Sony DCU-8000 Installation Manual

Sony DCU-8000 Installation Manual

Mks-8700 series. device control unit pack. device control unit
Hide thumbs Also See for DCU-8000:
DEVICE CONTROL UNIT PACK
DCU-8000
DEVICE CONTROL UNIT
MKS-8700
HK-PSU03
MKS-8701
MKS-8702
INSTALLATION MANUAL
1st Edition
Table of Contents
loading

Summary of Contents for Sony DCU-8000

  • Page 1 DEVICE CONTROL UNIT PACK DCU-8000 DEVICE CONTROL UNIT MKS-8700 HK-PSU03 MKS-8701 MKS-8702 INSTALLATION MANUAL 1st Edition...
  • Page 2 à moins d'être qualifié pour en effectuer d'autres. Pour toute réparation faire appel à une personne compétente uniquement. MKS-8700 Serial No. 10001 and Higher HK-PSU03 Serial No. 10001 and Higher MKS-8701 Serial No. 10001 and Higher MKS-8702 Serial No. 10001 and Higher DCU-8000 IM...
  • Page 3 10 cm (4 inches) or more away from walls in order to obtain proper exhaust and radiation of heat. When using a LAN cable: For safety,do not connect to the connector for peripheral device wiring that might have excessive voltage. 1 (P) DCU-8000 IM...
  • Page 5: Table Of Contents

    Checks on Completion of Installation ............1-16 1-8-1. Description of On-board Switches and LEDs ......1-16 1-9. System Connection ..................1-22 2. Service Overview 2-1. Troubleshooting ..................2-1 2-2. Periodic Inspection and Maintenance ............2-3 2-2-1. Cleaning ..................2-3 DCU-8000 IM...
  • Page 7: Manual Structure

    Manual Structure Purpose of this manual This manual is the installation manual of Device Control Unit Pack DCU-8000 and the optional boards and units. This manual is intended for use by trained system and service engineers, and describes the information on installing the DCU-8000.
  • Page 9: Installation

    . Areas subject to static electricity. Ventilation For customers in the all Europian countories The inside of the DCU-8000 is cooled by a fan (both sides 1 Power cord, 250 V 10 A (2.4 m) : ! 1-782-929-21 on the rear).
  • Page 10: Installation Space (External Dimensions)

    1-3. Installation Space (External dimensions) 1-3. Installation Space (External dimensions) Rack mount metal (supplied with RMM-10) 132.4 17.5 Unit : mm DCU-8000 IM...
  • Page 11: Installing The Options

    1-4. Installing the Options 1-4. Installing the Options The DCU-8000 is shipped from the factory with the necessary options (refer to the following table) already installed in the MKS-8700, in accordance with the specified system configuration. DCU-8000 Options Model name...
  • Page 12: Installing The Plug-In Boards

    Screws (with drop-safe) Eject levers Plug-in board Name of option Name of board Slot on the front side MKS-8701 RC-90 2, 3, 4, 5, 6 MKS-8702 IF-848 2, 3, 4, 5, 6 DCU-8000 IM...
  • Page 13: Installing The Connector Board

    RC-90 board that is inserted in the slot in the front. MKS-8702 CN-2194 Install the board into the slot in the rear that corresponds to the IF-848 board that is inserted in the slot in the front. DCU-8000 IM...
  • Page 14: Installing The Hk-Psu03

    Remove the blank panel. B3 x 5 Blank panel Store the removed blank panel in a safe location. 3. Install the HK-PSU03 firmly as far as it will go. 4. Secure the HK-PSU03 with the two screws. B3 x 5 HK-PSU03 DCU-8000 IM...
  • Page 15: Rack Mounting

    This section describes the rack mounting procedure using The DCU-8000 installs in a 19-inch standard rack. the RMM-10 rack mount kit. To mount the DCU-8000 in a rack, use the specified rack mount kit and follow the procedure described below. Tighten the screws to the following torque.
  • Page 16 5. Align the groove of the rack tool at the side of the equipment with the rail, and slide the equipment to the 8. Attach the front panel to the equipment. rear. The rack tools are hooked on the rails as shown below. Rack tool Rack tool Rail Rail DCU-8000 IM...
  • Page 17: Matching Connectors And Cables

    1-6. Matching Connectors and Cables Use the following connectors, cables or equivalents when connecting cables to the unit. Model name Panel indication Connector name Matching connector and cable Name Sony part No. MKS-8700 TALLY/GPI IN 1-34, D-sub 37-pin, Female D-sub 37-pin, Male 35-68, 69-102...
  • Page 18: Input/Output Signals Of Connectors

