TM
SiX
Series
The SiXGB is a wireless glassbreak detector intended for use with Honeywell controls that support SiX™ Series
devices.
Mounting Guidelines
The SiXGB can be mounted on the
wall or on the ceiling:
• within 7.6 m (25 feet) of the
protected glass
• within clear view of the protected
glass
• at least 2 m (6.5 feet) from the floor
• at least 1 m (3.3 feet) from forced
air ducts
• at least 1 m (3.3 feet) from sirens or
bells greater than 5 cm (2 inches) in
diameter
• between the protected glass and
any heavy window coverings
• when heavy window coverings are
present, the detector can be
mounted on the window frame
• Avoid mounting the detector on the
same wall as the protected glass,
on free-standing posts or pillars, or
in rooms with noisy equipment (air
compressors, bells, power tools,
etc.), if this equipment is operated
when the detector is armed.
To remove the mounting bracket:
Turn the top of the detector 15 degrees counter-
clockwise and separate the mounting bracket.
NOTE: Before mounting the device permanently,
conduct Go/No Go tests (see controller's
instructions) to verify adequate signal strength and
adjust the device location and orientation as
necessary.
The rear tamper plate MUST be mounted to a stud,
solid wood, or with a robust wall anchor.
SiXGB
W all Mount ( To pView)
Do NOT mo unt o n
c o lumns, po sts o r po le s.
Installation Instructions
< 7.6m (25')
Ceiling
Glass
Glass
Ceiling Mount ( Side View)
Flo o r
3.5 mm x 25 mm
(#6 x 1")
3.5 mm x 25 mm
(#6 x 1")
> 1m
(3.3')
> 1m
(3.3')
> 2.0m (6.5')
> 5 cm
(2") Diameter
Optimal
Satisfactory
No
RF6GB-Ceiling Mo unt
[2]
[1]