Canadian Solar CS6P-PE Installation Manual

Solar module
Hide thumbs Also See for CS6P-PE:
Headquarters
545 Speedvale Avenue West,Guelph,
Ontario, Canada N1K 1E6
Tel: +1-519-837-1881 Fax: +1-519-837-2550
Germany
Landsberger Strasse 94, 80339 Munich, Germany
Tel: +49 (0) 89-51 996 89-0
Fax: +49 (0) 89-51 996 89-11
Italy
Via Antonio Salandra, 18, 00187 Roma, Italy
Tel: +39 06 4227 2272 Fax: +39 06 4227 4000
Spain
c/ Josefa Valcarcel, 8. 2nd floor, E-28027 Madrid, Spain
Tel: +34 91 320 28 84
Fax: +34 91 320 84 38
Solar Module
Australia
Unit 3B, North Rydelink Business Park 277-283 Lane Cove Road
Installation Manual (IEC)
Macquarie Park, NSW 2113, Australia
Tel:
+61 (2) 9889 4395
Email:
USA
2420 Camino Ramon, Suite 125 San Ramon, CA 94583-4385 USA
Tel: +1-888-998-7739 Fax: +1-925-866-2704
Japan
Round-Cross Shinjuku 5-Chome 8F, 5-17-5 Shinjuku Shinjuku-ku,
Tokyo Japan 160-0022
Tel: 03-5291-8591 Fax: 03-5291-8596
Korea
201, SK HUB Officetel, 708-26, Yeoksam-Dong, Kangnam-gu,
Seoul, Korea
Tel: (02) 539-7541 Fax: (02) 539-7505
Singapore
101 Thomson Road, #15-03 United Square
Singapore 307591
Tel: +65 65729050 Fax: +65 62594690
South Africa
4 Clearview Place, Bentwood Village, Dainfern, 2191, South Africa
Tel: +27-867-750-600 Fax: +27-726-385-885
Middle East
Mohammed Bin Zayed City, Injazat Building, Flat: 321
P.O Box: 39190, Abu-Dhabi, U.A.E
China
199 Lushan Road, Suzhou New District, Jiangsu, China, 215129
Tel: +86 (512) 6690-8088
India
www.canadiansolar.com
www.canadiansolar.com
Table of Contents
loading

Summary of Contents for Canadian Solar CS6P-PE

  • Page 1 Headquarters 545 Speedvale Avenue West,Guelph, Ontario, Canada N1K 1E6 Tel: +1-519-837-1881 Fax: +1-519-837-2550 Email: [email protected] Germany Landsberger Strasse 94, 80339 Munich, Germany Tel: +49 (0) 89-51 996 89-0 Fax: +49 (0) 89-51 996 89-11 Email: [email protected] Italy Via Antonio Salandra, 18, 00187 Roma, Italy Tel: +39 06 4227 2272 Fax: +39 06 4227 4000 Email: [email protected] Spain...
  • Page 2: Table Of Contents

    1.0    GENERAL INFORMATION This general manual provides important safety information relating to the installation, maintenance and handling of CS‐series  CONTENTS    solar modules. System users and professional installers should read this manual carefully and strictly follow the instructions in  the  manual.  Failure  to  follow  these  instructions  may  result  in  death,  injury  or  property  damage.  The  installation  of  solar  1.0    GENERAL INFORMATION ........................  1   modules requires specialized skills and should only be performed by licensed professionals.  1.1    DISCLAIMER OF INSTALLATION MANUAL .....................  1   The word "module" or "PV module" used in this manual refers to one or more CS‐Series Solar Modules.  Please retain this manual for future reference. It is recommended to regularly check on www.canadiansolar.com for the most  1.2    LIMITATION OF LIABILITY  ........................  1   updated version. ...
  • Page 3: Mechanical / Electrical Specifications

    18  CS5E  36  Table 1: Low temperature correction factors table for open‐circuit voltage  CS5H  36  Diode configurations as below:    CS6P-PE CS5P /CS6A-PE                                                       CS6H/CS5C CS5A/CS5T...
  • Page 4: Module Installation

    Do  not  mark  the  modules  with  sharp  instrument.  Particular  attention  should  be  taken  to  avoid  module  backsheet  to  not be connected together to create a voltage higher than the permitted maximum system voltage, even under the worst  come in contact with sharp objects, as scratches may directly affect product safety.  local temperature conditions (see table 1 for correction coefficients to apply for open‐circuit voltage).      Do not leave a module unsupported or unsecured.    A  maximum  of  two  strings  can  be  connected  in  parallel  without  using  over‐current  protection  device  (fuses…)  Do not change the wiring of bypass diodes. ...
  • Page 5: Grounding

