Emerson Fisher GX Instruction Manual page 25

And actuator system
Hide thumbs Also See for Fisher GX:
Table of Contents
Instruction Manual
D103175X012
Figure 9. Fisher GX Travel Stop Orientation
ACTUATOR
ROD
STEM
CONNECTOR
APPLY
LITHIUM
GREASE TO
LEVERS
DOWNSTOP
Setting the Travel Stop Position
After sending the required position air signal to the actuator, screw the adjustable cap screws to assure the lever
contacts with the stem connector tightly, then tighten the back nut. Check the actual stem position when giving the
100% air signal.
Standard Accuracy for the travel stop position is +/- 10% for 20 mm travel. For added precision, use the following
procedure.
1. Send the desired position air signal to the actuator.
2. Set the travel stop, screw the adjustable cap screws to assure the lever contacts with the stem connector tightly,
then tighten the back nut.
3. Send a 100% air signal.
4. Measure the difference between the actual stem position and the desired position.
5. Send the air signal for the desired position minus the differential position measured in step 4.
6. Reset the travel stop by adjusting the two cap screws and then tighten the back nut.
BRACKET
LEVER
BACK NUT (2)
ADJUSTABLE
CAP SCREW (2)
RETAINING RING
SHAFT
APPLY
LITHIUM
GREASE TO
LEVERS
STEM
CONNECTOR
UPSTOP
GX Valve and Actuator
April 2011
ACTUATOR
ROD
LEVER
SHAFT
RETAINING RING
ADJUSTABLE
CAP SCREW (2)
BACK NUT (2)
BRACKET
25

Hide quick links:

Table of Contents
loading

Table of Contents