Sensor testing should be done before and after permanent
mounting.
Comm Testing
If Comm Test is not finished, it will continue to run even if you
exit program mode.
Note: Complete panel programming before performing comm
testing.
To perform a comm test:
1.
Enter the Status & Settings menu.
2.
Scroll until System Tests is listed, Press Enter.
3.
Enter your master code and press OK.
4.
Press Comm Test.
The panel displays if the comm test was successful or not.
Central station communication
After performing sensor tests, check that the system is
reporting alarms successfully to the central station.
Note: The communication with the central station test must be
done while NOT in programming mode.
To verify alarm reporting:
1.
Call the central station and tell the operator that you will be
testing the system.
2.
Arm the system.
3.
Test an emergency panic icon and trip at least one sensor
of each type (fire, intrusion, etc.) to verify that the
appropriate alarms are working correctly. There is a 30
second delay.
4.
When you finish testing the system, call the central station
to verify that the alarms were received.

Cleaning the touch screen

If necessary, use a soft cloth to clear smudges on the touch
screen. Do not use glass cleaner on the touch screen.

Disposal

Dispose of all equipment is accordance with local requirements

Specifications

10
Power
9 VAC, 60 Hz, 25 VA transformer minimum
Rechargeable battery: 6.0 VDC, 2.1 Ah NIMH.
Maximum battery charging current is 120 mA.
Once the battery reaches a low battery
condition, a trouble signal will be annunciated,
indicating that the battery may no longer
support a full alarm load.
When fully charged, the battery will operate the
panel without AC power for 24 hours with the
panel in a normal, standby condition, followed
by 5 minutes in full alarm condition (including
the maximum specified auxiliary load of 250
mA).
Radio frequency
319.5 MHz
Storage temperature
-29 to 140ºF (-34 to 60ºC) without battery
14 to 86ºF (-10 to 30ºC) with battery one year
shelf life
Operating
32 to 120ºF (0 to 49ºC)
temperature
Maximum humidity
85% relative humidity, noncondensing
Auxiliary power
Unregulated 4.0 to 12.3 VDC, with a maximum
of 250 mA

Regulatory Information

Some installation may require configurations dictated by
city/state codes, insurance, or Underwriter's Laboratories (UL).
This section describes the various component and
configuration listings.
Basic system:
Control panel: Backup battery 6 V 2.1 Ah (34-070)
Standard Class 2, 9 VAC, 25 VA power transformer (UTC
Fire & Security part 22-155) or Standard Class 2, 9 VAC,
25 VA power transformer (UTC Fire & Security part 22-
165) or Standard, Class 2, 9 VAC, 30 VA (UTC Fire &
Security part 22-153).
Hardwired siren (13-374)
Household burglary alarm system unit (UL 1023), basic system
plus the following:
Hardwired magnetic contact (1038T) or wireless learn
mode door/window sensor (60-670-95R or
60-362N-10-319.5 or 60-362N-11-319.5)
Panel piezo beeps set to on
Entry delay set to 45 seconds or less
Exit delay set to 60 seconds or less
RF time-out set to 24 hours
Control panel alarms turned on
Auto arm set to on
Siren timeout set to 5 minutes or more
Trouble beeps set to on
RF jam detect set to on
Hardwired siren supervision set to on
Exit extension set to off
Quick exit set to off