GE D30D00HCHF8AH6AM6BP8BX7A Instruction Manual page 500

Ur series line distance protection system
Table of Contents
B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 18 of 58)
ADDR
REGISTER NAME
4114
PRT1 GOOSE Enabled
4115
PRT2 GOOSE Enabled
4116
PRT3 GOOSE Enabled
4117
IEC Communications Reserved (39 items)
413E
High Enet Traffic Function
413F
High Enet Traffic Events
4140
DNP Object 1 Default Variation
4141
DNP Object 2 Default Variation
4142
DNP Object 20 Default Variation
4143
DNP Object 21 Default Variation
B
4144
DNP Object 22 Default Variation
4145
DNP Object 23 Default Variation
4146
DNP Object 30 Default Variation
4147
DNP Object 32 Default Variation
Ethernet Switch (Read/Write Setting)
4148
Ethernet Switch IP Address
414A
Ethernet Switch Modbus IP Port Number
414B
Ethernet Switch Port 1 Events
414C
Ethernet Switch Port 2 Events
414D
Ethernet Switch Port 3 Events
414E
Ethernet Switch Port 4 Events
414F
Ethernet Switch Port 5 Events
4150
Ethernet Switch Port 6 Events
Ethernet Switch Actual Values (Read Only)
4151
Ethernet Switch MAC Address
4154
Ethernet Switch Port 1 Status
4155
Ethernet Switch Port 2 Status
4156
Ethernet Switch Port 3 Status
4157
Ethernet Switch Port 4 Status
4158
Ethernet Switch Port 5 Status
4159
Ethernet Switch Port 6 Status
415A
Switch Firmware Version
Communications Actual Values (Read Only)
4160
Modbus Available TCP/IP Connections
4161
DNP Available TCP/IP Connections
4162
IEC Available TCP/IP Connections
4163
MMS Available TCP/IP Connections
4164
PMU Available TCP/IP Connections
Simple Network Time Protocol (Read/Write Setting)
4168
Simple Network Time Protocol (SNTP) Function
4169
Simple Network Time Protocol (SNTP) Server IP Address
416B
Simple Network Time Protocol (SNTP) UDP Port Number
Clock (Read/Write Setting)
419F
Synchronizing Source
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
Clock (Read/Write Setting)
41A2
SR Date Format
41A4
SR Time Format
41A6
IRIG-B Signal Type
41A7
Clock Events Enable / Disable
41A8
Time Zone Offset from UTC
41A9
Daylight Savings Time (DST) Function
41AA
Daylight Savings Time (DST) Start Month
B-26
RANGE
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 2
1 to 3
0 to 3
0 to 3
0 to 3
0 to 3
1 to 5
0 to 5
0 to 4294967295
1 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
---
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0.00 to 99.99
0 to 4
0 to 2
0 to 2
0 to 5
0 to 4
0 to 1
0 to 4294967295
1 to 65535
0 to 3
0 to 235959
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
–24 to 24
0 to 1
0 to 11
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F102
---
1
F102
---
1
F001
---
1
F102
---
1
F102
---
1
F001
---
1
F001
---
1
F523
---
1
F524
---
1
F523
---
1
F523
---
1
F001
---
1
F525
---
1
F003
---
1
F001
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
---
F072
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
0.01
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F003
---
1
F001
---
1
F623
---
1
F050
---
1
F051
---
1
F052
---
1
F114
---
1
F102
hours
0.5
F002
---
1
F102
---
1
F237
DEFAULT
1 (Enabled)
1 (Enabled)
1 (Enabled)
0
0 (Disabled)
0 (Disabled)
2
2
0 (1)
0 (1)
0 (1)
0 (1)
1
0 (1)
3232235778
502
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0 (Fail)
0
4
2
2
5
4
0 (Disabled)
0
123
0 (None)
0
0
0
0 (None)
0 (Disabled)
0
0 (Disabled)
0 (January)
GE Multilin
Table of Contents
loading

This manual is also suitable for:

D30