Abstract
This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware components and
software. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment, trained in
recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 675780-004
January 2014
Edition: 4
Table of Contents
loading

Summary of Contents for HP ProLiant DL360e Gen8

  • Page 1 This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware components and software. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment, trained in recognizing hazards in products, and are familiar with weight and stability precautions.
  • Page 2 © Copyright 2012, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3: Table Of Contents

    Contents Customer self repair ........................6 Parts only warranty service ..........................6 Illustrated parts catalog ....................... 16 Mechanical components ..........................16 System components ............................ 19 Removal and replacement procedures ................... 26 Required tools ............................26 Safety considerations ..........................26 Preventing electrostatic discharge ...................... 26 Symbols on equipment ........................
  • Page 4 Power supply specifications ......................... 91 HP 460 W CS Gold Hot-plug Power Supply (92% efficiency) ............... 92 HP 460 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) ............ 92 HP 750 W CS Gold Hot-plug Power Supply (92% efficiency) ............... 93 HP 750 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) ............
  • Page 5 HP 750 W CS Titanium Hot-plug Power Supply (96% efficiency) ............93 HP 750 W CS -48 V DC Hot-plug Power Supply (94% efficiency) ............94 HP 1200 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) ..........95 Hot-plug power supply calculations ......................95 Acronyms and abbreviations ......................
  • Page 6: Customer Self Repair

    HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days. The defective part must be returned with the associated documentation in the provided shipping material.
  • Page 7 HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione.
  • Page 8 La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.
  • Page 9 Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:...
  • Page 10 HP podrá cobrarle por el de sustitución. En el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.
  • Page 11 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
  • Page 12 No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. Customer self repair 12...
  • Page 13 Customer self repair 13...
  • Page 14 Customer self repair 14...
  • Page 15 Customer self repair 15...
  • Page 16: Illustrated Parts Catalog

    Illustrated parts catalog Mechanical components Item Description Spare part Customer self number repair (on page 6) Access panel 684957-001 Mandatory Hardware blank kit 684958-001 Optional a) Heatsink blank — — b) Fan blank — — c) Optical drive blank — —...
  • Page 17 Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
  • Page 18 Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
  • Page 19: System Components

    System components Item Description Spare part Customer self number repair (on page 6) System board assemblies (include alcohol pad and thermal — — compound) System board assembly for Intel Xeon E5-2400 processors 684956-001 Optional a) System board with subpan — —...
  • Page 20 Item Description Spare part Customer self number repair (on page 6) f) Processor baffle, left* — — g) Processor baffle, middle* — — h) Power supply baffle* — — PCIe riser boards — — a) PCIe riser board without SAS support* 685184-001 Mandatory b) PCIe riser board with SAS support*, †...
  • Page 21 Item Description Spare part Customer self number repair (on page 6) a) 2 GB, single-rank, x8, PC3-12800E-11 684033-001 Mandatory b) 2 GB, single-rank x8 PC3L-10600E-9* 664694-001 Mandatory c) 2 GB, single-rank x8 PC3L-12800E-11* 715279-001 Mandatory d) 4 GB, single-rank x4 PC3-12800R-11* 664689-001 Mandatory e) 4 GB, single-rank x4 PC3L-10600R-9*...
  • Page 22 Item Description Spare part Customer self number repair (on page 6) f) 240-GB EV solid state drive* 718294-001 Mandatory g) 400-GB MLC EM solid state drive* 653970-001 Mandatory h) 480-GB EV solid state drive* 718296-001 Mandatory i) 500-GB MDL hard drive* 658103-001 Mandatory j) 600-GB EV solid state drive*...
  • Page 23 SATA DVD-RW drive* 652297-001 Mandatory Power supplies — — a) HP 460 W CS Gold Hot-Plug Power Supply (92% efficiency) 511777-001 Mandatory b) HP 460 W CS Platinum Plus Hot-Plug Power Supply (94% 660184-001 Mandatory efficiency)* c) HP 750 W CS Gold Hot-Plug Power Supply (92%...
  • Page 24 505836-001 * Not shown ** All processors in this HP ProLiant server must have the same cache size, speed, number of cores, and rated maximum power consumption. † The HP Dynamic Smart Array B320i controller embedded in this riser board option requires an HP Smart Array SAS License Key to support SAS drives.
  • Page 25 Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
  • Page 26: Removal And Replacement Procedures

