Mitsubishi Electric FX3UC-16MT/DSS Hardware Manual

Melsec-f fx3uc (d, ds, dss) series

Quick Links

Side
B
Side
Side
A
B
JAPANESE
ENGLISH
FX
(D, DS, DSS) SERIES
3UC
PROGRAMMABLE CONTROLLERS
HARDWARE MANUAL
Manual Number
JY997D50501
Revision
E
Date
December 2017
This manual describes the part names, dimensions, mounting,
cabling and specifications for the product. This manual is extracted
from FX
(D,DS,DSS) Series User's Manual - Hardware Edition.
3UC
Refer to FX
Series User's Manual - Hardware Edition details.
3UC
Before use, read this manual and manuals of relevant products fully
to acquire proficiency in the handling and operating the product.
Make sure to learn all the product information, safety information,
and precautions.
And, store this manual in a safe place so that it can be taken out and
read whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this
manual are the registered trademarks or trademarks of each
company.
Effective December 2017
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by
may also cause severe injury.
It is important to follow all precautions for personal safety.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
• Before cleaning or retightening terminals, cut off all phases of
the power supply externally.
Failure to do so may cause electric shock.
JY997D50501E
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Before modifying or disrupting the program in operation or
running the PLC, carefully read through this manual and the
associated manuals and ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
• Do not change the program in the PLC from two or more
peripheral equipment devices at the same time. (i.e. from a
programming tool and a GOT)
Doing so may cause destruction or malfunction of the PLC program.
• Use the battery for memory backup correctly in FX
Series
3UC
User's Manual - Hardware Edition.
- Use the battery only for the specified purpose.
- Connect the battery correctly.
- Do not charge, disassemble, heat, put in fire, short-circuit,
connect reversely, weld, swallow or burn the battery, or apply
excessive forces (vibration, impact, drop, etc.) to the battery.
- Do not store or use the battery at high temperatures or
expose to direct sunlight.
- Do not expose to water, bring near fire or touch liquid
leakage or other contents directly.
- Incorrect handling of the battery may cause heat excessive
generation, bursting, ignition, liquid leakage or deformation,
and lead to injury, fire or failures and malfunctions of facilities
and other equipment.
- When replacing the battery, make sure to use our specified
product (FX
-32BL).
3U
- When a battery error occurs ("BAT" LED is lit in red), follow the
description in FX
Series User's Manual - Hardware Edition.
3UC
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the
memory cassette. If the memory cassette is attached or
detached while the PLC's power is on, the data in the memory
may be destroyed, or the memory cassette may be damaged.
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.
• Turn off the power to the PLC before connecting or
disconnecting any extension cable.
Failure to do so may cause equipment failures or malfunctions.
• Turn off the power to the PLC before attaching or detaching the
following devices.
Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, extension units/blocks, connector
conversion adapter, extension power supply units, special
adapters, and FX Series terminal blocks.
- Battery and memory cassettes
• Do not use the chemicals for cleaning.
• If there is the possibility of touching the PLC inside a control
panel in maintenance, make sure to discharge to avoid the
influence of static electricity.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for
the environmentally safe recycling and disposal of your device.
When disposing of batteries, separate them from other waste
according to local regulations.
(For details of the Battery Directive in EU countries, refer to
FX
Series User's Manual - Hardware Edition.)
3UC
TRANSPORTATION
AND STORAGE
PRECAUTIONS
• Before transporting the PLC, turn on the power to the PLC to
check that the BAT LED is off, and check the battery life.
If the PLC is transported with the BAT LED on or the battery
exhausted, the battery-backed data may be unstable during
transportation.
TRANSPORTATION
AND STORAGE
PRECAUTIONS
• The PLC is a precision instrument. During transportation, avoid
impacts larger than those specified in Section 2.1 by using
dedicated packaging boxes and shock-absorbing palettes.
Failure to do so may cause failures in the PLC.
After transportation, verify operation of the PLC and check for
damage of the mounting part, etc.
• When
transporting
lithium
batteries,
follow
required
transportation regulations.
(For details of the regulated products, refer to FX
Series
3UC
User's Manual - Hardware Edition.)
Associated manuals
How to obtain manuals
For the necessary product manuals or documents, consult with
your local Mitsubishi Electric representative.
