Allen-Bradley 1756-IB16K Installation Instructions Manual

Allen-Bradley 1756-IB16K Installation Instructions Manual

Controllogix dc digital i/o modules
Installation Instructions
Original Instructions
ControlLogix DC Digital I/O Modules
Catalog Numbers 1756-IB16, 1756-IB16K, 1756-IB16D, 1756-IB16DK, 1756-IB16I, 1756-IB16IK, 1756-IB16IF, 1756-IB16IFK,
1756-IB16ISOE, 1756-IB16ISOEK, 1756-IB32, 1756-IB32K, 1756-IC16, 1756-IG16, 1756-IN16, 1756-IV16, 1756-IV16K, 1756-IV32,
1756-IV32K, 1756-LSC8XIB8I, 1756-LSC8XIB8IK, 1756-OB8, 1756-OB8EI, 1756-OB16D, 1756-OB16DK, 1756-OB16E, 1756-OB16EK,
1756-OB16I, 1756-OB16IEF, 1756-OB16IEFK, 1756-OB16IEFS, 1756-OB16IS, 1756-OB32, 1756-OB32K, 1756-OC8, 1756-OG16,
1756-ON8, 1756-OV16E, 1756-OV32E
Topic
ControlLogix® digital I/O modules are input and output modules that provide On/Off detection and actuation. By using the producer/consumer
network model, digital I/O modules can produce information when needed while providing additional system functions.
Page
5
5
5
5
6
6
7
7
10
Table of Contents
loading

Summary of Contents for Allen-Bradley 1756-IB16K

  • Page 1: Table Of Contents

    Installation Instructions Original Instructions ControlLogix DC Digital I/O Modules Catalog Numbers 1756-IB16, 1756-IB16K, 1756-IB16D, 1756-IB16DK, 1756-IB16I, 1756-IB16IK, 1756-IB16IF, 1756-IB16IFK, 1756-IB16ISOE, 1756-IB16ISOEK, 1756-IB32, 1756-IB32K, 1756-IC16, 1756-IG16, 1756-IN16, 1756-IV16, 1756-IV16K, 1756-IV32, 1756-IV32K, 1756-LSC8XIB8I, 1756-LSC8XIB8IK, 1756-OB8, 1756-OB8EI, 1756-OB16D, 1756-OB16DK, 1756-OB16E, 1756-OB16EK, 1756-OB16I, 1756-OB16IEF, 1756-OB16IEFK, 1756-OB16IEFS, 1756-OB16IS, 1756-OB32, 1756-OB32K, 1756-OC8, 1756-OG16,...
  • Page 2 ControlLogix DC Digital I/O Modules ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice.
  • Page 3 ControlLogix DC Digital I/O Modules Prevent Electrostatic Discharge ATTENTION: Before installing, configuring, operating, or maintaining this product, read this document and the documents ATTENTION: This equipment is sensitive to electrostatic listed in the additional resources section for installing, discharge, which can cause internal damage and affect normal configuring, or operating equipment.
  • Page 4 ControlLogix DC Digital I/O Modules North American Hazardous Location Approval The following information applies when operating this equipment in hazardous Informations sur l'utilisation de cet équipement en environnements dangereux. locations. Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en Products marked "CL I, DIV 2, GP A, B, C, D"...
  • Page 5: Installation Requirements

    ControlLogix DC Digital I/O Modules Slide the module into the slot in the chassis until the locking tabs click. WARNING: Special Conditions for Safe Use: • This equipment is not resistant to sunlight or other sources of UV radiation Locking Tab •...
  • Page 6: Assemble The Rtb And The Housing

    ControlLogix DC Digital I/O Modules 2. Slide the RTB into the housing until it snaps into place. ATTENTION: When using catalog numbe1756-TBNH, do not wire more than two 0.33…1.3 mm (22…16 AWG) conductors on any terminal. Use only the same size wires with no intermixing of solid and stranded wire types.
  • Page 7: Removable Terminal Blocks (Rtb) Ratings

    Do not wire multiple conductors on any terminal. housing 1756-OB16IS 36 pin 1756-OB32, 1756-OB32K 1756-OV32E Extended-depth 1756-TBE terminal block housing Specifications Specifications: 1756-IB16, 1756-IB16K, 1756-IB16D, 1756-IB16DK, 1756-IB16I, 1756-IB16IK, 1756-IB16IF, 1756-IB16IFK, 1756-IB16ISOE, 1756-IB16ISOEK, 1756-IB32, 1756-IB32K 1756-IB16, 1756-IB16D, 1756-IB16I, 1756-IB16IF, 1756-IB16ISOE, 1756-IB32, Attribute 1756-IB16K 1756-IB16DK...
  • Page 8 ControlLogix DC Digital I/O Modules Specifications: 1756-IC16, 1756-IG16, 1756-IN16, 1756-IV16, 1756-IV16K, 1756-IV32, 1756-IV32K, 1756-LSC8XIB8I, 1756-LSC8XIB8IK 1756-IV16, 1756-IV32, 1756-LSC8XIB8I, Attribute 1756-IC16 1756-IG16 1756-IN16 1756-IV16K 1756-IV32K 1756-LSC8XIB8IK Backplane: 5.1V DC, Backplane: 5.1V DC, Backplane: 5.1V DC, Backplane: 5.1V DC, 140 mA, 24V DC, 2 mA 135 mA, 24V DC, 3 mA Backplane: 5.1V DC, Backplane: 5.1V DC,...
  • Page 9 ControlLogix DC Digital I/O Modules Specifications: 1756-OB16IEFS, 1756-OB16IS, 1756-OB32, 1756-OB32K, 1756-OC8, 1756-OG16, 1756-ON8 1756-OB32, Attribute 1756-OB16IEFS 1756-OB16IS 1756-OC8 1756-OG16 1756-ON8 1756-OB32K Backplane: 5.1V DC, 300 mA, 24V DC, 2 mA Backplane: 5.1V DC, Backplane: 5.1V DC, Backplane: 5.1V DC, Output: 10…31.2V DC, 320 mA, 24V DC, 3 mA Backplane: 5.1V DC, Backplane: 5.1V DC,...
  • Page 10: Additional Resources

    Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Automation, Rockwell Software, and ControlLogix are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400...

Table of Contents