    T-25 Torx screwdriver (for screws located inside the front panel quick-release levers) • T-10/T-15 Torx screwdriver • HP Insight Diagnostics (on page 70) Safety considerations Before performing service procedures, review all the safety information. Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts.
  • Page 27: Server Warnings And Cautions

    Get help to lift and stabilize the product during installation or removal, especially when the • product is not fastened to the rails. HP recommends that a minimum of two people are required for all rack server installations. A third person may be required to help align the server if the server is installed higher than chest level.
  • Page 28: Rack Warnings

    Extend the server from the rack (on page 30). If you are performing service procedures in an HP, Compaq branded, Telco, or third-party rack cabinet, you can use the locking feature of the rack rails to support the server and gain access to internal components.
  • Page 29: Remove The Security Bezel (Optional)

    Remove the security bezel (optional) To access the front panel components, unlock and then remove the security bezel. Power down the server Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and programs. WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server.
  • Page 30: Extend The Server From The Rack

    If using a friction rail system, to perform installations or maintenance that requires access panel • removal, remove the server from the rack. To extend the server from an HP, Compaq-branded, Telco, or third-party rack: Power down the server (on page 29). Remove all power: Disconnect each power cord from the power source.
  • Page 31: Remove The Server From The Rack

    To access the server rear panel: Release the cable management arm. Open the cable management arm. The cable management arm can be right-mounted or left-mounted. Remove the server from the rack Removal and replacement procedures 31...
  • Page 32: Front Video Adapter

    Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. HP recommends that a minimum of two people are required for all rack server installations. A third person may be required to help align the server if the server is installed higher than chest level.
  • Page 33: Drive Blank

    CAUTION: Be sure to connect the video adapter to the video connector, and not to the USB connector. To replace the component, reverse the removal procedure. Drive blank CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
  • Page 34: Power Supply Blank

    To replace the component, reverse the removal procedure. Power supply blank CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. To remove the component: Access the rear panel ("Access the product rear panel"...
  • Page 35: Access Panel

    Remove the power supply. To replace the component, reverse the removal procedure. Access panel To remove the component: WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: Do not operate the server for long periods with the access panel open or removed.
  • Page 36: Optical Drive

    Remove the optical drive blank Retain the blank for future use. To replace the component, reverse the removal procedure. Optical drive CAUTION: To prevent improper cooling and thermal damage, do not operate the chassis unless all bays are populated with a component or a blank. To remove the component: Power down the server (on page 29).
  • Page 37 Four-bay LFF drive model Eight-bay SFF drive model Disconnect the optical drive cable from the drive. To replace the component, reverse the removal procedure. Removal and replacement procedures 37...
  • Page 38: Drive Cage Assembly

    Drive cage assembly The drive cage assembly includes the drive cage with backplane and the front panel assembly. To remove the component: Power down the server (on page 29). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server.
  • Page 39: Hot-Plug Fan Blank And Module

    Do one of the following: Extend the server from the rack (on page 30). Remove the server from the rack (on page 31). Remove the access panel ("Access panel" on page 35). Remove the air baffles: Processor baffles Power supply baffle To replace the component, reverse the removal procedure.
  • Page 40: Fan Population Guidelines

    Fan population guidelines • In a single-processor, nonredundant configuration, fans 5, 6, 7, and 8 cool the server. To enable the redundant fan mode, install a new fan in the fan bay 1. • In a dual-processor configuration, nonrendundant fan mode is not supported; all eight fans are required.
  • Page 41: Removing A Hot-Plug Fan Blank Or Module If The Server Is Installed In A Friction Rail System

    Do one of the following: Remove the fan blank. Remove the fan module. To replace the component, reverse the removal procedure. If the fan replacement is intended to upgrade the server from a nonredundant to a redundant fan mode, reboot the server after fan installation. Removing a hot-plug fan blank or module if the server is installed in a friction rail system Power down the server (on page 29).
  • Page 42 Disconnect each power cord from the server. Remove the server from the rack (on page 31). Remove the access panel ("Access panel" on page 35). Do one of the following: Remove the fan blank. Remove the fan module. CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
  • Page 43: Dimms

