Ambient Temperature; Visual Characteristics; Test Conditions; Brightness - Philips 160E1SB/93 Service Manual

15.6 inch lcd color monitor
Hide thumbs Also See for 160E1SB/93:
Table of Contents

4. Visual characteristics

Test conditions

Unless otherwise specified, this specification is defined under the following conditions.
(1) Input signal:
(2) Luminance setting:
(3) Warm up:
(4) Ambient light:

(5) Ambient temperature:

Brightness

To follow Panel specification

Image size

Actual display size: Refer to 2.1 LCD PANEL spec.

Brightness uniformity

Set contrast at 100% and turn the brightness to get average above 300 nits at centre of the screen. Apply the Fig 1;
it should comply with the following formula:
Where B_max =Maximum brightness
B_min = Minimum brightness

Check Cross talk(s)

Apply Pattern 2. Set contrast and brightness at 100 %. Measure YA. Then output Pattern 3 and measure YB. The
cross talk value:

White Color adjustment

There are three factory preset white color 9300K, 6500 and sRGB align by FGA function. Apply full gray 64 pattern,
with brightness in 100 % position and the contrast control at 50 % position. The 1931 CIE Chromaticity (color
triangle) diagram (x, y) coordinate for the screen center should be:
Product specification
CIE coordinates
9300K
6500K/sRGB
sRGB
As defined in 3.3, 1366*768
non-interlaced mode (1366*768@60Hz 85.5MHz), signal sources must have
75 ohm output impedance
controls to be set to 300 nits with full screen 100 % duty cycle white signal
More than 30 minutes after power on with signal supplied.
400 -- 600 lux
20 ± 5 C
B_min
B_max
ABS (YA - YB)
(x,y)
x = 0.283 ± 0.02
y = 0.297 ± 0.02
x = 0.313 ± 0.02
y = 0.329 ± 0.02
x = 0.313 ± 0.02
y = 0.329 ± 0.02
X 100% > 75% (Follow panel spec)
X 100%
<
YA
PerfectuneII
PerfectuneII
PerfectuneII
Meridian 1
1.5 %
77
Table of Contents