Honeywell CL15AC Owner's Manual

Honeywell CL15AC Owner's Manual

Portable evaporative air cooler
Hide thumbs Also See for CL15AC:
Portable Evaporative Air Cooler
OWNER'S MANUAL
Read and save these instructions before use.
15AC
Power rating: 126 Watts
For product enquiry or support contact :
Voltage rating:
2
2
0
2 -
4
0
V
o
t l
A
, C
5
0
H
z
C
U
S
T
O
M
E
R
C
A
R
E
:
1
3
0
0
7
1
0
8
60
www.honeywellaircoolers.com
Made in China
Table of Contents
loading

Summary of Contents for Honeywell CL15AC

  • Page 1 Portable Evaporative Air Cooler OWNER’S MANUAL Read and save these instructions before use. 15AC Power rating: 126 Watts For product enquiry or support contact : Voltage rating: www.honeywellaircoolers.com Made in China...
  • Page 2 This page is intentionally left blank...
  • Page 3: Table Of Contents

    INDEX Read all instructions carefully before setting up and operating the unit, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty.
  • Page 4: Thank You

    THANK YOU THANK YOU! Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler . For optimum cooling performance from your unit, fill the water tank with water & ice (if available) to increase its cooling performance.. The unit should be positioned in a location that will create a 'flow through' air effect.The greatest cooling effect will be felt if the unit is operated in a partly opened doorway or window.
  • Page 5: User Tips

    USER TIPS NATURAL ENERG Y EFFICIENT COOLING .. Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake. This breeze drops the temperature and has a relaxing cooling effect. The evaporative air cooler cools the air by means of the evaporation of water. When water evaporates into the air, the result is a mixture of air and water molecules.
  • Page 6 USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces.
  • Page 7: Safety Rules

    SAFETY RULES READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: Your unit runs on 220-24 0 Volt AC, 50 Hz current. Check the • household voltage to ensure it matches the appliance's rate 220 - 24 0 Volt AC, 5 0Hz specification.
  • Page 8 SAFETY RULES • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. DO NOT cover the air inlet or outlet on the appliance as this • may cause motor damage. •...
  • Page 9: Parts Description

    PARTS DESCRIPTION 1 Outlet Louvers Top Panel (Horizontal-Manual & 10 Rear Panel Grill 11 Right Side Panel Vertical-Automatic Swing) 12 Air Inlet Louvers 2 Control Panel 13 Honeycomb Media 3 Front Panel 4 Front Castors / Wheels 14 Water Tank (Cannot be Removed) 5 Side Handle 15 Rear Castors / Wheel 6 Left Side Panel...
  • Page 10: Use & Operation

    USE & OPERATION CONTROL PANEL Speed Button Timer Button Swing Button Power Button Cool Button COOL SPEED TIMER SWING POWER Power ON/OFF Indicator LCD Display Panel...
  • Page 11: Function Buttons

    USE & OPERATION FUNCTION BUTTONS POWER Press the 'POWER' button to turn the unit on. To turn the unit off, press the button again. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. POWER SPEED Press the 'SPEED' button repeatedly and the speed will...
  • Page 12 USE & OPERATION SWING Press the ''SWING '' button. The indicator light will come on and the louvers will begin to move from right to left automatically. Manually adjust the horizontal louvers to change vertical airflow. SWING LOUVERS MOVEMENT TIMER Press the ''TIMER'' button until the indicator light comes on to your desired timer.
  • Page 13: Low Water Alarm And Cooler Location

    USE & OPERATION LOW WATER ALARM FUNCTION The unit is equipped with a low water sensor. When water in the tank is below the minimum level, you will hear 10 beeps and the COOL LED indicator will flash continuously. At the same time the power to the pump inside the unit will be cut off to protect the life of the pump.
  • Page 14: Remote Control

    USE & OPERATION REMOTE CONTROL On / Off POWER Low / Medium / High SPEED Controls cooling or fan option COOL Controls the motion of the louvers SWEEP Controls timer function for automatic shut off TIMER Remote Control ( Batteries not included) NOTE •...
  • Page 15: Fill Water

    USE & OPERATION FILL WATER Pull out the Water Fill Door located below the left side panel (refer page 7) and fill water till the Max. Level, as indicated on the Water Level Indicator. The water tank of this unit holds up to 15 Litres of water.
  • Page 16: Cleaning & Maintenance

    CLEANING & MAINTENANCE WARNING • Before cleaning the unit, switch it to the ''off'' position and remove the plug from the power socket. • To clean the outside, use a damp cloth to remove dirt and dust. • Never use detergents, corrosive elements or any chemicals to clean this product. •...
  • Page 17 CLEANING & MAINTENANCE CLEANING THE HONEYCOMB FILTER • Turn off the unit, and unplug the power cord from wall outlet. • Rotate the unit facing the back panel, and locate the Rear Grill Removal Screws (refer page 7., No. 17). Remove both the screws with a screw driver. •...
  • Page 18: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Cooler not operating Initially. Cord is not plugged in. Make sure power cord is plugged in and the supply switch in ON. Power outlet or supply faulty. Check the power outlet. Check the power supply. Check that the power supply is I ncorrect Voltage.
  • Page 19 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION The unit does not respond Remote control batteries. Check batteries, Replace if needed. Try to operate using the control panel. Damaged PCB Try with remote control. If the unit responds, PCB board fasteners may be loose. Contact service centre.
  • Page 20: Technical Specifications

    TECHNICAL SPECIFICATIONS MODEL NO. CL15AC Voltage 220V- 240V 50Hz Frequency Wattage 126 Watts Water Tank Capacity 15 Liters Cooling Media Honeycomb Product Dimension 380(L) x 380(W) x 795(H) mm 9.9 Kg Net Weight ELECTRICAL WIRING DIAGRAM COOL SWEEP PLUG-IN PLUG...
  • Page 21: Service And Warranty

    SERVICE AND WARRANTY LIMITED TWO (2) YEARS WARRANTY All Honeywell evaporative air coolers purchased from Honeyair Australia Pty Ltd. are guaranteed to be • free from manufacturing defects, workmanship or parts and carry a (2) year exchange warranty from the date of first retail purchase thereof.
  • Page 22 National Distributor of Honeywell Evaporative Air Coolers : Honeyair Austrialia Pty. Ltd. elmont, July 2010, IM02 - CL15AE - 2010 - 07 © 2010 AirTek International Corporation Limited a i l The Honeywell Trademark is used under license from Honeywell International Inc.

Table of Contents