Capacity Compensation Rate For Pipe Length; Capacity Compensation Rate For Pipe Length And Height Difference - Fujitsu ASU24CL1 Design & Technical Manual

Wall mounted type
Hide thumbs Also See for ASU24CL1:
Table of Contents
5.

CAPACITY COMPENSATION RATE FOR PIPE LENGTH

AND HEIGHT DIFFERENCE
MODEL
: AOU24CL1
„
„
COOLING
Û 1
Indoor unit is
upper than
outdoor unit.
Height
difference
H
(m)
Û 2
Indoor unit is
under than
outdoor unit
Indoor unit
Connection pipe
 1 Indoor unit is upper than outdoor unit.
5
16ft.
20
66ft.
-
10
33ft.
-
7.5
25ft.
-
0.988
5
16ft.
0.995
0.992
0
0ft.
1.003
1.000
-5
-16ft.
1.003
1.000
-7.5
-25ft.
-
1.000
-10
-33ft.
-
-20
-66ft.
-
Height difference H
Outdoor unit
- (02 - 05) -
Pipe length (m)
7.5
10
15
25ft.
33ft.
49ft.
-
-
-
-
0.980
0.966
0.984
0.970
0.988
0.974
0.996
0.982
0.996
0.982
0.996
0.982
-
0.996
0.982
-
-
-
Outdoor unit
Connection pipe
 2 Indoor unit is under than outdoor unit.
20
25
30
66ft.
82ft.
98ft.
0.951
0.951
0.950
0.967
0.967
0.966
0.971
0.971
0.970
0.975
0.975
0.974
0.983
0.983
0.982
0.983
0.983
0.982
0.983
0.983
0.982
0.983
0.983
0.982
0.983
0.983
0.982
Indoor unit
Table of Contents
loading

This manual is also suitable for:

Aou24cl1

Table of Contents