KERN EOA 10K-3 Operating Manual

Eoa series platform balances
Hide thumbs Also See for EOA 10K-3:

Quick Links

Návod na obsluhu(EN)
Balíková váha
KERN EOA(SK)
Version 1.0
10/2013
GB
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
Phone: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
EOA-BA-e-1310
Table of Contents
loading

Summary of Contents for KERN EOA 10K-3

  • Page 1 KERN & Sohn GmbH Ziegelei 1 Phone: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: [email protected] Internet: www.kern-sohn.com Návod na obsluhu(EN) Balíková váha KERN EOA(SK) Version 1.0 10/2013 EOA-BA-e-1310...
  • Page 2: Table Of Contents

    KERN EOA Version 1.0 10/2013 Operating manual Platform balances Contents Technical data....................3 Declaration of conformity ................5 Basic Information (General)................6 Proper use........................ 6 Improper Use ......................6 Warranty ........................6 Monitoring of Test Resources ................7 Basic Safety Precautions ................7 Pay attention to the instructions in the Operation Manual ........
  • Page 3: Technical Data

    1 Technical data KERN EOA 10K-3 EOA 30K-2 Readability (d) 0.005 kg 0.01 kg Weighing range (max) 15 kg 35 kg Reproducibility 0.005 kg 0.01 kg Linearity ± 0.025 kg ± 0.05 kg Warm-up time 10 minutes Weighing Units Recommended adjustment weight,...
  • Page 4 KERN EOA 50K-2 EOA 100K-2 Readability (d) 0.02 kg 0.05 kg Weighing range (max) 60 kg 150 kg Reproducibility 0.02 kg 0.05 kg Linearity ± 0.1 kg ± 0.25 kg Warm-up time 10 minutes Weighing Units Recommended adjustment weight, 40 kg...
  • Page 5: Declaration Of Conformity

    EN 60950-1: 2006+A11: 2009 23.09.2013 Datum Signatur Date Signature Ort der Ausstellung 72336 Balingen Albert Sauter Place of issue KERN & Sohn GmbH Geschäftsführer Managing director KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: [email protected], Internet: www.kern-sohn.com EOA-BA-e-1310...
  • Page 6: Basic Information (General)

    The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. 3.3 Warranty Warranty claims shall be voided in case...
  • Page 7: Monitoring Of Test Resources

    In KERN's accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost. 4 Basic Safety Precautions 4.1 Pay attention to the instructions in the Operation Manual...
  • Page 8: Unpacking, Setup And Commissioning

    6 Unpacking, Setup and Commissioning 6.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance. Therefore, observe the following for the installation site: Place the balance on a firm, level surface;...
  • Page 9: Scope Of Delivery

    6.4 Mains connection (optional) Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters. Using other makes requires consent by KERN. 6.5 Initial Commissioning In order to obtain exact results with the electronic balances, your balance must have reached the operating temperature (see warming up time chap.
  • Page 10: Adjustment

    6.6 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated - in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location (only if the balance has not already been adjusted to the location in the factory).
  • Page 11: Operation

    7 Operation 7.1 Keyboard overview Button Description Function Switch on-off balance ON/OFF button  short pressing: Tare balance TARE button  long pressing: Invoke adjustment EOA-BA-e-1310...
  • Page 12: Weighing

    7.2 Weighing Operation Display  Start balance by pressing  Await zero display  Place goods onto weighing plate. Now the weight is displayed, after the standstill control appears the weighing unit [kg] right-hand in the display. (example) If the material to be weighed is heavier than the weighing range, the display will show [E] (=Overload).
  • Page 13: Plus/Minus Weighing

    7.4 Plus/minus weighing Operation Display  Turn on weighing scale and wait for zero to be displayed.  Put the nominal weight on the weighing plate and tare (example) to [0] using the button.   Remove the nominal weight. The nominal weight appears as negative display.
  • Page 14: Servicing, Maintenance, Disposal

    Spilled weighing goods must be removed immediately. 8.2 Servicing, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. Before opening, disconnect from power supply. 8.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
  • Page 15: Instant Help

    9 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process must then be restarted from the beginning. Help: Fault Possible cause The displayed weight does not glow. The balance is not switched on.