Packages Of Combination Heater, Temperature Control And Solar Device - Ariston CLAS NET One Installation And Servicing Manual

Condensing wall-hung gas boiler
Hide thumbs Also See for CLAS NET One:
Table of Contents
PACKAGES
OF
COMBINATION
CONTROL AND SOLAR DEVICE
The fiche for packages of combination heater, temperature
control and solar device shall contain the elements set out in
points (a) and (b):
a) the elements set out in Figure 1, respectively, for evaluating
the seasonal space heating energy efficiency of a package
of combination heater, temperature control and solar device,
including the following information:
- I: the value of the seasonal space heating energy efficiency
of the preferential combination heater, expressed in %;
- II: the factor for weighting the heat output of the
preferential and supplementary heaters of a package
(see COMMISSION DELEGATED REGULATION (EU) No
811/2013 - annex IV - 6.a);
- III: the value of the mathematical expression: 294/(11 ·
Prated), whereby Prated is related to the preferential
combination heater;
- IV:
the value of the mathematical expression 115/(11 ·
Prated), whereby Prated is related to the preferential
combination heater;
in addition, for preferential heat pump combination heaters:
- V: the value of the difference between the seasonal space
heating energy efficiencies under average and colder
climate conditions, expressed in %;
- VI: the value of the difference between the seasonal space
heating energy efficiencies under warmer and average
climate conditions, expressed in %;
(b) the elements set out in Figure 5 for evaluating the water
heating energy efficiency of a package of combination heater,
temperature control and solar device, where the following
information shall be included:
- I: the value of the water heating energy efficiency of the
combination heater, expressed in %;
- II: the value of the mathematical expression (220 · Q ref )/Q
nonsol , where Q ref is taken from Table 15 in Annex VII
of the COMMISSION DELEGATED REGULATION (EU) N.
811/2013 and Q nonsol from the product fiche of the solar
device for the declared load profile M, L, XL or XXL of the
combination heater;
- III: the value of the mathematical expression (Qaux · 2,5)/
(220 · Qref), expressed in %, where Q aux is taken from
the product fiche of the solar device and Q ref from
Table 15 in Annex VII of the COMMISSION DELEGATED
REGULATION (EU) N. 811/2013 for the declared load
profile M, L, XL or XXL.