Panasonic FX-501 Series Instruction Manual

Panasonic FX-501 Series Instruction Manual

Digital fiber sensor amplifier
Digital Fiber Sensor Amplifier
FX-501□, FX-502□, FX-505□-C2 Series
Thank you for purchasing products from Panasonic Electric Works SUNX
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use prod‑
ucts which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
1
compliance with standards
This product complies with the following standards and
regulations.
● For the EU: EMC Directive 2004/108/EC
● For the US and Canada:
ANSI/UL60947‑5‑2, CAN/CSA C22.2 No.14
● For Korea: S1‑G‑1‑2009, S2‑W‑5‑2009
*
In case you require a ul listing mark or c-ul
listing mark, use a class 2 power supply unit.
2
Part description
FX-501□
1
2
9
1
Operation indicator for sensing output (orange)
2
Digital display (green / red)
3
UP key (+)
Functions:
● Teach
4
DOWN key (–)
● Fine adjustment of the threshold value
● Select settings
5
MODE key
Functions:
● Select modes
● Cancel
6
SET key
Functions:
● Teach
● Save selected settings
7
Mode indicator PRO mode (yellow), see page 6
8
Mode indicator CUST (custom) mode (yellow), see page 5
9
Mode indicator L /D (Light‑ON / Dark‑ON) mode (yellow)
FX-502□ and FX-505□-C2
1 2
3
0
1,
Sensing output 1 (lit if output is active)
● Yellow: Sensing output is selected
● Orange: Sensing output is operating
2
Sensing output 2 (lit if output is active)
● Yellow: Sensing output is selected
● Orange: Sensing output is operating
3
Digital display (green / red)
InstructIon Manual
WARNING
3
4
8
7
6
5
4
5
9
8
7
6
4
UP key (+)
Functions:
5
DOWN key (–)
6
MODE key
Functions:
7
SET key
Functions:
8
Mode indicator PRO mode (yellow)
9
Mode indicator CUST (custom) mode (yellow)
0
Mode indicator L /D (Light‑ON / Dark‑ON) mode (yellow)
*
To toggle the key lock function ON/OFF, press the SET and the
MODE key together for 3 seconds.
3
Mounting
Installation to a DIn rail
1. Attach the railing on the rear of the ampli‑
fier to the DIN rail.
2. Push the amplifier in the direction of the
arrow as illustrated so that it attaches
securely.
removal from a DIn rail
1. Push the amplifier forward.
2. Lift the front part of the amplifier up.
Connecting the fiber cable
*
The attachments to the fiber cables need to be fitted BEFORE
you insert the fibers into the amplifier. For details, refer to the
instruction manual enclosed with the fibers.
1. Snap the fiber lock lever 1 down as
far as it will go.
2. Insert the fiber cables slowly into the
inlets until they stop (see note).
3. Return the fiber lock lever to the
original position.
*
With the coaxial reflective type fiber, such as FD-G4 or FD-FM2,
insert the single core fiber cable into the inlet for the emitter 2
(inlet on the amplifier is labeled "P") and the multi-core fiber
cable into the inlet for the receiver 3. If they are inserted the
wrong way round, the sensing performance will deteriorate.
1
● Teach
● Fine adjustment of the threshold value
● Select settings
● Select modes
● Cancel
● Teach
● Confirm selected settings
2.
2.
3.
1.
2.
2
3
1.
1.
1
Table of Contents
loading

Summary of Contents for Panasonic FX-501 Series

  • Page 1 MODE key Functions: FX-501□, FX-502□, FX-505□-C2 Series ● Select modes ● Cancel Thank you for purchasing products from Panasonic Electric Works SUNX SET key Functions: ● Teach Co., Ltd. Please read this Instruction Manual carefully and thoroughly for ● Confirm selected settings the correct and optimum use of this product.
  • Page 2: Cascading Amplifiers Of The Series Connection Type

    FX-502 (NPN type) Cascading amplifiers of the series connection type Brown, +V (see note) Cascading is not available for FX-505□-C2. White, sensing output 2 / Load ● You can only cascade amplifiers of the series connection type, i.e. external input 12–24V DC FX‑501□...
  • Page 3 2-point teaching operation procedure The basic teaching method when the sensing object is present is 2-point teaching. ● If you change settings, press the SET key before you turn the power OFF. Otherwise your changes will be lost. Thru-beam type Reflective type ●...
  • Page 4 If you select a value exceeding the maximum/minimum, the Display when stable sensing is possible. sensitivity will be set automatically to the maximum/minimum value. Display when stable sensing is not possible. 3-point teaching in window comparator and hysteresis mode 1-point teaching in window comparator and hysteresis mode With this method, you set the threshold range by performing teaching with With this method, you set the threshold range by setting the shift amount three sensing objects with different incident light intensities (P‑1, P‑2, and...
  • Page 5: Threshold Value Fine Adjustment Function

    Threshold value fine adjustment function Sensing output operation mode (L/D) ● The fine adjustment of the threshold value can be set in RUN mode, When the mode indicator L /D (yellow) is ON, you can switch from Light‑ON mode to Dark‑ON mode and vice versa. forced ON output mode and forced OFF output mode.
  • Page 6: Interference Prevention Function

    PRO mode (PRO) optical communication ● When the mode indicator PRO (yellow) is ON, you can scroll through It is possible to use optical communication for the following functions. the PRO menu (Pro1 to Pro7) and make advanced settings. ● Data bank loading / saving (use FX-502□ or FX-505□-C2 as the main amplifier) ●...
  • Page 7: Error Codes And Troubleshooting

    tion can cover, you need to prevent interference manually with one of the cautions two following methods: ● Attach the amplifier protection seal FX-MB1 to the communication win‑ ● This product has been developed / produced for industrial use only. dow between the last amplifier in the valid range and the first amplifier ●...
  • Page 8: Specifications

    2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 Europe Headquarter: Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany Phone: +49-8024-648-0 US Headquarter: Panasonic Electric Works Corporation of America 629 Central Avenue, New Providence, New Jersey 07974, USA Phone: +1-908-464-3550...