DESTINATION: Z
Items
Source
Climate class
Thermostat
Damper thermostat
Timer
Fuse ass'y
Defrost thermostat
Door switch
Lamp socket
Lamp
Fan motor
Compressor
Starting relay
Overload relay(Protector)
Running capacitor
Defrost heater
SJ-48G, SJ-D48G
220V 50/60Hz
T
Type: MM1-8025 ON: –17±5˚C OFF: –22±1.5˚C(at normal notch)
Type: MM1-6129
Baffle opened 1.5˚C(at normal notch)
Baffle closed –3±1.5˚C
Type: TMDF904FD2, Integration type
Cycle 10hours 50 min., Working time about 4min. 20sec. 50Hz
Thermo. fuse Type: SF70E 250V 10A Working temp. 70±2˚C
or MTG4A50072 250V 10A Working temp. 72±2˚C
Type: US602S 250V 8A OPEN 10±3˚C CLOSE 1±3˚C
3 terminals push-button 250V 0.25A
250V 1A E-12(HARD PLASTIC BODY TYPE)
240V 10W E-12
Type: MH15SAF-TJA7 200/240V 50Hz 0.8W
Type: GL-99BL
50/60Hz(OIL COOLING)
Cooling capacity 244W/279W
Main coil 6.68Ω
Aux. coil 9.30Ω ( at 20˚C)
Terminal
Common
Aux. coil
Main coil
PTC/UH-3003 14Ω 350V
4TM306NFBYY OFF 120˚C ON 61˚C
6µF / 400V
220V 137W
353Ω
SJ-51G, SJ-D51G, SJ-55G, SJ-D55G
8
Table of Contents