Performance Data Sheet

Model 9000 777508, 9000 705475 and 9000 225170
Use Replacement Cartridge 9000 674655.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit
for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53.
System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of
the claims specified on the Performance Data Sheet.
Capacity 739.68 Gallons (2800 Liters)
Contaminant Reduction Determined by NSF testing.
Contaminant
Average
Reduction
Influent
Chlorine Taste and
2,1 mg/l
Odor
Nominal Particulate
9.100.000 pts/ml At least 10.000
Class I, ≥ 0,5 to < 1,0
μm
Cyst*
170.000 cysts/l
* Based on the use of Cryptosporidium parvum oocysts
Application Guidelines/Water Supply Parameters
Service Flow
0.75 gpm (2.83 lpm)
Water Supply
Potable Water
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 °F - 100 °F (0.6 °C - 38 °C)
It is essential that the manufacturer's recommended installation,
maintenance and filter replacement requirements be carried out for the
product to perform as advertised. See Installation Manual for Warranty
information.
Note: While the testing was performed under standard laboratory
conditions, actual performance may vary.
Replacement Cartridge: 9000 674655. For estimated costs of
replacement elements please contact your local dealer or
call 1-800-578-6890.
WARNING
:
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before and after
the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
EPA Establishment Number 10350-MN-005
24
NSF specified
Avg %
Challenge
Reduction
Concentration
2,0 mg/L ± 10 %
97.6 %
98.8 %
particles/mL
Minimum
99.99 %
50.000 cysts/l
Average Product
Max Permissible
Water
Product Water
Concentration
Concentration
0.05 mg/L
N/A
111,817 pts/ml
N/A
0.001 cyst/L
N/A
NOTICE
To reduce the risk associated with property damage due to
water leakage or flooding:
Read and follow all Instructions before installation and use of this
system.
To reduce the risk of water leakage or flooding, and to ensure
optimal filter performance:
Change the disposable filter cartridge every six months or sooner
if you observe a noticeable reduction in water flow rate.
Failure to replace the disposable filter cartridge at recommended
intervals may lead to reduced filter performance and cracks in the
filter housing, causing water leakage or flooding.
NSF
NSF Test
Reduction
Report
Requirements
≥ 50 %
J-00121313
≥ 85 %
J-00099871
≥ 99.95 %
J-00109715