Honeywell FlexGuard FG-1625F Installation Instructions

Glassbreak detector
Hide thumbs Also See for FlexGuard FG-1625F:

Quick Links

FlexGuard
Refer to Supplemental Information (next page) for complete descriptions of these installation steps
FG-1625F Glassbreak Detector
INSERT BLADE
AND TWIST
M AX
S1 =
SE NS
S2 =
1
SE NS
2
M ED
S1 =
S2 =
SE NS
SE NS
1
2
LO W
TE S
T
S1 =
SE NS
PA D
S2 =
1
S
SE NS
2
LO W
ES T
S E N
S 1
S E N
S 2
LA TC
S1 =
H
S2 =
SE NS
SE NS
1
LC D
2
Opening FG-1625F Case
Test Mode Pads
MA X
S1 =
SE NS
S2 =
1
SE NS
2
ME D
S1 =
SE NS
S2 =
1
SE NS
2
LO W
T E S
S1 =
T
SE NS
P A D
S2 =
1
SE NS
S
LO W
2
ES T
S E N
S 1
S E N
S 2
L A T
S1 =
SE NS
C H
S2 =
1
SE NS
L E D
2
FG-1625F Glassbreak Detector, Front View
Mounting Hole
TMPR
TMPR
C
Terminal Block
NC
V -
V +
Wire Restraint
WIRE RESTRAINT
Mounting Hole
FG1625F-3
FG-1625F Glassbreak Detector, Back View
Select Mounting Location
Wall Mount
(Top View)
Ceiling Mount: (Side View)
Test Location w/ 9V Battery
If uncertain about location or range, test the detector
before mounting using a 9V battery as shown:
5-051-737-00 Rev C
®
FG-1625F Glassbreak Detector Installation Instructions
'8
Set Sensitivity & LED Configuration
SENS 1
SENS 2
LATCH
LED
FG1625F-7
FG1625F-1
SENS1 & SENS2 configure sensitivity
SENSITIVITY
MAX
MEDIUM
Mounting Hole
LOW
LOWEST
Microphone
NOTE: Ranges are approximate and vary with each
room's acoustic properties. Always verify range with an
DIP Switch
IntelliSense FG-701 Glassbreak Simulator.
LED Indicators
The LATCH and LED DIP switches configure LED
indicator behavior.
Mounting Hole
SWITCH
LATCH
Red LED lights for 5
seconds during alarm
LEDs disabled (except for
LED
FG1625F-2
power up and test mode
1
The timing of the alarm relay is not affected by the latched Alarm LED.
2
Reset the Alarm LED by removing/restoring power, or by toggling the
detector in and out of Test Mode.
3
LEDs can be enabled/disabled using FG-701.
Connect Detector
Connect detector using 18 to 22 AWG wire, with ends
stripped approximately 6mm (1/4 in.) Use the
appropriate wiring method as shown in these diagrams:
Tamper Loop (NC)
Normally Closed Loop
Control Panel Power
1625F-8
Normally Closed Loop/No EOL Resistor
Tamper Loop w/
EOL resistor
Normally Closed
Loop w/
EOL Resistor
Control Panel Power
1625F-9
Normally Closed Loop/With EOL Resistor
Install Detector
Test location and set Sensitivity as needed.
FG1625F-5
Mount the junction box as appropriate.
When wiring the detector, be sure to tie-wrap
the wires to the wire restraint loop on back of
the device (as shown below).
8
8 +
FG1625F-6
MAX
S1
S2
S1 = SENS1
S2 = SENS2
MED
S1
S2
S1 = SENS1
S2 = SENS2
LOW
TEST
PADS
S1
S2
SENS 1
S1 = SENS1
S2 = SENS2
SENS 2
LOWEST
LATCH
LED
S1
S2
S1 = SENS1
S2 = SENS2
APPROXIMATE
SENS1
SENS2
RANGE
7.6m (25 ft)
OFF
OFF
4.6m (15 ft)
ON
OFF
3m (10 ft)
OFF
ON
1.5m (5 ft)
ON
ON
OFF
ON
Red LED latches ON when
1, 2
detector goes into alarm
LEDs always enabled
3
)
TMPR
TMPR
C
NC
V+
TMPR
TMPR
C
NC
V+
Page 1
Mount the detector to the junction box using
the appropriate screws (not supplied).
P R
T M
P R
T M
C
N C
-
V
+
V
IN T
E S TR A
W IR E R
Use Tie Wrap to attach wires to Wire Restraint
Wiring Detector/Wire Restraint Loop
M A
X
S1 =
S2 =
SE NS
1
SE NS
2
M ED
S1 =
S2 =
SE NS
SE NS
1
2
LO W
T E S
T
S1 =
SE NS
P A D
S2 =
1
S
SE NS
2
LO W
S E N
ES T
S 1
S E N
S 2
L A T
S1 =
C H
S2 =
SE NS
SE NS
1
L E D
2
Attaching Detector to Junction Box
Test Detector Installation
Enter Test Mode using FG-701 (see Testing the
Detector on the next page) or manually by shorting
Test Mode pads (as below). Replace cover before
testing the detector.
TEST
MAX
TEST
S1
S2
S1 = SENS1
S2 = SENS2
PADS
MED
S1
S2
S1 = SENS1
S2 = SENS2
SENS 1
LOW
TEST
PADS
S1
SENS 2
S2
S1 = SENS1
SENS 1
S2 = SENS2
SENS 2
LOWEST
LATCH
S1
S2
S1 = SENS1
LED
S2 = SENS2
Install Cover
Replace the cover as shown below.
M AX
S1 =
SE NS
S2 =
SE NS
1
2
M ED
S1 =
SE NS
S2 =
1
SE NS
2
LO W
T E S
T
S1 =
P A D
S2 =
SE NS
1
S
SE NS
2
LO W
ES T
S E N
S 1
S E N
S 2
LA T
S1 =
C H
S2 =
SE NS
SE NS
1
LE D
2
FG1625F-11
LATCH
LED
FG1625F-13
loading

Summary of Contents for Honeywell FlexGuard FG-1625F

  • Page 1 ® FlexGuard FG-1625F Glassbreak Detector Installation Instructions Refer to Supplemental Information (next page) for complete descriptions of these installation steps • FG-1625F Glassbreak Detector Mount the detector to the junction box using the appropriate screws (not supplied). INSERT BLADE AND TWIST FG1625F-6 Set Sensitivity &...
  • Page 2 The following table summarizes The user is cautioned that changes or modifications not expressly the LED messages. approved by Honeywell could void the user’s authority to operate this 6. Preparing Mounting Location equipment. The FG-1625F is designed for flush mounting using a...