20.5 cubic feet upright type with automatic defrost (1 page)
Summary of Contents for GE FUF14SVRWW
Page 1
These models will be based on the existing 14/17/21 cabinets but will incorporate will incorporate new electronic control systems mounted in the new electronic control systems mounted in the door. door. Models Models FUF14SVRWW FUF14SVRWW FUF14DVRWW FUF14DVRWW FUF17SVRWW FUF17SVRWW FUF21SVRWW...
Electronic Temperature Control Electronic Temperature Control When the freezer is plugged in f When the freezer is plugged in for the first time, all LED’s will or the first time, all LED’s will turn on and the control will beep turn on and the control will beep three times.
Page 5
Set Points for Temperature Control Set Points for Temperature Control (ºF) (ºF) U U 2 2 1 1 F F ( ( M M o o d d e e l l 0 0 ) ) U U 1 1 7 7 F F ( ( M M o o d d e e l l 1 1 ) ) U U 1 1 4 4 F F ( ( M M o o d d e e l l 2 2 ) ) C C o o m p m p O O f f f f...
Turning the unit OFF and ON Turning the unit OFF and ON “0” “0” is displayed is displayed when the when the freezer is freezer is turned off. turned off. To tur To turn n the freezer off, the freezer off, press “Warmer” press “Warmer”...
Showroom Mode Showroom Mode Showroom Mode allows a person to demonstrate the freezer Showroom Mode allows a person to demonstrate the freezer features without turning on the compressor and fan or going features without turning on the compressor and fan or going through defro through defrost.
Page 11
Defrost Defrost Automatic Defrost Timing Automatic Defrost Timing After each 12 hours of accumulated compressor run time, After each 12 hours of accumulated compressor run time, 30 minute 30 minutes of defros s of defrost will be t will begin. gin.
Error Modes Error Modes If the thermistor is open, the display will alternate If the thermistor is open, the display will alternate between “E” between “E” and “9” and “9”. . If th If the ther e thermistor mistor is shor is shorted, ted, the display will alternate between “E”...
Service Mode Service Mode To enter the Service Mode, To enter the Service Mode, lock the control lock the control. This is done by . This is done by pressing pressing “Alarm Reset” “Alarm Reset” for for three seconds. three seconds. “ “ L L ” ” will then will then appear on the display for one second.
Page 17
Service Mode Continued Service Mode Continued After three seconds, the sequential information below will be displayed. After three seconds, the sequential information below will be displayed. Blank for 0.5 seconds. Blank for 0.5 seconds. Model Model ID ID for for 1 1 second, second, “...
Page 19
Service Mode Continued Service Mode Continued Thermistor status (“0 0 ” ” fo for o Thermistor status (“ r ope pen, n, “ “ C C ” ” fo for s r sho hort rt or or “-” “-”...