Bp Unit - Daikin FTX25JVEA9 Service Manual

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents
Installation
1.2

BP Unit

1
• This unit may be installed suspended from the ceiling or mounted on the wall.
This unit may only be installed vertically, as shown in the diagram below.
However, it may be freely installed in any direction forward or back, and to the sides.
• Be sure to leave a
both ceiling-suspended installation and wall-mounted installation.
• This unit
"does not require drain treatment"
piping insulation.
• This unit may be installed with sides
• The piping for the indoor unit may be freely led around in directions
• The inclination of side
Three-sided view
(product dimensions and attachment bolt pitch)
3 - Brazing
2
X
58
58
(74)
62
Installation restrictions
(installation and service space)
Min 400
Be sure to leave a 600mm square
opening for service and maintenance.
346
INSTALLATION
600mm square
opening for service and inspection as shown in the diagram below, for
F
or
R
facing forward (servicing direction).
must be within ±5˚C degrees forward or back or to the sides.
D
O.D. ø15.9 CuT
I.D. ø6.4 CuT
100
Suspension bolt pitch
130
Suspension bolt pitch
Collective indication
Branch piping
label
Room A
Room B
Room C
( 130 )
( 75 )
Indication label
(for indoor unit)
Earth terminal(M4)
Wiring clamp
Min 400
(Servicing space)
Inspection opening
as it uses internal foam treatment as low-pressure
,
, or
I.D. ø9.5 CuT
I.D. ø19.1 CuT
431
40
Terminal
Main piping
Wiring clasps
( 40 )
400
570
Indication label
(for outdoor unit)
Standard accessories
4 For Branch piping ( Gas )
(Precaution)
60
Cut line for
DIMPLE
Cut line for I.D. ø15.9
I.D. ø9.5
Cut line for I.D. ø12.7
(Precaution) Cut the piping on the standard accessories
to match the indoor unit's piping diameter.
(Side
D
is facing up.)
.
Wall-mounted
D
F
R
( 57 )
60
50
2-Brazing
2 For Main piping ( Gas )
160
I.D. ø19.1
3 For Branch piping ( Liquid )
150
Cut line
I.D. ø9.5
Caution Before Operation
Si18-201

Hide quick links:

Table of Contents
loading

Table of Contents