Electric Specifications - Samsung DVM PLUS III Technical Data Book

Hide thumbs Also See for DVM PLUS III:
Table of Contents
4

Electric specifications

4-1. Basic models
Classification
Capacity (Ton)
Single unit
Model
RVXVHT075FE
RVXVHT100FE
RVXVHT125FE
 All wiring, components and materials to be procured on the site must comply with the applicable local and national codes.
4-2. Combinations
Capacity
Classification
(Ton)
12
14
16
18
20
Module unit
22
24
26
28
30
Model
Hz
RVXVHT150FE
60 208~230
RVXVHT175FE
60 208~230
RVXVHT200FE
60 208~230
RVXVHT225FE
60 208~230
RVXVHT250FE
60 208~230
RVXVHT275FE
60 208~230
RVXVHT300FE
60 208~230
RVXVHT325FE
60 208~230
RVXVHT350FE
60 208~230
RVXVHT375FE
60 208~230
 The relationship between the starting time and the starting current (Digital Scroll Comp. + Fixed Scroll Comp)
 RLA is based on the following conditions.
- Indoor temp. : 80˚F DB/ 67˚F WB
- Outdoor temp. : 95˚F DB
 Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminal is not below or above listed range limits.
 Maximum allowable voltage variation between phases is 2%.
 Select wire size based on the value of MCA.
 MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
 Abbreviations
- MCA: Min. Circuit Amps. (A)
MCA = 1.25 X LOAD1 + LOAD2
(LOAD1: RLA of Digital Comp. / LOAD2: RLA of Fixed Comp. + FLA of Fan Motor)
- MFA: Max. Fuse Amps. (A)
- RLA: Rated Load Amps. (A)
- OFM: Outdoor Fan Motor
- FLA: Full Load Amps. (A)
- kW : Rated Motor Output (kW)
Capacity (HP)
6
7.5
8
10.0
10
12.5
Units
Hz
Volts
Min.
Max.
60
208~230
187
60
208~230
187
60
208~230
187
Capacity
(HP)
RVXVHT075FE
15.0
2
17.5
1
20.0
22.5
25.0
27.5
1
30.0
32.5
35.0
37.5
Units
Volts
Min.
Max.
MCA
187
253
96.2
187
253
101.9
187
253
107.6
187
253
114.9
187
253
122.2
187
253
155.7 50+50+50 (13.8+21.8)+(19.6+21.8)×2
187
253
161.4 50+50+50
187
253
168.7 50+50+60 (19.6+21.8)×2+(23.4+24.6)
187
253
176.0 50+60+60 (19.6+21.8)+(23.4+24.6)×2
187
253
183.3 60+60+60
Model
MCCB(A)
RVXVHT075FE
50
RVXVHT100FE
50
RVXVHT125FE
60
Power supply
MCA
MFA
253
48.1
50
13.8 + 21.8
253
53.8
50
19.6 + 21.8
253
61.1
60
23.4 + 24.6
Basic model
RVXVHT100FE
RVXVHT125FE
1
2
1
2
3
2
1
Power supply
MFA
50+50
(13.8+21.8)×2
50+50
(13.8+21.8)+(19.6+21.8)
50+50
(19.6+21.8)×2
50+60
(19.6+21.8)+(23.4+24.6)
60+60
(23.4+24.6)×2
(19.6+21.8)×3
(23.4+24.6)×3
RLA
Starting time
ELB
50A, 30mA 0.1 Second or less
50A, 30mA 0.1 Second or less
60A, 30mA 0.1 Second or less
Comp.
OFM
RLA
kW
0.63
0.63
0.63
MCCB(A)
50 + 50
50 + 50
50 + 50
1
50 + 60
2
60 + 60
50 + 50 + 50
50 + 50 + 50
1
50 + 50 + 60
2
50 + 60 + 60
3
60 + 60 + 60
Comp.
RLA
kW
0.63+0.63
0.63+0.63
0.63+0.63
0.63+0.63
0.63+0.63
0.63+0.63+0.63 7+7+7
0.63+0.63+0.63 7+7+7
0.63+0.63+0.63 7+7+7
0.63+0.63+0.63 7+7+7
0.63+0.63+0.63 7+7+7
FLA
7
7
7
ELB
OFM
FLA
7+7
7+7
7+7
7+7
7+7
45
Table of Contents