    5.2 GROUNDING  6.0    MOUNTING INSTRUCTIONS  Standard modules  Although  the  modules  are  certified  to  safety  class  II,  it  is  recommended  that  they  be  grounded  and  the  module  installation complies with all local electrical codes and regulations.      For a clear understanding of module, please refer to the illustration of a standard module shown below:  The earth grounding connection should be made by a qualified electrician.            Connect module frames to each other using adequate grounding cables, the recommended size is 4‐14mm  (AWG 6‐12)  Reference  Designation  copper  wires.  Holes  provided  for  this  purpose  are  identified  with  a  green  label.  All  the  junctions  on  the  conductive  1 ...
  • Page 6: Method A: Bolting

    6.1    METHOD A: BOLTING  Canadian Solar Inc. warranty may be void in cases where improper clamps or unsuitable installation methods are found.  When installing inter‐modules or end type clamps, take measures so as:  The  mounting  method  has  been  qualified  by  Canadian  Solar  Inc.,  and  the  method  bolting  on  the  short‐side  frame  has  1. Not to bend the module frame  been certified by VDE, the method bolting on long‐side frame has been certified by both VDE and TUV Rheinland.  2. Not to touch or cast shadow on the front glass  Modules should be bolted to support structures through mounting holes located in the frame's back flanges only. Do not  3. Not to damage the surface of the frame  drill additional holes or modify the module frame. Doing so will void the warranty.    4. To ensure the clamps overlap the module frame by at least 5 mm.  Each module must be securely fastened at a minimum of 4 points on two opposite sides, using the most inner mounting  5. To ensure the clamps overlap length is at least 40 mm.  holes.  If  additional  wind  loads  are  anticipated  for  this  installation,  additional  mounting  points  should  be  used.  System  Clamp ...
  • Page 7: Method C: Insertion Systems

    Table 5: Authorized attachments for insertion method    Uplift load ≤ 2400 Pa  Uplift load ≤ 2400 Pa    Downforce load ≤ 2400 Pa 2400 Pa ≤ Downforce load ≤ 4000 Pa  Use 2 insertion profiles running parallel to the long side frame.  Insertion  profile on  Support bar   long side  Authorized range for clamping as a function of model type:  frame  Model type  A1 range (mm)  B1 range (mm)  A2 range (mm)      CS5A  220 – 380  330 – 400  170 – 200  For CS6X series, installations where the downforce load can reach up to a 5400Pa are authorized.  CS5AH  120 – 170  120 – 170  170 – 200  Use 2 insertion profiles running parallel to the short  Use 2 insertion profiles running parallel to the short  CS5P  220 – 390  330 – 400  220 – 270  side frame.    side frame.      CS6A ...
  • Page 8: Maintenance

    7.0    MAINTENANCE  indicated in table 6. Install and tighten the module clamps to the mounting rails using the torque stated by the mounting  hardware manufacturer (in the absence of instructions, Canadian Solar Inc recommends a torque about 15Nm to 20Nm).  Do not change the PV components (diode, junction box, plug connectors).        System designer and installer are responsible for load calculations and for proper design of support structure.    Regular maintenance is required to keep modules clear of snow, bird droppings, seeds, pollen, leaves, branches, dirt spots  Clamp material should be aluminum. EPDM type rubber or similar material should be used between the laminate/clamp  and dust.      and laminate/mounting rail interfaces in order to prevent any damages to the laminate.  If  a  module  has  a  sufficient  tilt  (at  least  15 ),  it  generally  is  not  necessary  to  clean  the  modules  (rainfall  will  have  a  Canadian Solar Inc. warranty may be void in cases where improper clamps or unsuitable installation methods are found. ...
  • Page 9: Annex: Mechanical And Electrical Ratings

    ANNEX: MECHANICAL AND ELECTRICAL RATINGS  Maximum  Operating  Operating  Open Circuit  Short Circuit  Max. Series  Overall  Weight  power  voltage  current    Voltage    Current    Fuse Rating  Dimension  Standard  Test  Conditions  are:  irradiance  of  1  kW/m ,  AM1.5  spectrum,  and  cell  temperature  of  25°C.  The  electrical  Model Type    Pmax  Vmp  ...
  • Page 10 Maximum  Operating  Operating  Open Circuit  Short Circuit  Max. Series  Overall  Maximum  Operating  Operating  Open Circuit  Short Circuit  Max. Series  Overall  Weight  Weight  power  voltage  current    Voltage    Current    Fuse Rating  Dimension  power  voltage  current    Voltage    Current    Fuse Rating  Dimension  Model Type  Model Type      Pmax ...
  • Page 11 Maximum  Operating  Operating  Open Circuit  Short Circuit  Max. Series  Overall  Maximum  Operating  Operating  Open Circuit  Short Circuit  Max. Series  Overall  Weight  Weight  power  voltage  current    Voltage    Current    Fuse Rating  Dimension  power  voltage  current    Voltage    Current    Fuse Rating  Dimension  Model Type  Model Type      Pmax ...

Table of Contents