# Display power information for GigabitEthernet 2/0/1.
display poe interface power gigabitethernet 2/0/1
Interface
GE2/0/1
# Display power information for all PIs.
display poe interface power
Interface
GE2/0/25
GE2/0/26
GE2/0/27
GE2/0/28
GE2/0/29
GE2/0/30
--- On State Ports: 3; Used: 23.8(W);
Table 24 Command output
Field
Interface
CurPower
PeakPower
MaxPower
PD Description
Ports On
Used
Remaining

display poe power-usage

Use display poe power-usage to display power usage statistics for PoE power supplies and PSEs.
Syntax
Distributed devices in standalone mode/centralized devices in standalone mode:
display poe power-usage
Distributed devices in IRF mode:
display poe power-usage [ chassis chassis-number ]
Centralized devices in IRF mode
display poe power-usage [ slot slot-number ]
Views
Any view
Current
Peak
(W)
(W)
15.0
15.3
Current
Peak
(W)
(W)
4.4
4.5
4.4
4.5
15.0
15.3
0.0
0.0
0.0
0.0
0.0
0.0
Description
Interface name of a PI.
Current power of a PI.
Peak power of a PI.
Maximum power of a PI.
Type and location description for the PD connected to a PI.
Number of PIs that are supplying power.
Power consumed by all PIs.
Total remaining power of the system.
Max
PD Description
(W)
15.4
Access Point on Room 509 for Peter
Max
PD Description
(W)
4.6
IP Phone in Room 309 for Peter Smith
15.4
IP Phone in Room 409 for Peter Pan
15.4
Access Point in Room 509 for Peter
0.0
IP Phone in Room 609 for Peter John
0.0
IP Phone in Room 709 for Jack
0.0
IP Phone in Room 809 for Alien
Remaining: 776.2(W) ---