Dx2010 Address Programming; Table 9: Dx2010 Address 106; Table 10: Dx2010 Address 107 (For D6412 Only); Figure 20: Dx2010 Sensor Loop Wiring, Single Loop Configuration - Bosch D6412 Operation And Installation Manual

Hide thumbs Also See for D6412:
Table of Contents
8.2.6. 1 DX2010 Standard Sensor Loop Wiring
The single loop configuration for DX2010 standard sensor loop wiring is shown in Figure 20.
8.2.6.2 DX2010 Doubled Sensor Loop (Point) Wiring
The doubled loop configuration for DX2010 sensor loop wiring is shown in Figure 21.
Open for alarm
otherwise
Normally Closed
3.65K Ω

Figure 21: DX2010 Sensor Loop Wiring, Doubled Loop Configuration

Tables 9 and Table 10 identify the 106 and 107 DX2010 sensor loop addresses, respectively.
8.2.7

DX2010 Address Programming

Each DX2010 module connected to the panel must have its address jumpers set to the addresses. These address settings are
listed in Table 11.
© 2003 Bosch Security Systems
1
COM
2
3
COM
Use 2.21 K EOL

Figure 20: DX2010 Sensor Loop Wiring, Single Loop Configuration

Common
DX2010 Inputs
(See Table 7)
Each loop is monitored
as a separate point.
EOL
1
2
3.65 K
9
10
2.2 K
17
18

Table 9: DX2010 Address 106

EOL
1
2
3.65 K
25
26
2.2 K
33
34

Table 10: DX2010 Address 107 (for D6412 only)

D6412/D4412 Operation and Installation Guide
Off-Board Sensors Loops
4
5
COM
6
7
COM
8
Input
Terminals
1 to 8
DX2010 Inputs
(See Tables 7 and 8)
DX2010 Sensor Loop
3
4
5
6
7
11
12
13
14
15
19
20
21
22
23
DX2010 Sensor Loop
3
4
5
6
7
27
28
29
30
31
35
36
37
38
39
Page 37
D6412/D4412
Open for alarm
otherwise
Normally Closed
2.2K Ω
8
16
24
8
32
40
45349E