Wiring Diagram - Mitsubishi Electric MJ-E14CG-S1-IT Service Manual

Table of Contents

5. Wiring Diagram

1) Wiring Diagram
Blue
Brown
Power plug
Gray
Run capacitor
Gray
Safety Devices
(1) Current fuse ....................Overcurrent flow caused by deterioration in electrical parts or other problems
(2) Motor protector................The compressor stops operating if the room temperature exceeds 35°C.
(Overload relay)
(3) Control circuitry ...............The room temperature thermister senses temperature below about 0°C, and
(4) Thermal fuse ...................When blower motor temperature exceeds 133°C due to blower locking or other
(5) Current fuse for compressor protection
6
C
R
CM
FM
S
P5
P2
P1
Power control board
P4
turns the power source to OFF.
The compressor will also shut down when malfunctions or other problems
cause the current flow to exceed 5.3A.
shuts down the compressor.
malfunctions, blower operation shuts down.
................... If the protection by motor protector and control circuitry is not effective,
the compressor shuts down when the current to it exceeds approximately 10A.
SV
Operation
control board
P200
P201
P3
P100
P101
P10
P11
P20
P13
Sensors
(Humidity and room
temperature sensing)
1℃ (defrost)/12℃ (end)
White
White
SM
Stepping motor
Gray
Float switch
Gray
Thermistor (Tube
temperature sensing)