beautypg.com
Manuals
Brands
Emerson Manuals
Industrial PC
Micro Motion 3711
Emerson Micro Motion 3711 Manuals
Manuals and User Guides for Emerson Micro Motion 3711. We have
1
Emerson Micro Motion 3711 manual available for free PDF download: Configuration And Use Manual
Emerson Micro Motion 3711 Configuration And Use Manual (234 pages)
Gas Flow Computers
Brand:
Emerson
| Category:
Industrial PC
| Size: 2.72 MB
Table of Contents
Table of Contents
3
Chapter 1 Before You Begin
9
Overview
9
Safety
9
About the Model 3711 Gas Flow Computer
9
Model 3711 System Components
9
User Programs
9
Implementation Overview
10
Communication Tools
10
Model 3711 Configuration Overview
10
Quick Start
10
Basic Configuration
11
Advanced Options
11
Model 3711 Administration Overview
12
Documentation Resources
12
Micro Motion Customer Service
12
Chapter 2 Getting Started
13
Overview
13
Starting the Model 3711
13
Installing ROCLINK 800
14
PC Requirements for ROCLINK 800
14
Using ROCLINK 800
15
Starting ROCLINK 800
15
ROCLINK 800 User Interface
15
TLP System
18
Configuration Files
19
Managing Device Configuration Files
19
Creating a New Device Configuration File
19
Setting up Devices and Groups
21
Device Configuration Backup and Duplication
21
First Connection to the Model 3711
21
Disconnecting and Closing
22
Chapter 3 System Configuration
23
Overview
23
Setting the Model 3711 Clock
23
Configuring Security
24
ROCLINK 800 Security
24
Device Security
25
Access Level
27
Configuring Model 3711 Device Information
29
Configuring Display Options
31
Setting up Communications
33
Overview
33
Communications Overview
33
Connecting to the Model 3711 through the LOI
34
Connecting to the Model 3711 through COMM 2
34
Using ROCLINK 800
34
Using a Host Program
35
Configuring Communications Parameters
35
Configuring COMM 2 on the Model 3711
35
Configuring ROCLINK 800 Communications Parameters
38
Configuring Communications for RBX Alarming
40
Configuring Passthrough Mode
42
Configuring the Core Interface
45
About this Chapter
45
Configuration Overview
45
Using ROCLINK 800 with the Micro Motion Core Interface
46
Core Interface Configuration Panels
46
Mass Flow Panel
46
Density Panel
48
Temperature Panel
49
Special Topics in Configuring the Core Interface
51
Characterization
51
Damping
52
Meter Factors
52
Slug Flow
53
Zeroing the Meter
54
Configuring Volumetric Flow Measurement
57
About this Chapter
57
Terminology
57
Configuration Overview
57
Input Defs Panel
57
Mass Compensation Panel
59
Gas Quality Panel
61
Advanced Panel
62
Sampler Panel
64
AO Assignment Panel
65
Alarms Panel
66
Chapter 7 Configuring I/O
69
About this Chapter
69
Overview
69
Configuring I/O Type
70
Configuring Analog Inputs
70
Filtering
71
Analog Input - General Panel
72
Analog Input - Advanced Panel
72
Analog Input - Alarms Panel
74
Configuring an Analog Output
75
Analog Output - General Panel
76
Analog Output - Advanced Panel
76
Configuring Discrete Inputs
78
Discrete Input - General Panel
78
Discrete Input - Advanced Panel
79
Discrete Input - Alarms Panel
80
Configuring the Discrete Outputs
82
Discrete Output - General Panel
82
Discrete Output - Advanced Panel
84
Discrete Output - TDO Parameters Panel
84
DOUT Type Options and Examples
86
Accuracy of Time Duration and TDO Toggle
86
Durations
86
Examples
86
Configuring Pulse Inputs
87
Pulse Input - General Panel
88
Pulse Input - Advanced Panel
89
Pulse Input - Alarms Panel
90
Managing History, Events, and Alarms
93
About this Chapter
93
Overview
93
History
93
Events and Alarms
93
Configuring History Points
94
Archive Types
96
Standard History Predefined Points
97
Using the Historical Databases
98
Viewing History Data
98
Viewing Alarm Logs and Event Logs
99
Using the Log Display Window
99
Monitoring and Displays
101
About this Chapter
101
Model 3711 Display Variables
101
Display Rules
101
Configuring Display Variables
102
ROCLINK 800 I/O Monitor
102
ROCLINK 800 Custom Displays
104
Creating a Custom Display
104
Saving and Loading Custom Displays
106
Editing a Custom Display
107
Using Custom Displays
107
Chapter 10 PID Control Loops
109
About this Chapter
109
PID Control Loops Overview
109
PID Control Loop Example
110
Configuring a PID Control Loop
110
Tuning the PID Control Loop
113
Monitoring the PID Control Loop
114
Configuration and Use Manual
115
Chapter 11 Function Sequence Tables
115
About this Chapter
115
FST Overview
115
Fsts and Model 3711 Points
116
FST Editor
116
Developing an FST
118
Monitoring and Tracing
