Pci Riser; Internal Core I/O; External Core I/O; Power Supply Unit - HP 9000 rp3410 User's & Service Manual

Hide thumbs Also See for 9000 rp3410:
Table of Contents
Total memory bandwidth is 8.5 GB/s, split across two 4.25 GB/s memory buses.
Open page memory latency is 80 nanoseconds.

PCI Riser

Two (HP 9000 rp3410 server) or four (HP 9000 rp3440 server) independent PCI-X 133 MHz 64-bit 3.3V 15W
slots. No 5V card and hot-pluggable support.

Internal Core I/O

The following is supported on the HP 9000 rp3410 and rp3440 servers:
Dual-channel SCSI U160 interface, two internal 68-pin connectors, one 68-pin external connector.
SCSI backplane configured either as two channels with 2+1 drives. A SAF-TE accessory (currently not
available) is required to configure the SCSI backplane as one channel with three drives.
Three internal SCSI drive connectors are of the 80-pin type and provide drive electrical hot-pluggable
capability.
SCSI backplane is designed to support a SCSI management piggy board accessory that provides a SCSI
management SAF-TE chip and shunts the backplane's channels A and B to provide three disks on
channel A and leave only the external connector on channel B.
One internal IDE connector for a slim-line optical device (CD and DVD).
No floppy connector.

External Core I/O

The following is supported on the HP 9000 rp3410 and rp3440 servers:
One SCSI U160 68-pin connector.
One 10/100/1000Base-T Ethernet LAN connectors for copper cable.
Four USB 2.0 ports.
Three DB-9 ports (console, UPS, and modem) through a 3-connector M cable.

Power Supply Unit

The following is supported on the HP 9000 rp3410 and rp3440 servers:
650W output power.
The power supply is split in a front end block (the actual power supply case) that converts the line voltage
into a high dc voltage and back end voltage regulation modules (on the motherboard) that step down the
front end dc voltage to the required voltages.
Redundant and hot-pluggable power supplies (front end block only).

System Board Manageability

The following is supported on the HP 9000 rp3410 and rp3440 servers:
Baseboard Management Controller (BMC).
Temperature monitoring and fans regulation by BMC.
Chapter 1
Overview
Detailed Server Description
23
Table of Contents
loading

This manual is also suitable for:

9000 rp3440

Table of Contents