Sharp AH-A07BE Service Manual

Split system room air conditioners
Hide thumbs Also See for AH-A07BE:
SPECIFICATIONS ............................................................................................................................................. 2
EXTERNAL DIMENSIONS ................................................................................................................................ 4
WIRING DIAGRAMS ......................................................................................................................................... 6
ELECTRICAL PARTS ........................................................................................................................................ 9
MICROCOMPUTER CONTROL SYSTEM ...................................................................................................... 13
FUNCTIONS .................................................................................................................................................... 17
TROUBLESHOOTING OF THE CONTROL CIRCUIT .................................................................................... 24
REFRIGERATION CYCLE .............................................................................................................................. 29
PERFORMANCE CURVE ............................................................................................................................... 31
DISASSEMBLING PROCEDURE .................................................................................................................... 33
REPLACEMENT PARTS LIST ........................................................................................................................ 41

SERVICE MANUAL

ROOM AIR CONDITIONERS
INDOOR UNIT
AH-A07BE/A09BE/A12BE
MODELS
AH-A07BE-C/A09BE-C
AY-A07BE/A09BE/A12BE
AY-A07BE-C/A09BE-C
OUTDOOR UNIT
AU-A07BE/A09BE/A12BE
AU-A07BE-C/A09BE-C
AE-A07BE/A09BE/A12BE
In the interests of user-safety (Required by safety regulations in
some countries)
condition and only parts identical to those specified should be
used.

TABLE OF CONTENTS

SHARP CORPORATION
1
SPLIT SYSTEM
the set should be restored to its original
AH-A07BE-C/09BE-C
AH-A07BE/09BE/12BE
AY-A07BE-C/09BE-C
AY-A07BE/09BE/12BE
S4216AYA09BE/
Page
Table of Contents
loading

Summary of Contents for Sharp AH-A07BE

  • Page 1: Table Of Contents

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE SERVICE MANUAL S4216AYA09BE/ SPLIT SYSTEM ROOM AIR CONDITIONERS INDOOR UNIT AH-A07BE/A09BE/A12BE MODELS AH-A07BE-C/A09BE-C AY-A07BE/A09BE/A12BE AY-A07BE-C/A09BE-C OUTDOOR UNIT AU-A07BE/A09BE/A12BE AU-A07BE-C/A09BE-C AE-A07BE/A09BE/A12BE In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
  • Page 2: Specifications

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE SPECIFICATIONS ITEMS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT AY-A07BE AE-A07BE AY-A07BE-C AE-A07BE-C Cooling capacity Heat pump Heating capacity Moisture removal Liters/h Electrical data Phase – Single Rated frequency Rated voltage range 198 to 264...
  • Page 3 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE ITEMS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT AY-A09BE AE-A09BE AY-A09BE-C AE-A09BE-C AY-A12BE AE-A12BE Cooling capacity 2.64 Heat pump Heating capacity Moisture removal Liters/h Electrical data Phase – Single Rated frequency...
  • Page 4 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE ITEMS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT AH-A07BE AU-A07BE AH-A07BE-C AU-A07BE-C Cooling capacity Moisture removal Liters/h Electrical data Phase – Single Rated frequency Rated voltage range 198 to 264 Rated voltage 220 - 240 Rated current 3.1 - 3.0...
  • Page 5 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE ITEMS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT AH-A09BE AU-A09BE AH-A09BE-C AU-A09BE-C AH-A12BE AU-A12BE Cooling capacity 2.64 Moisture removal Liters/h Electrical data Phase – Single Rated frequency Rated voltage range 198 to 264...
  • Page 6: External Dimensions

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE EXTERNAL DIMENSIONS 18.5 Length unit (mm) INVERTER AIR CONDITIONER Remote controller Figure E-1. INDOOR UNIT 20˚ Figure E-2. OUTDOOR UNIT FOR AE-A07BE/AE-A07BE-C AND AU-A07BE/AU-A07BE-C...
  • Page 7 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE 37.5 179.5 182.5 Figure E-3. OUTDOOR UNIT FOR AE-A09BE/AE-A09BE-C/A12BE AND AU-A09BE/AU-A09BE-C/A12BE...
  • Page 8: Wiring Diagrams

