Saving The Log To A Disk - Emerson Rosemount Apex Reference Manual

Radar gauge
Table of Contents
APEX
and APEX Sentry
3-37
Radar Gauge
Start Monitoring
Start Disk Logging

Saving the log to a disk

1. Choose the desired variables to be monitored.
2. Click the Log interval button and enter a time interval. For example, type
10 if you want data to be logged every tenth of a second.
3. Click the Counter button and enter the maximum number of files to be
stored. The Counter is used to limit the amount of data stored on the
hard disk. Each time the maximum number of entries in a log file is
reached, the current log file is saved and a new file is created. This
procedure continues up to the maximum number of files given by the
Counter value. The file size is limited to 60000 entries which can easily
be handled by spreadsheet programs such as MS Excel.
4. Select the desired options of Timer, Time, and Date. By selecting a
check box the corresponding time indication is stored for each log entry
in the log file.
5. Click the Start disk logging button.
6. Choose a destination folder and enter a file name.
Reference Manual
00809-0100-4731, Rev FA
Log Interval
Counter
April 2003