19.2.4. WH-SDF14C6E5 WH-UD14CE5-A
LWC
Tamb
-15
-7
2
7
25
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
19.2.5. WH-SDF16C6E5 WH-UD16CE5-A
LWC
Tamb
-15
-7
2
7
25
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
19.3. Hydraulic Pump Performance
30
35
HC
IP
HC
IP
9.90
3.91
9.50
4.05
11.10
3.73
10.70
4.08
12.90
3.51
12.40
3.73
14.00
2.60
14.00
3.11
14.00
1.75
14.00
2.10
30
35
HC
IP
HC
IP
10.60
4.13
10.30
4.42
11.90
4.07
11.40
4.47
13.50
3.78
13.00
4.00
16.00
3.25
16.00
3.78
16.00
2.35
16.00
2.73
40
45
HC
IP
HC
IP
9.00
4.19
8.60
4.33
10.20
4.43
9.80
4.78
11.90
3.95
11.40
4.17
14.00
3.63
14.00
4.14
14.00
2.45
14.00
2.80
40
45
HC
IP
HC
IP
10.00
4.71
9.70
5.00
10.80
4.87
10.30
5.26
12.40
4.22
11.90
4.44
16.00
4.31
16.00
4.84
16.00
3.11
16.00
3.49
135
50
55
HC
IP
HC
IP
7.90
4.45
7.30
4.56
9.10
4.76
8.50
4.74
10.40
4.29
9.50
4.40
13.60
4.61
13.30
5.08
14.00
3.05
14.00
3.44
50
55
HC
IP
HC
IP
8.80
4.98
7.90
4.95
9.60
5.13
9.00
4.99
10.80
4.50
9.80
4.55
15.20
5.15
14.50
5.45
16.00
3.71
15.90
3.93