    DIMMs To remove the component: Power down the server (on page 29). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Do one of the following: Extend the server from the rack (on page 30). Remove the server from the rack (on page 31).
  • Page 44: Heatsink

    Remove the server from the rack (on page 31). Remove the access panel ("Access panel" on page 35). Remove the heatsink blank. To replace the component, reverse the removal procedure. Heatsink To remove the component: Power down the server (on page 29). Remove all power: Disconnect each power cord from the power source.
  • Page 45 Remove the heatsink from the processor backplate. To replace the component: Clean the old thermal grease from the processor with the alcohol swab. Allow the alcohol to evaporate before continuing. Remove the thermal interface protective cover from the heatsink. Install the heatsink: Position the heatsink using the guide pin on the processor backplate.
  • Page 46: Processor

    Finish the installation by completely tightening the screws in the same sequence. Install the access panel. Do one of the following: Slide the server into the rack. Install the server into the rack. Connect each power cord to the server. Connect each power cord to the power source.
  • Page 47 IMPORTANT: Processor socket 1 must be populated at all times or the server does not function. In a multiprocessor configuration, to optimize system performance, HP recommends balancing the total capacity of the DIMMs across the processors. To remove the component: Power down the server (on page 29).
  • Page 48 Remove the processor from the processor retaining bracket. CAUTION: To avoid damage to the processor, do not touch the bottom of the processor, especially the contact area. To replace the component: Install the processor. Verify that the processor is fully seated in the processor retaining bracket by visually inspecting the processor installation guides on either side of the processor.
  • Page 49 CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board, do not touch the processor or the processor socket contacts. Close the processor retaining bracket. When the processor is installed properly inside the processor retaining bracket, the processor retaining bracket clears the flange on the front of the socket.
  • Page 50: Pci Riser Cage

    Install the heatsink: Position the heatsink using the guide pin on the processor backplate. Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws. Finish the installation by completely tightening the screws in the same sequence. Install the access panel.
  • Page 51: Expansion Board

    Lift the release tabs, and then rotate them 180° counterclockwise. Lift the PCI riser cage to unseat the riser boards. To replace the component, reverse the removal procedure. Expansion board To remove the component: Power down the server (on page 29). Remove all power: Disconnect each power cord from the power source.
  • Page 52: Pcie Riser Board

    To replace the component, reverse the removal procedure. PCIe riser board To remove the component: Power down the server (on page 29). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Do one of the following: Extend the server from the rack (on page 30).
  • Page 53: Flash-Backed Write Cache Procedures

    Flash-backed write cache procedures The following types of procedures are provided for the FBWC option: • Removal and replacement of failed components: Removing the cache module ("FBWC module" on page 53) Removing the capacitor pack ("Capacitor pack" on page 55) Removing the capacitor pack holder ("Capacitor pack holder"...
  • Page 54 Disconnect the capacitor pack cable from the cache module. Remove the cache module: Cache module on the system board Cache module on a storage controller To replace the component, reverse the removal procedure. Removal and replacement procedures 54...
  • Page 55: Capacitor Pack

    Capacitor pack CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up. To remove the component: Power down the server (on page 29).
  • Page 56: Capacitor Pack Holder

    Remove the capacitor pack. To replace the component, reverse the removal procedure. Capacitor pack holder To remove the component: Power down the server (on page 29). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Do one of the following: Extend the server from the rack (on page 30).
  • Page 57: Recovering Data From The Flash-Backed Write Cache

    Set up a recovery server using an identical server model. Do not install any internal drives or FBWC in this server. (HP recommends this option.) Find a server that has enough empty drive bays to accommodate all the drives from the failed server and that meets all the other requirements for drive and array migration.
  • Page 58: System Battery

    Power down the failed server ("Power down the server" on page 29). Transfer the drives from the failed server to the recovery server. Perform one of the following: If the array controller has failed, remove the cache module and capacitor pack from the failed array controller, and install the cache module and capacitor pack on an identical array controller model in the recovery server.
  • Page 59: System Board Assembly Procedures

