ABB 2CSYD0102B User & Installation Manual

ABB 2CSYD0102B User & Installation Manual

Indoor passive infrared detector

Quick Links

4
Indoor passive infrared detector
Product code
2CSYD0102B
Technical specifications
APPLICATION SCOPE
Security
COMMUNICATION
Transmission in FM 868.3 MHz
TECHNOLOGY
RANGE IN FREE AIR
300 m
POWER SUPPLY
Lithium battery 3 V – 1.4 Ah lasting 4
years.
Operation is guaranteed for 30 days from
the low battery notification
DETECTION ELEMENTS
1 IR sensor with Fresnel lens
PROGRAMMING ELEMENTS
1 jumper for test
1 jumper for pulse counting
SIGNAL ELEMENTS
1 red LED
Low battery in the control unit
ANTI-TAMPERING PROTECTION Tamper
Additional data provided by the manufacturer
USAGE TEMPERATURE
-5 ... + 45 °C
USAGE RELATIVE HUMIDITY
Max 95% max (non-condensing)
USAGE ENVIRONMENT
Indoor (sheltered and dry places)
INSTALLATION
Free
SIZES (L x H x W)
70 x 114 x 76 mm
WARNING! Installation must be carried out only by a
qualified electrician
Package contents
no. 1 Indoor passive infrared detector
no. 1 Lithium battery 3 V – 1.4 Ah
no. 2 Self-tapping cross-recessed screws 2.9 x 27 mm
no. 2 Screw anchors ∅ 5 mm
no. 1 Manual
EC Declaration of Conformity
ABB S.p.A., with registered office in Milan - via Vittor Pisani 16,
declares under its own responsibility that the device with product
code
2CSYD0102B
meets
the
essential
electromagnetic
compatibility and security requirements contained in the Directive
R&TTE 1999/5/EC and in the EC Low Voltage Directive
2006/95/CE, as it was designed and manufactured in compliance
with the following harmonized standards: EN 300 220, EN 50130-
4, EN 50131-1, EN 50131-2-2, EN 50131-5-3.
ABB S.p.A. reserve the right to
change the product described in
this manual at any time and
without any advance notice.
ABB S.p.A. - ABB SACE Division
For
further
information:
Viale dell'Industria, 18
http://bol.it.abb.com,
20010 Vittuone (MI) – Italy
DomusTech section or call the
free-phone
Phone: 02.9034.1
Telefax: 02.9034.7609
Printed in Italy
Manual code 2CSM600503D0201 rev 00
2CSYD0102B
Indoor passive infrared
EN
Installation manual
Installation
The installation procedure encompasses the following steps:
1) Device fixing.
2) Operation
settings
(wide
coverage and standard/corridor for \).
3) Power supply and programming.
4) Completion and test.
1. Device fixing
INSTRUCTIONS RELEVANT TO POSITIONING
The device shall be installed:
at a height of 240 cm above the ground or at a height of 90
cm in order to create a corridor for pets (standard heights can
be changed);
far from heat sources and from direct sunlight;
far from electromagnetic sources (e.g. electricity meters,
electric engines);
at a distance of at least 1.5 meters from fluorescent lights;
by avoiding to direct the detector towards moving objects
(e.g. curtains);
by avoiding to direct the detector towards reflecting objects
that could change the coverage area.
at
Figure 1 shows the IR coverage diagrams in flat view and in
number
height view (standard settings and corridor settings for pets)
when the detector is adjusted for a wide coverage angle.
Figure 2 shows similar coverage diagrams related to the detector
adjusted for a long-distance coverage.
General description
detector
The indoor passive infrared detector detects the presence of
intruders in the controlled area.
The detector can be configured in order to provide a wide
coverage angle or a long-distance coverage by keeping the same
sensitivity.
The sensor can operate also in presence of pets.
coverage
angle/long-distance
- 2 -
- 1 -
Figure 1
- 3 -
loading

Summary of Contents for ABB 2CSYD0102B

  • Page 1 POWER SUPPLY Lithium battery 3 V – 1.4 Ah lasting 4 years. ABB S.p.A., with registered office in Milan - via Vittor Pisani 16, Operation is guaranteed for 30 days from 1. Device fixing declares under its own responsibility that the device with product...
  • Page 2 WIDE COVERAGE ANGLE Height Distance (standard) Distance (corridor) LONG-DISTANCE COVERAGE Figure 8 Height Figure 7 3. Power supply and programming Distance 12.5 To program the detector (standard) WARNING! The fixing teeth of the lens are not identical. Remove the detector cover. One is bigger and it has a tapered end that, when the lens is Distance Prepare the control unit to acquire the detector and select...