au mur. M37086 Fig. 4. 2. Suspendez le panneau par les languettes sur le bord supérieur du rail.
  • Page 11: Câblage Et Configuration

    HPZC10* CÂBLAGE ET CONFIGURATION Disposition standard du câblage Les schémas de câblage ci-dessous représentent un panneau de régulateurs de vannes à 6 zones et celui à 4 zones. Les schémas de câblage pour les panneaux à 5 zones et à 3 zones sont similaires. CÂBLAGE DU CÂBLAGE DU VERS LA CHAUDIÈRE...
  • Page 12 Les panneaux hydroniques Honeywell sont également LA POMPE ZONE 1 ALIMENTATION compatibles avec les modules d’interface de l’équipement NO COM NC Honeywell dans les installations ne disposant pas de suffisamment de câblage. POMPE DE ENTRÉE R : 24 V (généralement rouge) POMPE DU L’ECS...
  • Page 13: Vanne De Zone

    HPZC10* Vanne de zone Les panneaux hydroniques Honeywell sont compatibles avec les vannes de zone de 24 V standards et peuvent être raccordés comme indiqué dans les schémas de câblage à la page 3. VANNE DE ZONE À 2 FILS UTILISATION D’UN...
  • Page 14: Contrôles De La Chaudière

    Contrôles de la chaudière Les panneaux hydroniques Honeywell permettent de gérer les chaudières avec une priorité pour l’ECS. Le panneau est doté de deux interrupteurs d’extrémité isolés marqués « Chaudière et interrupteur d’extrémité » pour les sorties TT vers la chaudière.
  • Page 15: Dépannage

    HPZC10* DÉPANNAGE Ce panneau affiche un témoin d’état, que le couvercle soit placé ou non. Une description des témoins est fournie ci- dessous : Fusibles de protection de la vanne Le DEL « Demande du Thermostat » indique qu'il y a une Les panneaux sont munis d'un disjoncteur sur chaque demande de chauffage associé...
  • Page 16: Garantie Limitée De 5 Ans

    GARANTIE LIMITÉE DE 5 ANS Honeywell garantit ce produit contre tout vice de fabrication ou de matériau dans la mesure où il en est fait une utilisation et un entretien convenables, et ce, pour cinq (5) ans à partir de la date d’achat par le consommateur. En cas de défaillance ou de mauvais fonctionnement pendant la période de garantie, Honeywell remplacera ou réparera le produit (à...

This manual is also suitable for:

Hpzc103Hpzc106Hpzc105Hpzc104

Table of Contents