123
Monitor Mode
123
Trace Mode and Debugging
125
Using Fsts
125
Saving, Reading and Downloading Fsts
125
Starting and Stopping Fsts
125
FST Storage and Restart
126
Deleting an FST
126
Printing and Exporting an FST
126
Editing an FST
126
Troubleshooting an FST
127
FST Command Library
127
Mathematical Commands
128
Logical Commands
129
Comparison Commands
131
Time-Related Commands
132
Control-Related Commands
133
Database Commands
134
Miscellaneous Commands
135
FST Examples
136
Example 1 - Writing Data to a History Point
136
Example 2 - Stopping an FST after Task Completion
137
Example 3 - Cycling an FST on a Periodic Basis
138
Example 4 - Calculate an Fst's Approximate Execution Rate
139
Chapter 12 Modbus Interface
141
About this Chapter
141
Overview
141
Modbus Overview
141
Modbus and Model 3711 Points
142
Configuring the Modbus Interface on the Model 3711
143
Modbus Scaling
148
Datatype Conversions
149
Modbus Register Ranges
152
Modbus Date and Time Formats
153
Accessing Model 3711 Data Via the Modbus Interface
153
Register Addresses
153
Accessing History Data
153
Accessing Event and Alarm Data
154
Chapter 13 Model 3711 Operator Interface
157
About this Chapter
157
Viewing Process Data and System Information
157
Using the Rates & Totals Windows
157
Using the Volumetric Flow Measurement Configuration Panels
159
Using the Core Interface Configuration Panels
159
Initial Calculations and Recalculations
161
Viewing Sensor Alarms and Communication Statistics
161
Reading and Writing to the Core Processor Modbus Interface
162
Chapter 14 Administration
165
About this Chapter
165
Initializing the Model 3711 and Managing Memory
165
Using the Jumpers
165
Using ROCLINK 800
166
Model 3711 Memory Structure
168
Meter Default Values
169
Event Log
170
Alarm Log
171
Advanced Communications and System Controls
171
Using the Optional Dial-Up Modem
172
Managing User Programs
172
14.10 Managing Device Configuration Files
173
Opening a Device Configuration File
173
Closing a Device Configuration File
174
Downloading a Device Configuration File to the Model 3711
174
14.11 Printing and Exporting a Device Configuration File
175
14.12 Updating Firmware and User Programs
175
Updating the Model 3711 Device Firmware
175
Updating the User Programs
177
14.13 Upgrading Hardware
178
Chapter 15 Maintenance and Troubleshooting
179
About this Chapter
179
Troubleshooting the Connection between ROCLINK 800 and the Model 3711
179
Debugging ROCLINK 800 Communications
179
Dial-Up Modem and FCC Compliance
180
Diagnostic Monitoring
181
Low Power Shutdown Mode
181
MPU Loading
181
Backup Battery
182
Automatic Self-Tests
182
15.10 Status Alarms
182
15.11 Checking Process Variables and Test Points
184
15.12 Checking Slug Flow
187
15.13 Checking the Characterization
187
15.14 Checking the Calibration
187
15.15 Diagnosing Wiring Problems
187
Checking the Power Supply Wiring
188
Checking the Sensor-To-Transmitter Wiring
188
Checking Grounding
188
15.16 Checking the Test Points
189
Evaluating the Test Points
189
Drive Gain Problems
189
Low Pickoff Voltage
190
15.17 Checking the Core Processor
190
Checking the Core Processor LED
190
Core Processor Resistance Test
191
15.18 Checking Sensor Pins
192
Remote Core Processor with Remote Transmitter Installation
192
4-Wire Remote Installation
194
Appendix A Installation Types and Components
197
About this Appendix
197
Installation Architectures
197
Remote Core Processor
198
I.S. Barrier
198
Termination Boards
199
Appendix B Calibration
201
About this Appendix
201
Calibrating an Analog Input or RTD
201
Preparing for Calibration
201
Calibration Procedure
201
Verification Procedure
203
Viewing Calibration Values for Analog Inputs or RTD
205
Calibrating the Analog Output
207
Density Calibration
207
Preparing for Calibration
207
Calibration Procedure
208
Appendix C Points and the TLP System
211
About this Appendix
211
Points
211
TLP System
211
Points
212
Logical Numbers
212
Parameters
213
Appendix D Soft Points
223
About this Appendix
223
Soft Point Overview
223
Configuring Soft Points
223
Appendix E Opcode Tables
225
About this Appendix
225
Opcode Table Overview
225
Configuring Opcode Tables
225
Index
227
Related Products
Emerson 399134018-KIT
Emerson 399393-01-0
Emerson 399381-01-1
Emerson 399381-02-0
Emerson Fisher 3710
Emerson Rosemount 375
Emerson Fisher 3722
Emerson Fisher 377
Emerson Rosemount 370XA
Emerson Micro Motion 3750
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals