4. Choose Predefined if you like to view a basic selection of registers.
Choose the All option if you want to select a certain range of registers by your own choice. You can
specify a start value in the Start Register input field, and the total number of registers to be displayed
in the Number of Registers field (1-500). Up to 50 registers is recommended for a quick update of the
list
5. Click the Read button to update the View Input/Holding Registers window with fresh device data.
For information on how to view database registers in AMS, see
page
6.2.2

Editing holding registers

Most Holding Registers can be edited simply by typing a new value in the appropriate Value input field.
Some Holding Registers (marked grey in the Value column) can be edited in a separate window. In this
case you can choose from a list of options or you can change separate data bits.
For more information see the
1,
Note that Input Register data from the Rosemount
Hub. The Input Registers presented in TankMaster WinSetup refer to the internal register area of the Rosemount 2410. Therefore, for tank 1 you will have
to add 10000 to the Rosemount 2240S internal register number as given by
(requires a Rosemount 2410 with the multi-tank option) you will have to add 12000, for tank 3 you will have to add 14000, and so on.
Service and Troubleshooting
(1)
.
138.
2240S transmitter is temporarily stored in the Input Register database of the Rosemount 2410 Tank
RosemountTank Gauging System Configuration
Table 6-4
in order to find the register presented by WinSetup. For tank 2
Service and Troubleshooting
"Viewing input and holding registers" on
Manual.
October 2017
109