    Re-enter the server serial number and the product ID ("Re-entering the server serial number and product ID" on page 66). • Reactivate the HP Smart Array SAS license key (on page 67). Install the spare system board CAUTION: To avoid ESD damage, when removing electrostatic-sensitive components from the failed system board, place the components on a static-dissipating work surface or inside separate antistatic bags.
  • Page 60 Extend the server from the rack (on page 30). Remove the server from the rack (on page 31). Remove the access panel ("Access panel" on page 35). Remove the fans ("Hot-plug fan blank and module" on page 39). Remove the PCI riser cage ("PCI riser cage"...
  • Page 61 CAUTION: When returning a damaged system board to HP, always install all processor socket covers to prevent damage to the processor sockets and system board. If the FBWC module is installed on the system board, remove the module ("FBWC...
  • Page 62 Use the tray handles to lift the system board out of the chassis. To replace the system board assembly: Install the system board assembly. Removal and replacement procedures 62...
  • Page 63 Open each of the processor locking levers in the order indicated, and then open the processor retaining bracket. Remove the clear processor socket cover. Retain the processor socket cover for future use. Removal and replacement procedures 63...
  • Page 64 Install the processor. Verify that the processor is fully seated in the processor retaining bracket by visually inspecting the processor installation guides on either side of the processor. THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED.
  • Page 65 Press and hold the processor retaining bracket in place, and then close each processor locking lever. Press only in the area indicated on the processor retaining bracket. Install the processor socket cover onto the processor socket of the failed system board. Clean the old thermal grease from the heatsink and the top of the processor with the alcohol swab.
  • Page 66: Re-Entering The Server Serial Number And Product Id

    Finish the installation by completely tightening the screws in the same sequence. Install the fans. Install all components removed from the failed system board. Connect all cables disconnected from the failed system board. Install the PCI riser cage. Install the access panel. Do one of the following: Slide the server into the rack.
  • Page 67: Reactivate The Hp Smart Array Sas License Key

    During POST, the system recognizes devices. When the system recognizes a Smart Array controller, press F5. The system launches the HP SSA GUI, or if you are using Serial Console, the system launches the HP SSA CLI. To launch HP SSA using HP Intelligent Provisioning: Boot the server.
  • Page 68: Hp Trusted Platform Module

    If you suspect a TPM board failure, leave the TPM installed and remove the system board. Contact an HP authorized service provider for a replacement system board and TPM board.
  • Page 69: Troubleshooting

    • Simplified Chinese (http://www.hp.com/support/ProLiant_TSG_v1_sc) The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the guide, select a language: •...
  • Page 70: Diagnostic Tools

    HP strongly recommends that you install HP Insight Remote Support software to complete the installation or upgrade of your product and to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or HP contractual support agreement. HP Insight Remote Support supplements your monitoring continuously to...
  • Page 71: Hp Rom-Based Setup Utility

    Configuring memory options • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP RBSU Information Library (http://www.hp.com/go/rbsu/docs). Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.
  • Page 72: Internal Usb Functionality

    ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND (does not apply to HP ProLiant DL980 Servers), or panic. A system fail-safe timer, the ASR timer, starts when the System Management driver, also known as the Health Driver, is loaded. When the operating system is functioning properly, the system periodically resets the timer.
  • Page 73: Component Identification

    Component identification Front panel components • Four-bay LFF drive model Item Description Optical drive (optional) Serial number/iLO information pull tab* Front video connector (front video adapter, part number 655915-B21 required) USB 2.0 connectors LFF drives (8.89 cm, 3.5 in) *The serial number/iLO information pull tab is double-sided. The top side shows the server serial number, and the reverse side shows the default iLO account information.
  • Page 74: Front Panel Leds And Buttons

    Front panel LEDs and buttons Item Description Status UID button/LED Solid blue = Activated Flashing blue (1 Hz/cycle per sec) = Remote management or firmware upgrade in progress Off = Deactivated Power On/Standby button Solid green = System on and system power LED Flashing green (1 Hz/cycle per sec) = Performing power on sequence Solid amber = System in standby Off = No power present*...
  • Page 75: Rear Panel Components

    Rear panel components Item Description Slot 1 PCIe3 x16 (16, 8, 4, 1)* Slot 2 PCIe2 x8 (4,1)* Power supply 2 Power supply 1 NIC connectors (4 to 1) Serial connector Video connector USB connectors iLO connector * For more information on the riser board slots supported by the onboard PCI riser connectors, see "PCIe riser board slot definitions (on page 76)."...
  • Page 76: Pcie Riser Board Slot Definitions

    Item Description Status Power supply LED Green = Normal Off = One or more of the following conditions exists: • Power is unavailable • Power supply failed • Power supply is in standby mode • Power supply error PCIe riser board slot definitions Slot Riser board Type...
  • Page 77 Item Description Cache module connector TPM connector Mini-SAS connector System battery SATA drive connector SATA optical/storage drive connector Front panel connectors Processor socket 1 GPU power connector Fan connector 8 Fan connector 7 Fan connector 6 Fan connector 5 Fan connector 4 Internal USB connector Fan connector 3 Fan connector 2...
  • Page 78: Dimm Slot Locations

    DIMM slot locations DIMM slots are numbered sequentially (1 through 6) for each processor. The supported AMP modes use the letter assignments for population guidelines. System maintenance switch Switch Default Function Off = No function On = iLO 4 security is disabled Off = System configuration can be changed On = System configuration is locked...
  • Page 79: Drive Numbering

    • Use the iLO Virtual NMI feature. • Short the NMI header ("System board components" on page 76). For more information, see the HP website (http://www.hp.com/support/NMI). Drive numbering • Four-bay LFF drive model • Eight-bay SFF drive model When the two-port SATA cable is installed in the eight-bay drive cage, the server supports the six-drive SATA configuration.
  • Page 80: Fbwc Module Led Definitions

    Item Status Definition Flashing green The drive is rebuilding or performing a RAID migration, stripe size migration, capacity expansion, or logical drive extension, or is erasing. Flashing The drive is a member of one or more logical drives and predicts amber/green the drive will fail.
  • Page 81 • Cache module installed on the system board 1 - Amber 2 - Green 3 - Green Interpretation The cache module is not powered. Flashing 0.5 Hz Flashing 0.5 Hz The cache microcontroller is executing from within its boot loader and receiving new flash code from the host controller.
  • Page 82: Fan Locations

    Fan locations Component identification 82...
  • Page 83: Cabling

    For information on cabling peripheral components, refer to the white paper on high-density deployment at the HP website (http://www.hp.com/products/servers/platforms). CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.
  • Page 84: Four-Bay Lff Drive Cabling

    Four-bay LFF drive cabling • Four-bay LFF drive cage connected to the system board Item Description Power cable Capacitor pack cable 560 mm Mini-SAS cable • Four-bay LFF drive cage connected to the SAS-enabled riser board Item Description Power cable Capacitor pack cable 560 mm Mini-SAS cable Cabling 84...
  • Page 85 • Four-bay LFF drive cage connected to a controller in the full-height expansion slot Item Description Power cable Capacitor pack cable 800 mm Mini SAS cable for the H220 and P420 controllers 890 mm Mini-SAS cable for the H222 and P222 controllers •...
  • Page 86: Eight-Bay Sff Drive Cabling

    Eight-bay SFF drive cabling • Six-drive SFF SATA configuration Item Description Power cable Capacitor pack cable Two-port SATA cable 700 mm Mini-SAS cable • Eight-bay SFF drive cage connected to the SAS-enabled riser board Item Description Power cable Capacitor pack cable 560 mm Mini-SAS cable Cabling 86...
  • Page 87 Item Description 700 mm Mini-SAS cable • Eight-bay SFF drive cage connected to the P822 controller in the full-height expansion slot Item Description Power cable Capacitor pack cable 615 mm Mini-SAS cable 800 mm Mini-SAS cable • Eight-bay SFF drive cage connected to the P420 controller in the full-height expansion slot Item Description Power cable...
  • Page 88 • Eight-bay SFF drive cage connected to the P420 controller in low-profile expansion slot Item Description Power cable Capacitor pack cable 615 mm Mini-SAS cable 800 mm Mini-SAS cable • Eight-bay SFF drive cage connected to the P430 controller in the full-height expansion slot Item Description Power cable...
  • Page 89: Optical Drive Cabling

