Outdoor Unit High Pressure Value and Outdoor Total Electric Current Curve (Heating)
Model Name : ASU18RLF
[Condition]
Ambient
Indoor 59 °F, 68°F, 73.4°F , Outdoor 35.6 °F, 44.6°F, 53.6°F
temperature
(15 °C , 20 °C , 23 °C)
Refrigerant
Standard amount
amount
Piping
7.5m (Height difference 1m)
length
Power
60Hz - 230V
voltage
Operation
TEST mode (Heating), Hi Fan, Lower direction, Front air flow
condition
Measuring
outdoor unit overall current with the current clamp meter at Power Cable.
method
Caution
Start operation with the condition of the Indoor Unit air filter clean.
[Constant Frequency Operation Method (Test mode)]
1. Operate on Heating mode, and press TEST button of remote control.
2. Operate continuously for 30 minutes. (After 60 minutes of operation, Test mode is released automatically.)
(1) Indoor/Outdoor Temperature - Outdoor High Pressure Curve
ASU18RLF
3.4
3.2
3.0
2.8
2.6
2.4
2.2
2.0
32
41
(0)
(5)
Outdoor ambient temperature
(2) Indoor/Outdoor Temperature - Outdoor Total Electric Current Curve
ASU18RLF
10.0
73.4 °F( 23 ° C)
Indoor ambient
9.5
68 °F( 20 ° C)
temperature °F(° C)
59 °F( 15 ° C )
9.0
8.5
8.0
7.5
7.0
32
41
(0)
(5)
Outdoor ambient temperature
(2 °C , 7 °C , 12 °C)
73.4 °F( 23 ° C)
Indoor ambient
68 °F( 20 ° C)
temperature °F(° C)
59 °F( 15 ° C )
50
59
(10)
(15)
[60Hz-230V]
50
59
(10)
(15)
[60Hz-230V]
03-08
[ °F ]
( °C)
[ °F ]
( °C)