Sensing and Productivity
Solutions Honeywell
www.honeywell.com.cn
IQ%: The data reflect the impact of the air environment on
an individual’s cognitive ability, as the latter differs according
to the air environment. Higher IQ% means better effect of the
air environment on cognitive ability.
Cognitive ability mainly includes the following: basic mobility,
utilization of mobility, level of focus on assigned task,
information collection, information processing, breadth of
thought, strategy, task orientation and response to crisis.
Note: Cognitive ability differs from individual to individual. IQ% only reflects the
impact of air environment elements on cognitive ability.
An excellent air environment is capable of effectively raising cognitive ability,
thus improving efficiency of various activities.
Range and Precision
Description
Detection Range Precision/Resolution
3
100—999ug/m
±15%
PM2.5
3
3
<100ug/m
±15ug/m
HCHO
0 — 2ppm
0.01ppm(resolution)
(Formaldehyde)
TVOC
0.12— 0.99ppm
0.01ppm(resolution)
2
CO
400 — 2000ppm
1ppm(resolution)
-10 ℃ — 40 ℃
±1 ℃
Temperature
Humidity
0% — 100%
±5%
IQ%
0 — 100%
1%(resolution)
Wireless connection: Wi-Fi IEEE 802.11 b/g/n 2.4GHz
Equipment requirements: Supports mobile phones with Android 4.42 or iOS
8.0 or better
Note: Supports only iPhone5 and later versions
Network Connection
1.
Press and hold Start button on the top of the equipment
for 5 seconds
2.
Press and hold Wi-Fi button and wait for a “tick” sound
from the equipment. The Wi-Fi icon will flash, indicating
that the equipment can now be connected to the
network
3.
Download the App, add new device, connect by
following App’s instruction interface
About App Functions
•
Self-defined alarm value: Default alarm value is factory
setting. For threshold please see explanation above for
App icon. The user can define alarm value according to
its own needs. The equipment’s indicator light and App
on the user’s mobile phone will display in accordance
with the user’s definitions.
•
Alarm clock: 3 alarm clocks can be set for each device
while it is connected to the network. If the alarm clock
rings simply touch the screen or press the Home button
to switch it off. The alarm clock will stop after 10 minutes
if there is no operation.
Interface Instructions
•
Enter the main interface after activating the device.
•
Press the icon light to switch to main screen; it will show
real-time air value.
•
Flashing icon indicates excess values.
•
The device will automatically switch to standby interface
if no operation is being carried out after 3 minutes;
standby mode will also be indicated at App side.Lightly
touch the screen to switch back to the main interface.
92
92
Main interface
Standby interface