Jumper Register
Bit
Address
READ
Base + 16
16
Note
Appendix B
The Channel Program Jumper Register returns the state of the P/J jumper on
each channel. Additional information about these jumpers is given on page 31.
15
14
13
12
11
Ch
Ch
Ch
Ch
Ch
16
15
14
13
12
Jmpr
Jmpr
Jmpr
Jmpr
Jmpr
Ch XX Jmpr: A one (1) in a field indicates that the P/J jumper is in the
program selectable position. A zero (0) indicates the P/J jumper is set to the
jumper selectable position.
When the P/J jumper is in the program selectable position (1), the channel
can be programmed to either the voltage or current mode from the VXIbus
backplane. When the P/J jumper is in the jumper selectable position (0), the
voltage or current output mode is set via the V/I jumper on the terminal
module and can not be programmed from the VXIbus backplane.
Channels 09 through 16 will return ones (1) if the module is configured as
an 8-channel device.
10
09
08
07
06
Ch
Ch
Ch
Ch
Ch
11
10
09
08
07
Jmpr
Jmpr
Jmpr
Jmpr
Jmpr
HP E1418A Register-Based Programming
05
04
03
02
01
Ch
Ch
Ch
Ch
Ch
06
05
04
03
02
Jmpr
Jmpr
Jmpr
Jmpr
Jmpr
00
Ch
01
Jmpr