    TALLY/GPI IN 22 Received data (+) TALLY/GPI IN 24 No Connection TALLY/GPI IN 26 No Connection TALLY/GPI IN 28 Received data (_) TALLY/GPI IN 30 No Connection TALLY/GPI IN 32 No Connection TALLY/GPI IN 34 (*2) Ground 1-10 DCU-8000 IM...
  • Page 19 TALLY/GPI IN 92 TALLY/GPI IN 60 TALLY/GPI IN 94 TALLY/GPI IN 62 TALLY/GPI IN 96 TALLY/GPI IN 64 TALLY/GPI IN 98 TALLY/GPI IN 66 TALLY/GPI IN 100 TALLY/GPI IN 68 (*2) TALLY/GPI IN 102 (*2) Ground Ground 1-11 DCU-8000 IM...
  • Page 20: Mks-8701

    TALLY/GPI OUT 17A TALLY/GPI OUT 18A Ground TALLY/GPI OUT 1B Tally/GPI outputs TALLY/GPI OUT 2B TALLY/GPI OUT 3B TALLY/GPI OUT 4B TALLY/GPI OUT 5B TALLY/GPI OUT 6B TALLY/GPI OUT 7B TALLY/GPI OUT 8B TALLY/GPI OUT 9B TALLY/GPI OUT 10B 1-12 DCU-8000 IM...
  • Page 21 TALLY/GPI OUT 35A TALLY/GPI OUT 36A Ground TALLY/GPI OUT 19B Tally/GPI outputs TALLY/GPI OUT 20B TALLY/GPI OUT 21B TALLY/GPI OUT 22B TALLY/GPI OUT 23B TALLY/GPI OUT 24B TALLY/GPI OUT 25B TALLY/GPI OUT 26B TALLY/GPI OUT 27B TALLY/GPI OUT 28B 1-13 DCU-8000 IM...
  • Page 22 TALLY/GPI OUT 53A TALLY/GPI OUT 54A Ground TALLY/GPI OUT 37B Tally/GPI outputs TALLY/GPI OUT 38B TALLY/GPI OUT 39B TALLY/GPI OUT 40B TALLY/GPI OUT 41B TALLY/GPI OUT 42B TALLY/GPI OUT 43B TALLY/GPI OUT 44B TALLY/GPI OUT 45B TALLY/GPI OUT 46B 1-14 DCU-8000 IM...
  • Page 23: Mks-8702

    REMOTE1 to 6 : RS-422A (D-sub 9-pin, Female) to External Device _ EXT VIEW _ Pin No. Signal Name Function Frame ground Received data (_) Transmitted data (+) Common ground No Connection Common ground Received data (+) Transmitted data (_) No Connection 1-15 DCU-8000 IM...
  • Page 24: Checks On Completion Of Installation

    Not lit when the REF signal is not input. Lit when the REF signal is input via the REF IN connector. D755 (D-15) : 100 LAN (IC151/CA-47 board) status indication Lit while communication with the main panel is in progress at 100 Mb/s. 1-16 DCU-8000 IM...
  • Page 25 +5 V power supply status indication. Lit when the +5 V power is supplied. S752 (G-15) : System reset switch Reset switch for the entire DCU-8000. D767 (D-15) : + + + + + 12 V +12 V power supply status indication.
  • Page 26 DI4 (green) (B-5) : + + + + + 3.3 V Indicates the status of the VCC (CORE) and VCC (I/O) power supplied to the CPU-DK module. Lit while the specified powers are turned on. 1-18 DCU-8000 IM...
  • Page 27 Serial I/F (IC402/IF-848 board) status indication. Flashing : When the memory has an abnormality Not lit : During normal operation Lit : When the system does not start up correctly Flashing : When the memory has an abnormality 1-19 DCU-8000 IM...
  • Page 28 D870 (E-15) : IF CPU status LED board”. IF CPU status indication. Used only for production in the assembly factory. (K-5) Refer to of “1. CA-47 board”. 1-20 DCU-8000 IM...
  • Page 29 Lit when the +3.3 V power is supplied. D104 (B-4) : + + + + + 12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown. 1-21 DCU-8000 IM...
  • Page 30: System Connection

    However, a single Ethernet switch can be used for connecting each LAN. For information about Ethernet switches that can be used in an MVS system, contact your local Sony Sales Office/Service Center. For detailed information about setting up the Ethernet switch, refer to the documentation supplied with the switch.
  • Page 31: Service Overview

    2-1. Troubleshooting The main power cannot be turned on. (Indicator does not light green.) Flow1 The main power of the DCU-8000 cannot be turned on. (Indicator does not light green.) Is the POWER switch of the DCU -8000 turned ON? Set it to ON.
  • Page 32 Is the center control panel side already set? Set it. The CA-47 board of the MKS-8700, or the IF-848 board or the CN-2194 board of the MKS-8702 that is inserted in the corresponding slot of the MKS-8700 is probably defective. DCU-8000 IM...
  • Page 33: Periodic Inspection And Maintenance

    Front panl Filter 2. Fan The inside of the DCU-8000 is cooled by a fan (both sides on the rear). If dust has accumulated in the intake of the fan, air is prevented from flowing smoothly and this may result in a temperature rise inside the machine.
  • Page 35 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 36 Printed in Japan Sony Corporation DCU-8000 (SY) E 2001. 10 16 B&P Company 3-206-023-01 (1) ©2001...