2.9

Removal of PCB

Procedure
Step
1.
Removal of the control
PCB
Remove the screw of
1
the electrical box cover.
2
Detach the insulation
sheet.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Electrical box (cover)
(R9955)
(R9956)
Insulation sheet
Earth terminal
(R9957)
Outdoor Unit
Points
Preparation
Remove the panels, plates,
and electrical box according
to the removal procedure.
The control PCB is adopted
upside-down.
The lead-free solder (PbF) is
used on PCB. When
exchange, use exclusive
solder and soldering gun.
The trimmed part goes front.
The terminal board is united
with thermal fuse.
236