Associated manuals
FX
(D, DS, DSS) Series PLC (main unit) comes with this
3UC
document (hardware manual).
For a detailed explanation of the FX
Series hardware and
3UC
information on instructions for PLC programming and special
extension unit/block, refer to the relevant documents.
Manual name
Manual No.
Description
Explains FX
Series
3UC
FX
Series
JY997D28701
3UC
PLC specification details
User's Manual
MODEL CODE:
for I/O, wiring, installation,
- Hardware Edition
09R519
and maintenance.
FX
/FX
/FX
/
Describes PLC
3S
3G
3GC
FX
/FX
Series
JY997D16601
programming for basic/
3U
3UC
Programming Manual
MODEL CODE:
applied instructions STL/
- Basic & Applied
09R517
SFC programming and
Instruction Edition
devices.
MELSEC-Q/L/F
Programming methods,
SH-080782
Structured
specifications, functions,
MODEL CODE:
Programming Manual
etc. required to create
13JW06
(Fundamentals)
structured programs.
FXCPU Structured
JY997D26001
Devices, parameters, etc.
Programming Manual
MODEL CODE:
provided in structured
[Device & Common]
09R925
projects of GX Works2.
FXCPU Structured
JY997D34701
Sequence instructions
Programming Manual
MODEL CODE:
provided in structured
[Basic & Applied
09R926
projects of GX Works2.
Instruction]
FXCPU Structured
JY997D34801
Application functions
Programming Manual
MODEL CODE:
provided in structured
[Application
09R927
projects of GX Works2.
Functions]
Explains N:N link, parallel
FX Series User’s
JY997D16901
link, computer link, no
Manual - Data
MODEL CODE:
protocol communication
Communication
09R715
by RS instructions/FX
-
2N
Edition
232IF.
FX
/FX
/FX
/
Describes specifications
3S
3G
3GC
FX
/FX
Series
JY997D16701
for analog control and
3U
3UC
User's Manual
MODEL CODE:
programming methods for
- Analog Control
09R619
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
Edition
FX
Series PLC.
3UC
FX
/FX
/FX
/
Explains the specifications
3S
3G
3GC
FX
/FX
Series
JY997D16801
for positioning control of
3U
3UC
User's Manual
MODEL CODE:
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
- Positioning Control
09R620
FX
Series and
3UC
Edition
programming procedures
Certification of UL, cUL standards
FX
series main units, FX
series special adapter, extension
3UC
3U
power supply unit and FX
/FX
series input/output extension
2N
2NC
blocks supporting UL, cUL standards are as follows:
UL, cUL file number: E95239
Models:
MELSEC FX
series manufactured
3U(C)
FX
-MT/D
FX
-MT/DSS
3UC
3UC
Where  indicates: 16, 32, 64, 96
FX
-16MR/D-T
FX
-16MR/DS-T
3UC
3UC
FX
-232ADP(-MB)
FX
-485ADP(-MB)
3U
3U
FX
-CF-ADP
FX
-ENET-ADP
3U
3U
FX
-4AD-ADP
FX
-4DA-ADP
3U
3U
FX
-3A-ADP
FX
-4AD-PT-ADP
3U
3U
FX
-4AD-PTW-ADP FX
-4AD-PNK-ADP
3U
3U
FX
-4AD-TC-ADP
3U
FX
-1PS-5V
3UC
Models:
MELSEC FX
series manufactured
2NC
FX
-16EX(-DS)
FX
-32EX(-DS)
2NC
2NC
FX
-16EYT(-DSS) FX
-32EYT(-DSS)
2NC
2NC
FX
-16EX-T(-DS)
FX
-16EYR-T(-DS)
2NC
2NC
Models:
MELSEC FX
series manufactured
2N
FX
-8ER-ES/UL
FX
-8EX-ES/UL
2N
2N
FX
-8EYR-ES/UL
FX
-8EYR-S-ES/UL
2N
2N
FX
-8EYT-ESS/UL
FX
-8EX-UA1/UL
2N
2N
FX
-16EX-ES/UL
FX
-16EYR-ES/UL
2N
2N
FX
-16EYT-ESS/UL FX
-16EYS
2N
2N
Compliance with EC directive (CE Marking)
This product complies with EC directive, however, this document
does not guarantee that a mechanical system including this product
will comply with EC directive.
Compliance to EMC directive and LVD directive of the entire
mechanical system should be checked by the user / manufacturer.
For more details please contact the local Mitsubishi Electric sales
site.
Caution for Compliance with EC directive
• Please use the FX
(D, DS, DSS) Series programmable
3UC
controllers while installed in conductive shielded control panels
under a general industrial environment.
• Programmable controllers are open-type devices that must be
installed and used within conductive control panels. Please secure
the control panel lid to the control panel (for conduction). Installation
within a control panel greatly affects the safety of the system and
aids in shielding noise from the programmable controller.
• For the control panel, use the product having sufficient strength, fire
protectiveness and shielding property to an installation environment.
• 24 V DC of the power supply must be supplied from the circuit
double/reinforced insulated from the main power supply (MAINS).
Caution for compliance with the LVD directive
(EN61010-2-201:2013) (*1)
• To an external connection port other than AC power supply terminal
and AC input/output terminal, connect the circuit separated from a
dangerous voltage by a double/reinforced insulation.
• Between the commons having the adjacent relay output
terminals, if an external power supply is higher than 120 V AC,
the insulation is basic. Therefore, when using 120 V AC or higher
external power supply and 30 V DC/AC or lower external power
supply between the adjacent commons, do not handle 30 V DC/
AC or lower external power supply as a touchable part, (When
handling 30 V DC/AC or lower external power supply as a
touchable part, add a basic insulation.)
loading