    EVAPORATOR SUPPLY : BLACK : RED : BLUE G ( Y ) : GREEN-YELLOW : BROWN MOTOR Figure W-1. Wiring Diagram for AH-A07BE/A07BE-C/A09BE/A09BE-C/A12BE INDOOR UNIT OUTDOOR UNIT COMPRESSOR MOTOR TERMINAL BOARD 2 TERMINAL BOARD MOTOR PROTECTOR G(Y) INTERNAL CONTROL BOX...
  • Page 9 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE INDOOR UNIT OUTDOOR UNIT COMPRESSOR MOTOR TERMINAL BOARD 2 TERMINAL BOARD MOTOR PROTECTOR G(Y) INTERNAL CONTROL BOX THERMAL FUSE G(Y) FAN MOTOR G(Y) TERMINAL BOARD 1 FAN MOTOR CAPACITOR POWER SUPPLY 400(450)V 1.5µF RUNNING CAPACITOR : BLACK : WHITE 400V 30µF...
  • Page 10 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE BCN201 INDOOR UNIT OUTDOOR UNIT BCN1 RECEIVER CONTROL BOARD UNIT TERMINAL BOARD 2 UNIT C.T. DISPLAY UNIT BCN2 BCN202 TRANSFORMER G ( Y ) THERMISTOR (PIPE TEMP.) TERMINAL BOARD 1 250V TERMINAL THERMISTOR BOARD (ROOM TEMP.) TEMP.FUSE...
  • Page 11 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE INDOOR UNIT OUTDOOR UNIT COMPRESSOR MOTOR TERMINAL BOARD 2 TERMINAL BOARD MOTOR PROTECTOR INTERNAL G ( Y ) THERMAL FUSE CONTROL BOX VALVE FAN MOTOR COIL G ( Y ) G ( Y ) TERMINAL BOARD 1...
  • Page 12: Electrical Parts

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE ELECTRICAL PARTS For Models AY-A07BE/A07BE-C, AH-A07BE/A07BE-C, AE-A07BE/A07BE-C, AU-A07BE and AU-A07BE-C DESCRIPTION MODEL REMARKS SITE Compressor QK134PA13A 220 - 240V, 50Hz, 620W AE/AU-A07BE Compressor RH135VHST 220 - 240V, 50Hz, 650W AE-A07BE-C Compressor RH130VHST 220 - 240V, 50Hz, 650W...
  • Page 13: Microcomputer Control System

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE MICROCOMPUTER CONTROL SYSTEM...
  • Page 14 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE...
  • Page 15 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE FROM TERMINAL BOARD (UNIT) " 1 " FROM TERMINAL BOARD (POWER) " 1 " FROM TERMINAL INDOOR BOARD FAN MOTOR " 2 " INDOOR (R.P.M. SIGNAL) FAN MOTOR FROM TERMINAL BOARD FROM FROM FROM (UNIT) " N "...
  • Page 16 (POWER) " 1 " FROM TERMINAL BOARD (UNIT) " 1 " INDOOR FAN MOTOR INDOOR (R.P.M. SIGNAL) FAN MOTOR FROM TERMINAL BOARD FROM FROM FROM (UNIT) " N " LOUVER LOUVER THERMISTOR (LOWER) (UPPER) Fig. L-4 Printed Wiring Diagram for AH-A07BE/A07BE-C/A09BE/A09BE-C/A12BE...
  • Page 17: Functions