    • Eight-bay SFF drive cage connected to the P430 controller in the low-profile expansion slot Item Description Power cable Capacitor pack cable Mini-SAS Y-cable Optical drive cabling • Optical drive cabling in the four-bay LFF drive cage Cabling 89...
  • Page 90: Gpu Power Cabling

    • Optical drive cabling in the eight-bay SFF drive cage GPU power cabling Cabling 90...
  • Page 91: Specifications

    HP 750 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) • HP 750 W CS Titanium Hot-plug Power Supply (96% efficiency) • HP 750 W CS -48 V DC Hot-plug Power Supply (94% efficiency) • HP 1200 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) Specifications 91...
  • Page 92: Hp 460 W Cs Gold Hot-Plug Power Supply (92% Efficiency)

    CAUTION: Check the system and power supply input ratings before powering up the server. HP 460 W CS Gold Hot-plug Power Supply (92% efficiency) Specification Value — Input requirements 100 V AC to 240 V AC Rated input voltage 50 Hz or 60 Hz...
  • Page 93: Hp 750 W Cs Gold Hot-Plug Power Supply (92% Efficiency)

    HP 750 W CS Gold Hot-plug Power Supply (92% efficiency) Specification Value — Input requirements 100 V AC to 240 V AC Rated input voltage 50 Hz to 60 Hz Rated input frequency 9 A to 4.5 A Rated input current...
  • Page 94: Hp 750 W Cs -48 V Dc Hot-Plug Power Supply (94% Efficiency)

    750 W at 200 V to 240 V AC input Rated steady-state power 750 W at 200 V to 240 V AC input Maximum peak power HP 750 W CS -48 V DC Hot-plug Power Supply (94% efficiency) Specification Value —...
  • Page 95: Hp 1200 W Cs Platinum Plus Hot-Plug Power Supply (94% Efficiency)

    (60 V DC). The branch circuit overcurrent protection must be rated 24 A. • HP 1200 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) Specification Value —...
  • Page 96: Acronyms And Abbreviations

    Advanced Host Controller Interface Advanced Memory Protection Automatic Server Recovery Customer Self Repair double data rate enterprise mainstream (HP SSD endurance class) enterprise (HP Enterprise drive family) enterprise value (HP SSD endurance class) FBWC flash-backed write cache graphics processing unit...
  • Page 97 International Electrotechnical Commission Integrated Lights-Out Integrated Management Log large form factor LRDIMM load reduced dual in-line memory module midline (HP Midline drive family) multilevel cell (NAND memory type used in SSDs) nonmaskable interrupt NVRAM nonvolatile memory PCIe Peripheral Component Interconnect Express...
  • Page 98 ATA Secure Digital SELV separated extra low voltage small form factor single level cell (NAND memory type used in SSDs) HP Service Pack for ProLiant Trusted Platform Module UDIMM unregistered dual in-line memory module unit identification universal serial bus...
  • Page 99: Documentation Feedback

    Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback.
  • Page 100: Index

    98 drive blank 33 HP Insight Remote Support software 70 drive cabling 82 HP Smart Array SAS License Key 19, 59 drive LEDs 79 HP Systems Insight Manager (SIM) 70, 71 drive numbering 78 HP technical support 6...
  • Page 101 power supply blank 34 power supply specifications 90, 92 illustrated parts catalog 16 powering down 29 iLO connector 74 power-on password 78 Insight Diagnostics 70 processor air baffle 38 Integrated Lights-Out (iLO) 71 processors 46 Integrated Management Log (IML) 71 Product ID 66 internal USB connector 76 QuickSpecs 70...
  • Page 102 temperature requirements 90 TPM connector 76 troubleshooting resources 69 Trusted Platform Module (TPM) 68 UID button 74 UID LED 74 unit identification (UID) 74 USB connector 73, 74 USB support 71 utilities, deployment 71 video connector 73, 74 warnings 27, 28 weight 90 Index 102...

Table of Contents