Parameter list
PNU
Description
P594
Source for input quantity of "Polarity signal"
*
Polarity signal of speed setpoint:
Selection of connector to be injected as input quantity "n set " for the polarity
(G188)
signal of the speed setpoint.
0 = connector K0000
1 = connector K0001
etc.
P595
Source for actual value of "Overspeed signal"
*
Overspeed signal:
Selection of connector to be injected as input quantity "n act " for the
(G188)
overspeed signal.
0 = connector K0000
1 = connector K0001
etc.
P596
Source for setpoint of "nset = nact signal 2"
*
Setpoint/actual value deviation signal:
Selection of connector to be injected as input quantity "n set " for the
(G187)
setpoint/actual value deviation signal.
0 = connector K0000
1 = connector K0001
etc.
P597
Source for actual value of "nset = nact signal 2"
*
Setpoint/actual value deviation signal:
Selection of connector to be injected as input quantity "n act " for the
(G187)
setpoint/actual value deviation signal.
0 = connector K0000
1 = connector K0001
etc.
11.32 Configuring of closed-loop control
Setting values for configuring of torque shell
P600
Source for gating unit input
*
i001 to i004:
(G163)
Selects which connectors are applied as the gating unit input .
All four values are added.
Settings:
0 = connector K0000
1 = connector K0001
etc.
P601
Source for current controller setpoint
*
i001,i002 Speed limiting controller:
Selection of connectors to be injected as input quantities for
(G160)
the speed limiting controller. Both values are added.
(G161)
(G162)
i003,i004 Current limitation:
Selection of connectors to be injected as current controller
setpoint (before current limitation). Both values are added.
i005,i006 Current control:
Selection of which connectors are connected as the current
controller setpoint (before current controller). The two
values are added. The magnitude is formed from the value
selected with index 6.
Settings:
0 = connector K0000
1 = connector K0001
etc.
11-44
Value range
[Unit]
All connector
numbers
1
All connector
numbers
1
[SW 1.9 and later]
All connector
numbers
1
[SW 1.9 and later]
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
[SW 1.8 and later]
No. indices
Ind: None
FS=170
Type: L2
Ind: None
FS=167
Type: L2
Ind: None
FS=174
Type: L2
Ind: None
FS=167
Type: L2
Ind: 4
FS=
i001: 102
i002: 0
i003: 0
i004: 0
Typ: L2
Ind: 6
FS=
i001: 141
i002: 0
i003: 134
i004: 0
i005: 125
i006: 0
Type: L2
SIEMENS AG
6SG7000-0BA76
SIMOTRAS HD
Operating Instructions
01.04
See
Change
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline