  • Page 3 Install, test and maintain the module according to these instructions, NFPA codes, local codes, and the authority having jurisdiction (AHJ). Failure to follow these instructions can result in failure of a detector to initiate an alarm event. Bosch Security Systems, Inc. is not responsible for improperly installed, tested or maintained devices.
  • Page 4 Bosch does not recommend using the module to power devices that are sensitive to excessive ripple. A 16.5 V, 40 VA transformer (D1640, supplied with the D8132) is required to power the module. A green LED on the module lights to indicate the presence of AC power.
  • Page 5: Installation

    12 V, 13.5 Ah batteries will be installed. Fasten the module in place with the three mounting screws provided. The green AC power LED on the module can be viewed if a knock-out is removed on the front door of the enclosure. Bosch Security Systems, Inc. Installation manual 2018.05 | 4.0 | F.01U.036.305...
  • Page 6 Figure 4.1: Wiring for extended battery standby time and providing additional auxiliary current output 1 AC circuit common to both 2 Transformers* transformers 3 Control panel 4 D122 Dual battery harness 2018.05 | 4.0 | F.01U.036.305 Installation manual Bosch Security Systems, Inc.
  • Page 7 * GV3 and GV4 panels require a D1640 transformer. For legacy products refer to the control panel documentation. ** The D8132 can support up to 27 Ah of backup battery. If two batteries are used they must have the same Ampere-hour (Ah) rating.
  • Page 8 | Wiring Battery charger modules Notice! The D8132 Module is not UL Listed for “standalone” operation, and cannot be used in this configuration for UL applications. To determine the appropriate batteries for use with the module, see the table which displays...
  • Page 9 * GV3 and GV4 panels require a D1640 transformer. For legacy products refer to the control panel documentation. ** The D8132 can support up to 27 Ah of battery backup. If two batteries are used, they must have the same Ampere-hour (Ah) rating.
  • Page 10: Troubleshooting

    16.5 VAC, 40 VA supplied by D1640 plug‑in transformer Supplied Current 1.2 A Ampere-hours 27 Ah maximum measured with batteries in circuit Mechanical Dimensions (HxWxD) 0.75 in. x 3.0 in. x 5.0 in. (1.9 cm x 7.6 cm x 12 cm) 2018.05 | 4.0 | F.01U.036.305 Installation manual Bosch Security Systems, Inc.