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE FUNCTIONS AH-A07BE/A07BE-C/A09BE/A09BE-C/A12BE HEAT operation are noty provided with the heating function In the “HEAT” mode, the thermostat circuit is controlled by six thermostat lines (H01 thru 1. Temperature control characteristic H4). COOL operation In the “COOL” mode, the thermostat circuit is 37.0...
  • Page 18 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE DRY operation Table Y-1 On the switch on, the compressor always starts Compressor Fan speed to operate for 2 minutes with fan speed “DL” . The microcomputer reads the room temperature Cooling zone "DH" 2 minutes after this first compressor operation.
  • Page 19 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE 4. Hot-Keep 6. Overheating protection system This function automatically controls the on-off operation When overloading occurs during the heating operation, of the indoor fan motor in accordance during the this system controls the outdoor fan motor according to...
  • Page 20 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE 7. Current control Defrost start 60sec. 60sec. This system, in order to prevent overcurrent during heating operation, controls the outdoor fan motor and Compressor changes the indoor fan motor speed by detecting total MAX. 8min. (AY-A07BE/A07BE) current.
  • Page 21 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE 13. Automatic air conditioning 15. Outputs in each operation mode When automatic air conditioning is selected, the operation mode and preset temperature are set Table Y-5 automatically according to the room temperature on starting operation. Compressor Outdoor...
  • Page 22 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE 19.Diagnosis procedure When indoor fan motor is out of order or compressor lock occurs, the compressor, indoor fan motor, outdoor fan motor, and louver are all stopped and the operation LED(red) turns on or off syncronously with the timimg of the timer LED.
  • Page 23 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE Table Y-6 [AY-A07BE/A07BE-C/A09BE/A09BE-C/A12BE] S t e p R E D FLICK O F F O F F O F F O F F O F F O F F Y E L L O W O F F...
  • Page 24 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE Table Y-7 [AH-A07BE/A07BE-C/A09BE/A09BE-C/A12BE] Step FLICK OFF OFF OFF YELLOW Lamps FAN SOFT FAN LOW OFF OFF OFF OFF OFF FAN HIGH OFF OFF OFF OFF OFF AH-A07BE AUTO AH-A07BE-C OPEN Louver OFF CLOSE OFF OFF OFF OFF OFF...
  • Page 25 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE TROUBLESHOOTING GUIDE OF CONTROL CIRCUIT The machine does not function at all with remote controller and switches on the indoor unit. Using a tester, measure the measure the secondary voltage voltage between anodes of D1 of transformer.
  • Page 26 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE The machine does not function with remote controller Push butt "OI" on on the wireless remote controller. Is transmitting Are batteries of the indicator of the remote wireless remote controller controller active ? proper ? Replace the batteries with new ones.
  • Page 27 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE The room is not cooled at all or not cooled. The compressor does not operate. Fig. 1 Temperature properties of indoor thermistors Room temperature Heat exchange thermistor TH1 thermistor TH2 Thermistor Color Connector Push the button "AUX." on...
  • Page 28 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE The room is not heated at all or not heated. The compressor does not operate. Select HEAT MODE with remote controller. And then start operation. Push the button of "TEST RUN" on the indoor unit, and wait 3 minutes.
  • Page 29: Refrigeration Cycle

    Flare coupling Flare coupling 3-way 2-way valve valve Outdoor unit Capillary tube Silencer Compressor Condenser Accumulator Figure R-1. Refrigeration Cycle for AH-A07BE/A07BE-C/A09BE/A09BE-C/A12BE Indoor unit Indoor unit Evaporator Evaporator Flare coupling Flare coupling Flare coupling Flare coupling 3-way 2-way 3-way 2-way...
  • Page 30 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE Standard conditions: AH-A07BE / AH-A07BE-C / AH-A09BE / AH-A09BE-C / AH-A12BE REFRIGERANT PIPE LENGTH 7.5m Indoor side Outdoor side Dry-bulb Temp. (˚C) Relative Humidity (%) Dry-bulb Temp. (˚C) Relative Humidity (%) Cooling Temperature at each part and pressure in 3-way valve...
  • Page 31: Performance Curve

    2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front" 3) Indoor air temp. : Cooling 27˚C, Heating 20˚C 4) Power source : 220V, 50Hz Outside air temp.(˚C) Outside air temp.(˚C) Figure P-1. At Cooling for AH-A07BE/A07BE-C Figure P-2. At Cooling for AH-A09BE/A09BE-C 1200 1100 1000 Outside air temp.(˚C)
  • Page 32 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE Outside air temp.(˚C) Outside air temp.(˚C) Figure P-7. At Heating for AY-A07BE/A07BE-C Figure P-8. At Heating for AY-A09BE/A09BE-C 1200 1100 1000 Outside air temp.(˚C) Figure P-9. At Heating for AY-A12BE...
  • Page 33: Disassembling Procedure

