en | Operation with ICON LCD Codepad
5.1.5

Programming STAY Mode 2 Bypass Zones

Programming zones to be automatically isolated in STAY Mode 2 are only carried out if you
have a Master Code or Installer Code.
How to Program STAY Mode 2 Zones
1.
2.
3.
5.2
Disarming the System
When you enter the premises after the system is armed in AWAY mode, or if you armed the
system in STAY Mode 1 or STAY Mode 2, you must disarm the system to disable detection
devices that activate an alarm.
If there was an alarm condition prior to disarming the system, a flashing zone indicator
displays, indicating a previous alarm on that zone.
How to Disarm the System
Enter your user code followed by the [#] button (for example, [2580#]). Two beeps sound.
5.3
Arming/Disarming Areas
The control panel can be partitioned into two individual areas. User codes with authority levels
can arm/disarm each area or both areas from the area codepads.
This feature is only applicable if your installer assigned the zones, codepads,and user codes to
Area 1 , Area 2 or both areas.
How to arm both areas in AWAY Mode
This feature is only applicable if your installer programmed the user codes allowed to arm/
disarm both areas at same time.
Enter your user code followed by [0] and the [#] button ( for example, [25800#]). Two beeps
sound and the AWAY indicator displays. Exit Time starts counting.
How to disarm both areas
Enter your user code followed by [0] and the [#] button ( for example, [25800#]). Two beeps
sound and the AWAY indicator extinguishes.
How to arm Area 1 or Area 2 in AWAY Mode
Enter your user code followed by [0][1] and the [#] button ( for example, [258001#]) to arm
Area 1; or enter your user code followed by [0][2] and the [#] button ( for example,
[258002#]) to arm Area 2. Two beeps sound and the AWAY indicator displays. Exit Time starts
counting.
How to disarm Area 1 or Area 2 in AWAY Mode
Enter your user code followed by [0][1] and the [#] button ( for example, [258001#]) to
disarm Area 1; or enter your user code followed by [0][2] and the [#] button ( for example,
[258002#]) to disarm Area 2. Two beeps sound and the AWAY indicator extinguishes.
2017.09 | 04 | F.01U.298.028
Enter your Master Code or Installer Code, followed by [4] and the [#] button (for
example, followed [25804#]). Three beeps sound and the STAY indicator flashes.
Enter the zone number to be automatically isolated, followed by the [*] button (for
example, [1*] = Zone 1, [2*] = Zone 2). The selected zone flashes. If you make a mistake,
enter the same zone number followed by the [#] button to clear the incorrect zone. To
select additional zones to be automatically isolated in STAY Mode 2, repeat Step 2 as
many times as required.
Press the [#] button to exit this mode when you finish selecting all zones to be
automatically isolated in STAY Mode 2. Two beeps sound and the STAY and AWAY
indicators turn off.