Summary of Contents for Mitsubishi Electric FX3UC-16MT/DSS

  • Page 1 / manufacturer. SH-080782 disconnecting any extension cable. Structured specifications, functions, MODEL CODE: For more details please contact the local Mitsubishi Electric sales Failure to do so may cause equipment failures or malfunctions. Programming Manual etc. required to create 13JW06 Safety Precaution site.
  • Page 2 → For more details, refer to the FX Series User's Manual - Mitsubishi Electric recommends that shielded cables be used. If no Hardware Edition other EMC protection is provided, then users may experience temporary loss of accuracy between +10 %/-10 % in very heavy...
  • Page 3 Installation Location Procedures for installing to and detaching from Connection of power supply connector Notes DIN rail Install the PLC in an environment conforming to the generic Use the dedicated built-in power connector to supply power to the • When a dust proof sheet is supplied with an extension unit/ specifications (section 2.1), installation precautions and notes.
  • Page 4: Power Supply/Input/Output Specifications And Examples Of External Wiring

    Removal of the power cable Connection to input/output connector 3) Connectors for user-made input/output cables (available 2.6.2 Tightening Torque from Mitsubishi) 1) Turn the power supply OFF. The input/output connectors of the Main units (Connector type) Tighten the terminals to a torque of 0.22 to 0.25 N•m. Users should provide electric wires and a pressure bonding tool.
  • Page 5 Power supply specifications and example of 3.1.2 Example of external wiring (power type) Item Input specification (24 V DC) Notes external wiring Supply 24 V DC power to the main unit and FX -EX(-T) using -MT/D • Simultaneously turn on and off the power supplies of the main -16MR/D-T the dedicated connector.
  • Page 6 3.3.2 Handling of input terminal 2. Examples of sink input wiring (FX -MT/DSS, Output specifications and example of external 2) When using an instruction related to pulse train output or -16MR/DS-T) wiring positioning, make sure to set the load current to 10 to 100 mA 1) FX -MT/D, FX -16MR/D-T, FX...
  • Page 7: Terminal Layout

    3.4.4 Relay output specifications Cautions in input and output wiring 3.5.3 Cautions on relay output wiring Terminal Layout → For more details, refer to the FX Series User's Manual - → For more details, refer to FX Series User's Manual Notes Hardware Edition.
  • Page 8: For Safe Use

    -16EYT -32EYT Notch This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving Notch Notch industrial property rights which may occur as a result of using the contents noted in this manual.

This manual is also suitable for:

Fx3uc-32mt/dssFx3uc-64mt/dssFx2nc-16ex-dsFx2nc-32ex-dsFx2nc-16eyt-dssFx3uc-96mt/dss ... Show all