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE DISASSEMBLING PROCEDURE FOR INDOOR UNIT SERVICING CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY 1. Open the opne panel, and remove 2 air filters. 5. Pull the front panel up. 2. Remove 4 screws fixing the front panel.
  • Page 34 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE 9. Remove the thermostat of the evaporator. 13. Remove the screw fixing the pipe holder. 10. Remove 4 connectors. 14. Remove 3 screws fixing the control box, and remove the control box. 11. Remove the thermistor holder from the evaporator.
  • Page 35 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE 17. Remove the drain cover from the evaporator. Note: During reassembly, verify that the dew on the pipe is led to the drain pan. 20. Remove 2 screws fixing the motor cover, and pull up the fan.
  • Page 36 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE How to remove the display cover 1. Push the center of display cover from the back. 2. Slide the display cover to the right. 2. Remove the screw fixing the terminal board. How to assemble the display cover 1.
  • Page 37 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE Drain pan and related 1. Remove 3 screws fixing motors. Drain Hose Drain pan Projection Groove To disconned To reconnect 2. Turn the cap area of the drain hose counterclockwise, and remove it from the drain pan.
  • Page 38 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE FOR OUTDOOR UNIT [AU-A09BE/A09BE-C/A12BE, AE-A09BE/A09BE-C/A12BE] SERVICING CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY Right side view Left side view 1. Loose a screw fixing the side cover. Front view 2. Loose a screw fixing the cord clamp.
  • Page 39 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE DISASSEMBLING PROCEDURE OF THE FAN Loose 8. Remove the terminal cover. 1. Loose the fan nut and fan can take out. 9. Remove 3 terminals. 2. Fan motor is secured by 4 screws. 10. Loose 4 screws fixing the control box.
  • Page 40 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE FOR OUTDOOR UNIT MODEL AE-A07BE/A07BE-C AND AU-A07BE/A07BE-C CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING 1 Remove the four (4) screws holding the terminal 3 Remove the another screws holding the cabinet cover and right side cover. Then take them out.
  • Page 41 2- 7 HPNLCA777JBEA Control panel 2- 8 PCOV-A618JBFA LED holder 2- 9 PCOV-A640JBFA LED holder B 2-10 DPWBFA212JBKZ Control board unit [AH-A07BE/A07BE-C] 2-10 DPWBFA209JBKZ Control board unit [AH-A09BE/A09BE-C] 2-10 DPWBFA213JBKZ Electric control board [AH-A12BE] 2-10 DPWBFA210JBKZ Control board unit [AY-A07BE/A07BE-C] 2-10...
  • Page 42 Fuse 3A 250V 2-19 RH-IXA664JBZZ Microcomputer (IC1) 2-29 RH-IZA149JBE0 Integrated circuit (IC2) 2-21 RIC--A022BDE0 Integrated circuit (IC3) 2-22 RIC--A025BDE0 Integrated circuit(IC4,IC5) [AH-A07BE/A07BE-C/A09BE/A09BE-C/A12BE] 2-23 VHIBR24C01A-6 PROM (IC6) 2-24 RH-IZA140JBE0 Integrated circuit (IC7) 2-25 RH-VZA020JBE0 Varistor (CNR1,CNR2.CNR3)[AY-A07BE/A07BE-C/A09BE/A09BE-C/A12BE] 2-25 RH-VZA020JBE0 Varistor (CNR3) [AH-A07BE/A07BE-C/A09BE/A09BE-C/A12BE]...
  • Page 43 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE INDOOR UNIT FOR AH/AY-A07BE/A07BE-C/A09BE/A09BE-C/A12BE 4-10 1-29 4-11 4-12 4-43 INVERTER AIR CONDITIONER 1-23 1-35 1-44 1-39 1-41 1-40 1-26 1-12 1-42 2-11 1-41 1-22 1-32 2-15 2-13 1-18 2-14 2-12 1-21 1-33 1-31 2-10 1-37 1-25...
  • Page 44 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE REPLACEMENT PARTS LIST [AU-A07BE/A07BE-C] REF. NO. PART NO. DESCRIPTION Q'TY CODE CABINET AND UNIT PARTS 1- 1 LBSHCA022JBF0 Bushing 1- 2 CMOTLA592JBE0 Fan motor 1- 3 NFANPA020JBEA Propeller fan 1- 4 PANGKA044JBY0 Motor angle ssembly 1- 5...
  • Page 45 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE REF. NO. PART NO. DESCRIPTION Q'TY CODE 3-14 LBND-A046JBE0 Wire fixing band [AU-A07BE-C] SCREWS, NUT AND WASHER 4- 1 LX-WZA019JBE0 Special washer 4- 2 LX-BZA078JBE0 Special screw 4- 3 LX-BZA075JBE0 Special screw 4- 4 LX-WZA019JBE0 Special washer...
  • Page 46 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE OUTDOOR UNIT FOR AU-A07BE/A07BE-C AU-A07BE-C 1-16 1-19 3-14 3-13 3-1-6 3-10 3-1-3 3-1-4 3-1-1 3-1-2 1-27 3-13 3-14 3-11 3-11 3-1-1 3-10 1-18 1-17 3-12 1-11 1-18 3-1-5 1-12 1-20 1-22 1-25 1-26 1-13 1-28 1-24...
  • Page 47 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE REPLACEMENT PARTS LIST [AE-A07BE/A07BE-C] REF. NO. PART NO. DESCRIPTION Q'TY CODE CABINET AND UNIT PARTS 1- 1 PSEL-A345JBE0 Cabinet seal 1- 2 CMOTLA592JBE0 Fan motor 1- 3 NFANPA020JBEA Propeller fan 1- 4 PANGKA018JBP0 Fan motor angle...
  • Page 48 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE REF. NO. PART NO. DESCRIPTION Q'TY CODE 3-13 PSRN-A040JBE0 Strainer 3-14 PGUMSA234JBE0 Damper rubber 3-15 PVLVXA030JBE0 Reverse valve 3-16 LX-NZA026JBE0 Special nut 3-17 PGUMSA033JBE0 Damper rubber SCREWS, NUT AND WASHER 4- 1 LX-WZA019JBE0 Special washer 4- 2...
  • Page 49 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE OUTDOOR UNIT FOR AE-A07BE/A07BE-C 1-16 3-1-6 1-16 3-1-3 3-15 3-1-4 1-27 3-1-2 3-17 3-11, 3-12 3-14 3-10 1-20 1-18 1-17 3-16 1-11 3-1-1 1-18 3-1-5 1-12 1-13 1-22 1-25 1-26 1-28 1-24 1-10 1-21 1-15 1-23...
  • Page 50: Replacement Parts List

    AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE REPLACEMENT PARTS LIST [AU-A09BE/A09BE-C/A12BE, AE-A09BE/A09BE-C/A12BE] REF. NO. PART NO. DESCRIPTION Q'TY CODE CABINET AND UNIT PARTS 1- 1 LBSHCA022JBE0 Bushing 1- 2 CMOTLA916JBEZ Fan motor [AU-A09BE/A09BE-C, AE-A09BE/A09BE-C] 1- 2 CMOTLA917JBEZ Fan motor [AU-A12BE, AE-A12BE] 1- 3...
  • Page 51 AH-A07BE-C/09BE-C AH-A07BE/09BE/12BE AY-A07BE-C/09BE-C AY-A07BE/09BE/12BE REF. NO. PART NO. DESCRIPTION Q'TY CODE 2- 7 LBNDKA062JBW0 Capacitor clamp 2- 8 PBOX-A350JBWZ Control box 2- 9 CCIL-A098JBEZ Coil [AE-A09BE/A12BE] 2-10 RHOG-A185JBEZ Overload relay [AU-A09BE, AE-A09BE] CYCLE PARTS 3- 1 FCMPRA104JBKZ Compressor ass'y [AU-A09BE, AE-A09BE]...
  • Page 52 4-5 4-6 1-26 1-10 1-15 1-25 1-34 3-10 1-30 AU-A09BE/A12BE 3-1-6 3-1-6 3-1-4 3-1-4 3-1-2 3-1-2 3-1-3 2-10 3-1-3 1-14 1-33 1-31 2-10 3-10 1-32 1-35 3-11 3-1-5 3-12 1-16 1-21 1-12 1-17 '02 SHARP CORP. (4U1.00E) Printed in Netherlands...

Table of Contents